Precautions
This package should contain the following items:
Required:
Optional:
The thermostat buttons and switches
The display
CAUTION
To prevent electrical shock and/or equipment damage, disconnect electrical power to the system at the main fuse or circuit breaker box, or by flipping a switch at the air handler. Do not restore power until installation is complete.
To ensure the power to your heating and cooling system has been turned off, try to turn on heating or cooling by changing the temperature on your old thermostat.
Remove the old thermostat’s front cover form the wall base. Some covers pull off easily, while others may need to be released by using a screwdriver.
Your old thermostat may have a sealed glass tube containing mercury. Be careful not to damage the tube or dispose of the tube in your trash. For safe disposal information.
Tip: Taking a picture with a camera or smartphone can help you not only remember how wires are connected to the terminals, but can also ensure that you label your wires correctly. Mislabeling the wires may result in a high energy bill or damage to your heating and cooling system.
For each wire that comes out of wall, follow these 4 steps.
Note that this step is very important for configuring your system in section 4.5. Please follow instruction carefully.
If your current terminal has the following letter | Write down that letter here | Label the wires with the following letters | Terminal function |
RH, R, R5, 5 | RH | 24V Power (Heating) | |
RC | RC | 24V Power (Cooling) | |
C, X, B* | C | Common Wire | |
W, W1, W/E, Aux/E, E | W/E | 1st Stage Heat (for conventional system); 1st Stage Auxiliary Heat (for heat pump system) |
If your current terminal has the following letter | Write down that letter here | Label the wires with the following letters | Terminal function |
W2** | W2 | 2nd Stage Heat (Conventional) 2nd Stage Auxiliary Heat (Heat Pump) | |
Y, Y1 | Y | 1st Stage Compressor | |
Y2 | Y2 | 2nd Stage compressor | |
G | G | Fan Relay | |
O, B*, O/B | O/B | Reversing Valve (for heat pump systems) | |
L | L | Heat Pump Diagnostic |
Do you have a “B” wire?
Labeling the “B” wire can be tricky. It could be labeled as “C” or “O/B” depending on whether you have an “O” wire connected to your old thermostat. Please pay attention and follow the asterisk (*) comments below while labeling it.
* Label “B” as “C” only if the old thermostat also had a wire in the “O” terminal block. If there was no wire in the “O” terminal block, label the wire as “O/B”
** On heat pump systems with separate W2 and E wires, label both wires W/E (2 wires on one terminal)
For terminal RC and RH:
On your old thermostat, if… | Then, on your new thermostat… |
Terminal RC and RH are connected with a jumper wire | Leave the RC/RH jumper wire in its place |
There’s only one R wire (RC, RH, R or R5) coming out of the wall | Leave the RC/RH jumper wire in its place |
Two separate R wires come out of the wall, and they are NOT connected by a jumper wire | Clip the jumper wire between RC and RH on the back of the new thermostat |
With all of your wires disconnected and properly labeled, you may now safely remove the thermostat base from your wall.
Tip: Worried about having your wires falling into your wall? Keep the wires secure by wrapping them around a pencil.
Thermostat Terminals with attached wires | Outdoor Equipment | Setting (Used in 4.5) | |
▢ | No wire on thermostat terminal Y | No air conditioner / no heat pump | AC0 |
▢ | Y (no O/B) | Single stage air conditioner | AC1 |
▢ | Y, Y2 (no O/B) | Two stage air conditioner | AC2 |
▢ | Y, O/B | Single stage heat pump | HP1 |
▢ | Y, Y2, O/B | Two stage heat pump | HP2 |
Thermostat Terminals with attached wires | Indoor Equipment | Setting (Used in 4.5) | |
▢ | No wire on thermostat terminal W/E | Blower only (no indoor heating equipment) | FAN |
▢ | W/E (Gas or Oil heat) | Single stage gas or oil furnace | GA1 |
▢ | W/E, W2 (Gas or Oil heat) | Two stage gas or oil furnace | GA2 |
▢ | W/E (Electric heat) | Single stage electric furnace | EL1 |
▢ | W/E, W2 (Electric heat) | Two stage electric furnace | EL2 |
User Menu # (Hold Menu 8 Seconds) | Description | Default Setting (flashing icons) | Settings (Press or ) |
05 | Outdoor Equipment: selects air conditioner (AC) or heat pump (HP) equipment as well as the number of stage |
AC2 | AC0 AC1 AC2 HP1 HP2 Refer to Section 4.3 |
10 | Indoor Equipment: selects whether the equipment is a gas furnace, electric furnace or fan only |
EL2 | FAN GA1 GA2 EL1 EL2 Refer to Section 4.3 |
20 R | Reversing valve set to O or B * * For heat pump systems only | O | O if old thermostat has an O terminal B if old thermostat has a B terminal |
30 CR | Heat Cycle Rate: how often the heat will turn on | MEd | SLO – slow MEd – medium FAS – fast |
User Menu # (Hold Menu 8 Seconds) | Description | Default Setting (flashing icons) | Settings (Press or ) |
32 CR | Aux Cycle Rate: how often the auxiliary heat will turn on | MEd | SLO – slow MEd – medium FAS – fast |
35 CR | Cool Cycle Rate: how often the cooling will turn on | MEd | SLO – slow MEd – medium FAS – fast |
50 CL | Compressor Lockout: protects the compressor from short cycling | OFF | On – 5 minute delay OFF – no delay |
65 | Max Heat Limit: maximum set point for heat mode | 99 | 47 to 99 |
66 | Minimum Cool Limit: minimum set point for cool mode | 45 | 45 to 97 |
Setting reversing valve is necessary for heat pump users only. Please refer to the chart in section 3.3 for your old thermostat’s wiring.
On your OLD thermostat
If your system does not have a G terminal connection, skip to 5.2 Heating system.
To customize thermostat settings, press the Menu button from the home screen. Use the
User Menu # (Press Menu button and release) | Description | Default Setting (flashing icons) | Settings (Press or ) |
01 | Fahrenheit or Celsius | °F | °F – Fahrenheit °C – Celsius |
02 | Temperature Display Adjustment: adjust the Room Temperature) | 0 | -5 to +5 |
03DL | Continuous Display Light: keep the backlight always on – “C” wire required | OFF | On – always on OFF – momentarily |
04 | Auto Changeover: Thermostat automatically switches between heat and cool | OFF | On – enable auto OFF – disable auto |
05 | Keypad Lock: prevent unwanted changes to the thermostat | OFF | On – disable buttons OFF – all buttons are active |
Electrical Rating:
Symptom | Possible Cause | Corrective Action |
No Heat/No Cool/No Fan (common problem) | 1. Blown fuse or tripped circuit breaker 2. Furnace power switch to OFF 3. Furnace blower compartment door or panel loose or not properly installed 4. Loose connection to thermostat or system | 1. Replace fuse or reset breaker. 2. Turn switch to ON. 3. Replace door panel in proper position to engage safety interlock or door switch. 4. Tighten connections |
No Heat | 1. System not set to Heat 2. Loose connection to thermostat or system 3. Heating System requires service or thermostat requires replacement | 1. Set thermostat to Heat. 2. Verify thermostat and system wires are securely attached. 3. Diagnostic: Set System to Heat and raise the setpoint above room temperature. Within five minutes the thermostat should make a soft click sound and “Heat On” should appear on display. |
Symptom | Possible Cause | Corrective Action |
No Heat (contd.) | 3. (contd.) This sound indicates the thermostat is operating properly.If the thermostat does not click, try the reset operation listed below. If the thermostat does not click after being reset, contact your heating and cooling service person or place of purchase for a replacement. If the thermostat clicks, contact the furnace manufacturer or a service person to verify the heating system is operating correctly. | |
No Cool | 1. System not set to Cool 2. Loose connection to thermostat or system 3. Cooling System requires service or thermostat requires replacement | 1. Set thermostat to Cool. 2. Verify thermostat and system wires are securely attached. 3. Diagnostic: Set System to Cool and lower setpoint below room temperature. Same procedures as diagnostic for “No Heat” condition except set the thermostat to Cool and lower the setpoint below the room temperature. There may be up to a five minute delay before the thermostat clicks in Cooling if the compressor lock-out option is selected in the installer menu. (see INSTALLER MENU, item 50) |
Symptom | Possible Cause | Corrective Action |
Heat, Cool or Fan Runs Constantly. | Possible short in wiring, thermostat, heat, cool or fan system | Check each wire connection to verify they are not shorted or touching other wires. Try resetting the thermostat. If the condition persists contact your HVAC service person. |
Thermostat Display & Thermometer Disagree | Thermostat display requires adjustment | Display can be adjusted +/-5°. See User Menu item 05 |
Furnace (Air Conditioner) Cycles Too Fast or Slow (narrow or wide temperature swing) | The location of the thermostat and/or the size of the Heating System may be influencing the cycle rate | Digital thermostats provide precise control and cycle faster than older mechanical models. The system turns on and off more frequently, but runs for a shorter time. If you would like to increase cycle time, choose SLO for slow cycle in the Installer menu. (Reference menu items 30, 32 & 35) If an acceptable cycle rate is not achieved, contact your HVAC service person. |
Symptom | Possible Cause | Corrective Action |
“Call for Service” icon appears on displayed | 1. Heating system is not able to heat the space to within 10 degrees of the setpoint within 2 hours 2. Cooling system is not able to cool the space to within 10 degrees of the setpoint within 2 hours 3. If “–” is displayed for the Room Tem- perature, a replacement thermostat is needed 4. None of the buttons operate on the thermostat 5. If “Call for Service” is flashing, com- pressor self diagnostic is detecting an issue with the outdoor unit | 1. See corrective action for “No Heat” 2. See corrective action for “No Cool” 3. Replace thermostat 4. Make sure keypad lockout is not turned on ( ), If it’s OFF, try reset shown below. 5. Contact a service person to verify the outdoor equipment is operating correctly |
Heat pump system runs heat in cool mode/cool in heat mode | Changeover “O/B” set incorrectly | Use configuration to switch “O” to “B” or “B” to “O” |
If the thermostat has good batteries, but has a blank display or does not respond to key presses, the thermostat should be reset by removing the batteries for 2 minutes. This reset will not change the menu settings or program.
If the condition persists after reinstalling the batteries, replace the thermostat.
To conveniently reset only the schedule and user settings back to factory defaults, press Menu and Backlight buttons at the same time and hold until the display goes blank and resets.
CONTACT US
Customer support: 877.654.9394 or wr.techsupport@emerson.com
MERCURY NOTICE
This product does not contain mercury. However, this product may replace a product that contains mercury.
Mercury and products containing mercury must not be discarded in household trash.
Refer to thermostat-recycle.org for location to send product containing mercury.
FOR CALIFORNIA RESIDENTS
Warning: This product contains a chemical known to the state of California to cause cancer and birth defects and other reproductive harm
Download Manual
Emerson White-Rodgers UNP310 Thermostat Installation User Manual
Emerson White-Rodgers UNP310 Thermostat Installation User Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…