Welcome
Thank you for your purchase.
Your new thermostat will provide uniform and comfortable temperature control throughout
every room in your property. We bring together technology, craftsmanship and the highest quality materials to provide you with a safe, reliable product combined with sleek, contemporary design. Please read this installation/programming manual for comprehensive instructions on installing and operating your thermostat. Please ensure a suitably qualified person installs your thermostat and complies with all local regulations.
Contents
Your thermostat carries an 24 month warranty from date of purchase. Service outwith the warranty period may incur a charge.
The THP1002 range has been developed to control electric underfloor or water heating or water/gas boiler system. These units are designed for use in commercial, industrial, civil and domestic properties.
You can set both the time temperature for each of these six daily periods. Adjusting/setting the schedules can only be carried out when in program mode; Touch
Default settings for program schedule
Time display | WEEKDAY (MON. – FRI.) | WEEKEND (SAT. – SUN.) | ||
TIME | TEMP. | TIME | TEMP. | |
Period 1 (Comfort) | 06.00 waken | 20°C | 06.00 waken | 20°C |
Period 2 (Economy) | 08.00 leave | 15°C | 08.00 leave | 20°C |
Period 3 (Comfort) | 11.30 home | 15°C | 11.30 home | 20°C |
Period 4 (Economy) | 13.30 leave | 15°C | 13.30 leave | 20°C |
Period 5 (Comfort) | 17.00 home | 22°C | 17.00 home | 15°C |
Period 6 (Economy) | 22.00 bed | 15°C | 22.00 bed | 15°C |
Default settings above assume a 5+2 (day) weekly program.
Please note:
With power off, press and hold both
Code | Function | Setting & options | Default |
1 | Air temperature calibration | Range is -9°C to +9°C for internal sensor | -2 |
2 |
Deadzone temperature |
1-5 ℃ |
1 |
3 | Button locking | 0: = All buttons will lock except the Power button 1: = All buttons will lock | 1 |
4 |
Sensor selection | In = control temperature using the internal sensor Ou = control temperature using the external (floor) sensor Al = control temperature using internal sensor to control temperature, and external sensor to limit the floor temperature Remark: Please make sure the right sensor. If choose the wrong or bad one, LCD will display Err. | In for GA/GC Al for GB |
5 | Minimum temperature setting | Range is 5°C – 15°C. | 05 |
6 | Maximum temperature setting | Range is 15°C – 45°C. | 35 |
7 | 12/24 hour clock | 0: 12h: = 12 Hour clock 1: 24h: = 24 hour clock | 1 |
8 | Display Mode | 0:display both set temp. and room temp. 1:display set temp. only | 0 |
9 | High temperature protection setting. | 25-70℃ | 45 |
Please note:
Your thermostat is suitable for installation within a standard 86mm pattress box or European 60mm
round pattress box.
Step 1. Keep power off.
RISK OF ELECTRICAL SHOCK. Disconnect/isolate power supply prior to making electrical connections. Contact with high voltage components can cause electrical shock, severe injury or death.
DOWNLOAD MANUALS:
Elechico THP1002 Programmable Room Thermostat Instructions Manuals
Elechico THP1002 Programmable Room Thermostat Instructions Manuals
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…