WELCOME!
If you have questions, we have answers.
Visit ecobee.com/support for tutorials, how-to videos and FAQs. Technical support is also available by email or by phone:
support@ecobee.com
1-866-518-6740
Smart Thermostat Premium works with most centralized residential heating and cooling systems.
IMPORTANT — TURN OFF THE POWER
Power off the HVAC system with the master switch or circuit breaker box.
WARNING! ecobee Smart Thermostat Premium is designed for 24VAC with a 2A maximum current. Do not connect it to line (high) voltage or millivolt systems.
CONVENTIONAL HEATING AND COOLING
(UP TO 2 STAGES EACH)
CONVENTIONAL HEATING AND COOLING
(WITH PEK)
NOTES:
HEAT PUMP (AIR OR GEOTHERMAL)
WITH AUXILIARY HEAT
NOTE: Heat pumps use an internet-based weather feed and do not require outdoor temp sensor and/or a dual-fuel kit.
PACKAGED TERMINAL AIR CONDITIONER
(PTAC) WITH MULTISPEED FAN
NOTE: G1, G2, G3 may also be labeled as GL, GM, GH
1-WIRE ACCESSORY
NOTE: Self-powered 24V accessories can be controlled using the ACC+ and ACC− terminals.
2-PIPE FAN COIL UNIT WITH AUX HEAT
(PIPE SENSORS OPTIONAL)
NOTE: G1, G2, G3 may also be labeled as GL, GM, GH
4-PIPE FAN COIL UNIT
NOTE: G1, G2, G3 may also be labeled as GL, GM, GH
BOILER OR RADIANT SYSTEM
THRESHOLD SETTINGS
Menu > Settings > Installation Settings > Thresholds
SETTING NAME | DESCRIPTION | DEFAULT |
Conventional & Heatpump Systems | ||
Auto Heat/Cool | In Auto mode, the thermostat will engage both your heating and cooling as necessary. | Enabled |
Heat/Cool Min Delta | The minimum temperature difference between the desired Heat and Cool set points in Auto mode. | 5F |
Configure Staging | Configure staging Manually, to select and customize values such as dissipation time, temperature deltas, and runtimes for both your heating and cooling equipment. (See *Manual Setting Options) | Automatic |
Compressor Min Cycle Off Time | The amount of time the compressor remains off between cycles. | 300 seconds |
Compressor Min Outdoor Temperature | The AC or Heatpump compressor will not run below this outdoor temperature. | AC – 35F / Heatpump – User defined |
AC Overcool Max | Will allow the air conditioner to overcool (above Cool set point) by this value to help decrease humidity. | Disabled |
Heat Min On Time | The minimum amount of time the furnace/boiler will stay on during a call for heat. | 5 minutes |
Compressor Min On Time | The minimum amount of time the compressor will stay on. | 5 minutes |
Temperature Correction | If the thermostat sensor reading is incorrect, a correction may be applied to achieve an accurate reading. | +0F |
Humidity Correction | If the thermostat sensor reading is incorrect, a correction may be applied to achieve an accurate reading. | +0% |
Thermal Protect | The minimum temperature reading difference between sensors that will trigger the algorithm to ignore the inaccurate sensor reading. | Disabled |
Installer Code | When enabled, this restricts access to Installation Settings (Code 3262 permits access) | Disabled |
Heatpump only Systems | ||
Aux Savings Optimization | This setting simplifies Heatpump to Aux Heating staging based on Savings vs. Comfort. The higher the temperature setting will sacrifice comfort for savings. | 2F |
Aux Heat Max Outdoor Temperature | The Auxiliary Heat will not run above this outdoor temperature. | 35F |
Aux Min On Time | The minimum amount of time your auxiliary heat will stay on during a call for aux heat. | 5 minutes |
Compressor To Aux Temperature Delta | The minimum number of degrees from the current temperature vs. set point before engaging the auxiliary heat. | Auto |
Compressor to Aux Runtime | The minimum number of minutes the Heatpump compressor will run for before switching to auxiliary heat. | Auto |
Aux Reverse Staging | When enabled, aux heat will be engaged if the current temperature is greater than the value designated in the Compressor to Aux Temperature Delta setting. | Off |
*Manual Setting Options | ||
Heat Differential Temperature | The minimum temperature differential before engaging heating. | 0.5F |
Heat Dissipation Time | The amount of time the fan will continue to run once the heating cycle is completed. | Auto |
Cool Differential Temperature | The minimum temperature differential before engaging cooling. | Auto |
Cool Dissipation Time | The amount of time the fan will continue to run once the cooling cycle is completed. | Auto |
Compressor Reverse Staging | When enabled, second stage compressor will be engaged if the current temperature is greater than the value designated in the Compressor Stage 2 Temperature Delta setting. | Off |
Compressor Stage 2 Temperature Delta | The minimum number of degrees from the current temperature vs. set point before engaging the second stage of the compressor. | Auto |
Compressor Stage 1 Max Runtime | The maximum number of minutes running stage 1 before engaging the second stage of the compressor. | Auto |
Heat Reverse Staging | When enabled, second stage heat will be engaged if the current temperature is greater than the value designated in the Heat Stage 2 Temp Delta setting. | Off |
Heat Stage 2 Temp Delta | The minimum number of degrees from desired setpoint before engaging the 2nd stage of heat. | Auto |
Heat Stage 1 Max Runtime | The maximum number of minutes running stage 1 before engaging the second stage heating. | Auto |
SETTING NAME | DESCRIPTION | DEFAULT |
Humidifier | ||
Evaporative or Steam | An ‘Evaporative’ humidifier will operate with a heating cycle where an ‘Steam’ humidifier can operate with/without a heating cycle. | User defined |
Min Runtime Delta | The humidifier will run beyond the desired humidity setpoint by the selected amount | 5% |
Window Efficiency | The Frost Control setting uses the efficiency rating to determine the desired humidity within the range of 15 to 50%. | 2 |
Dehumidifier | ||
Dehumidify with Fan | When enabled, this will activate the furnace/air-handler fan during a call for Dehumidification. | Yes |
Min Runtime Delta | The dehumidifier will run beyond the desired humidity setpoint by the selected amount | 5% |
Dehumidify in Heat Mode | Will permit the Dehumidifier to operate independent of a heating cycle. | No |
Dehumidifier Active | This setting is dependent whether the HVAC system or Dehumidifier requires it to be open or closed while active. | User defined |
Ventilator | ||
Pre-Occupancy Purge | Enable to run ventilator for 1 hour prior to expected occupancy | Disabled |
Free Cooling Max Outdoor Temperature | Free Cooling will not run when the outdoor temperature is above this point | 72F |
Free Cooling Max Outdoor Temperature | Maximum Outdoor Humidity to permit Free Cooling to run | Disabled |
Indoor/Outdoor Temperature Delta | Permit Free Cooling if Indoor Temp vs. Outdoor Temp is greater than Temperature Delta | 2F |
Max Desired Temperature Delta | Maximum delta between current and desired temperature to engage Free Cooling | Disabled |
Pre-Occupancy Purge | Enable to run ventilator for 1 hour prior to expected occupancy | Disabled |
SETTING NAME | DESCRIPTION | DEFAULT |
HVAC Maintenance | Maintenance interval for the heating & cooling systems. | Enabled, 6 months |
Furnace Filter | The frequency of filter reminders based on months or runtime hours. | Enabled, 3 months |
UV Lamp | The frequency when maintenance is needed based on months or runtime hours. | Disabled |
Low Temp Alert | When indoor temperature meets/exceeds this setting an alert will be generated. | Enabled, 50F |
High Temp Alert | When indoor temperature meets/exceeds this setting an alert will be generated. | Enabled, 92F |
Aux Outdoor Temp Alert | An alert will be generated when Aux Heat is used at this value or above. | Disabled |
Aux Heat Runtime Alert | An alert will be generated when Aux Heat meets/exceeds this runtime value in a 24hr period. | Disabled |
Low Humidity Alert | An alert will be generated if humidity falls below this value. | Disabled |
High Humidity Alert | An alert will be generated if the humidity rises above this value. | Disabled |
Display Alerts on Thermostat | When enabled, Alerts will also appear on the thermostat display. | Disabled |
Enable Heating/Cooling Alerts | An alert will be generated indicating that the system has failed to heat or cool the indoor location. | Enabled |
Download manual: ecobee Smart Premium Thermostat User Guide
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…