If in doubt about whether your wiring is millivolt, line, or low voltage, have it inspected by a qualified heating and air conditioning contractor, electrician, or someone familiar with basic electricity and wiring. Do not exceed the specification ratings. All wiring must conform to local and national electrical codes and ordinances.
CAUTION
To prevent electrical shock and/or equipment damage, disconnect electric power to system, at main fuse or circuit breaker box, until installation is complete. Do not short out terminals on gas valve or primary control to test. Short or incorrect wiring will burn out thermostat and could cause personal injury and/or property damage. !
WHEN THIS THERMOSTAT IS CONNECTED TO SOME SYSTEMS THAT USE HIGH IMPEDANCE INPUT ELECTRONIC MODULES, YOU MAY OBSERVE THE FOLLOWING CONDITIONS.
If you observe any or all of these conditions after installing thermostat, you can correct system operation by installing isolation relays between the thermostat and the electronic ignition module. Figures 1 and 2 show how three isolation relays can be installed [one each for the fan (G), heat (W), and cool (Y)]. You may not need to install all three isolation relays to correct the operation conditions.
Figure 1 shows a single transformer heating/cooling system, with isolation relays installed in the heating (W), cooling (Y), and fan (G) circuits. To simplify the diagram, limit and safety switches are not shown here, although they will be found either in the low or high voltage circuit. Limit and safety switches must be retained. Refer to the equipment manufacturer’s system wiring diagram for the location of limit and safety switches.
! WARNING
DO NOT REMOVE OR WIRE AROUND LIMIT AND SAFETY SWITCHES WHEN INSTALLING ISOLATION RELAYS.
Figure 2 shows a two-transformer heating/cooling system, with isolation relays installed in the heating (W), cooling (Y), and fan (G) circuits. To simplify the diagram, limit and safety switches are not shown here, although they are found either in the low or high voltage circuit. Limit and safety switches must be retained. Refer to the equipment manufacturer’s system wiring diagram for the location of limit and safety switches.
WARNING
DO NOT REMOVE OR WIRE AROUND LIMIT AND SAFETY SWITCHES WHEN INSTALLING ISOLATION RELAYS.
Download Manual:
EMERSON White-Rodgers 1F90 Thermostat INSTALLATION INSTRUCTIONS
EMERSON White-Rodgers 1F90 Thermostat INSTALLATION INSTRUCTIONS
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…