Ecobee

ecobee Smart Premium Thermostat User Guide

ecobee Smart Premium Thermostat

WELCOME!
If you have questions, we have answers.
Visit ecobee.com/support for tutorials, how-to videos and FAQs. Technical support is also available by email or by phone:
support@ecobee.com
1-866-518-6740

COMPATIBLE SYSTEMS

Smart Thermostat Premium works with most centralized residential heating and cooling systems.

  • Heating: Up to 2 stages
  • Cooling: Up to 2 stages
  • Heat pumps: Air, Water, and Geothermal with up to 2 stages, and 2 stages of AUX heat. Accessories: Dehumidifier, humidifier, or ventilation device.
  • Fan coil units: 2- and 4-Pipe with up to 3 fan speeds. Pipe sensors supported.
  • Packaged Terminal Air Conditioners (PTAC): Up to 3 fan speeds

IMPORTANT — TURN OFF THE POWER
Power off the HVAC system with the master switch or circuit breaker box.
WARNING! ecobee Smart Thermostat Premium is designed for 24VAC with a 2A maximum current. Do not connect it to line (high) voltage or millivolt systems.

TERMINAL DESCRIPTIONS

  • G Fan
  • Rc Cool transformer
  • Rh Heat transformer
  • O/B Heat pump reversing valve
  • Y1, Y2 Used for 1-2 stages of conventional A/C or 1-2 stages of heat pump compressor
  • W1, W2 Used for 1-2 stages of conventional heat or 1-2 stages of auxiliary heat with heat pump
  • C 24VAC common
  • ACC+/– Used for dehumidifiers, humidifiers, ventilators, HRVs or ERVs
  • PEK+ Power Extender Kit (PEK), which extends a C-wire when a physical wire is not available. PEK sold separately for Pro Builder models.

CONVENTIONAL HEATING AND COOLING
(UP TO 2 STAGES EACH)

CONVENTIONAL HEATING AND COOLING
(WITH PEK)

NOTES:

  1. When using a PEK with a heat pump system, the O/B terminal is wired directly to the thermostat.
  2. The PEK is not compatible with dual transformer or fan coil units.

HEAT PUMP (AIR OR GEOTHERMAL)
WITH AUXILIARY HEAT

NOTE: Heat pumps use an internet-based weather feed and do not require outdoor temp sensor and/or a dual-fuel kit.

PACKAGED TERMINAL AIR CONDITIONER
(PTAC) WITH MULTISPEED FAN

NOTE: G1, G2, G3 may also be labeled as GL, GM, GH

1-WIRE ACCESSORY

NOTE: Self-powered 24V accessories can be controlled using the ACC+ and ACC− terminals.

2-PIPE FAN COIL UNIT WITH AUX HEAT
(PIPE SENSORS OPTIONAL)

NOTE: G1, G2, G3 may also be labeled as GL, GM, GH

4-PIPE FAN COIL UNIT

NOTE: G1, G2, G3 may also be labeled as GL, GM, GH

BOILER OR RADIANT SYSTEM

Installation Settings

THRESHOLD SETTINGS
Menu > Settings > Installation Settings > Thresholds

SETTING NAME DESCRIPTION DEFAULT
Conventional & Heatpump Systems
Auto Heat/Cool In Auto mode, the thermostat will engage both your heating and cooling as necessary. Enabled
Heat/Cool Min Delta The minimum temperature difference between the desired Heat and Cool set points in Auto mode. 5F

Configure Staging

Configure staging Manually, to select and customize values such as dissipation time, temperature deltas, and runtimes for both your heating and cooling equipment. (See *Manual Setting Options)

Automatic

Compressor Min Cycle Off Time The amount of time the compressor remains off between cycles. 300 seconds
Compressor Min Outdoor Temperature

The AC or Heatpump compressor will not run below this outdoor temperature.

AC – 35F /

Heatpump – User defined

AC Overcool Max Will allow the air conditioner to overcool (above Cool set point) by this value to help decrease humidity. Disabled
Heat Min On Time The minimum amount of time the furnace/boiler will stay on during a call for heat. 5 minutes
Compressor Min On Time The minimum amount of time the compressor will stay on. 5 minutes
Temperature Correction If the thermostat sensor reading is incorrect, a correction may be applied to achieve an accurate reading. +0F
Humidity Correction If the thermostat sensor reading is incorrect, a correction may be applied to achieve an accurate reading. +0%
Thermal Protect The minimum temperature reading difference between sensors that will trigger the algorithm to ignore the inaccurate sensor reading. Disabled
Installer Code When enabled, this restricts access to Installation Settings (Code 3262 permits access) Disabled
Heatpump only Systems
Aux Savings Optimization This setting simplifies Heatpump to Aux Heating staging based on Savings vs. Comfort. The higher the temperature setting will sacrifice comfort for savings. 2F
Aux Heat Max Outdoor Temperature The Auxiliary Heat will not run above this outdoor temperature. 35F
Aux Min On Time The minimum amount of time your auxiliary heat will stay on during a call for aux heat. 5 minutes
Compressor To Aux Temperature Delta The minimum number of degrees from the current temperature vs. set point before engaging the auxiliary heat. Auto
Compressor to Aux Runtime The minimum number of minutes the Heatpump compressor will run for before switching to auxiliary heat. Auto
Aux Reverse Staging When enabled, aux heat will be engaged if the current temperature is greater than the value designated in the Compressor to Aux Temperature Delta setting. Off
*Manual Setting Options
Heat Differential Temperature The minimum temperature differential before engaging heating. 0.5F
Heat Dissipation Time The amount of time the fan will continue to run once the heating cycle is completed. Auto
Cool Differential Temperature The minimum temperature differential before engaging cooling. Auto
Cool Dissipation Time The amount of time the fan will continue to run once the cooling cycle is completed. Auto
Compressor Reverse Staging When enabled, second stage compressor will be engaged if the current temperature is greater than the value designated in the Compressor Stage 2 Temperature Delta setting. Off
Compressor Stage 2 Temperature Delta The minimum number of degrees from the current temperature vs. set point before engaging the second stage of the compressor. Auto
Compressor Stage 1 Max Runtime The maximum number of minutes running stage 1 before engaging the second stage of the compressor. Auto
Heat Reverse Staging When enabled, second stage heat will be engaged if the current temperature is greater than the value designated in the Heat Stage 2 Temp Delta setting. Off
Heat Stage 2 Temp Delta The minimum number of degrees from desired setpoint before engaging the 2nd stage of heat. Auto
Heat Stage 1 Max Runtime The maximum number of minutes running stage 1 before engaging the second stage heating. Auto

ACCESSORY SETTINGS

SETTING NAME DESCRIPTION DEFAULT
Humidifier
Evaporative or Steam An ‘Evaporative’ humidifier will operate with a heating cycle where an ‘Steam’ humidifier can operate with/without a heating cycle. User defined
Min Runtime Delta The humidifier will run beyond the desired humidity setpoint by the selected amount 5%
Window Efficiency The Frost Control setting uses the efficiency rating to determine the desired humidity within the range of 15 to 50%. 2
Dehumidifier
Dehumidify with Fan When enabled, this will activate the furnace/air-handler fan during a call for Dehumidification. Yes
Min Runtime Delta The dehumidifier will run beyond the desired humidity setpoint by the selected amount 5%
Dehumidify in Heat Mode Will permit the Dehumidifier to operate independent of a heating cycle. No
Dehumidifier Active This setting is dependent whether the HVAC system or Dehumidifier requires it to be open or closed while active. User defined
Ventilator
Pre-Occupancy Purge Enable to run ventilator for 1 hour prior to expected occupancy Disabled
Free Cooling Max Outdoor Temperature Free Cooling will not run when the outdoor temperature is above this point 72F
Free Cooling Max Outdoor Temperature Maximum Outdoor Humidity to permit Free Cooling to run Disabled
Indoor/Outdoor Temperature Delta Permit Free Cooling if Indoor Temp vs. Outdoor Temp is greater than Temperature Delta 2F
Max Desired Temperature Delta Maximum delta between current and desired temperature to engage Free Cooling Disabled
Pre-Occupancy Purge Enable to run ventilator for 1 hour prior to expected occupancy Disabled

REMINDERS & ALERTS SETTINGS

SETTING NAME DESCRIPTION DEFAULT
HVAC Maintenance Maintenance interval for the heating & cooling systems. Enabled, 6 months
Furnace Filter The frequency of filter reminders based on months or runtime hours. Enabled, 3 months
UV Lamp The frequency when maintenance is needed based on months or runtime hours. Disabled
Low Temp Alert When indoor temperature meets/exceeds this setting an alert will be generated. Enabled, 50F
High Temp Alert When indoor temperature meets/exceeds this setting an alert will be generated. Enabled, 92F
Aux Outdoor Temp Alert An alert will be generated when Aux Heat is used at this value or above. Disabled
Aux Heat Runtime Alert An alert will be generated when Aux Heat meets/exceeds this runtime value in a 24hr period. Disabled
Low Humidity Alert An alert will be generated if humidity falls below this value. Disabled
High Humidity Alert An alert will be generated if the humidity rises above this value. Disabled
Display Alerts on Thermostat When enabled, Alerts will also appear on the thermostat display. Disabled
Enable Heating/Cooling Alerts An alert will be generated indicating that the system has failed to heat or cool the indoor location. Enabled

Reference

Download manual: ecobee Smart Premium Thermostat User Guide

ecobee Smart Premium Thermostat User Guide

wpx_thermostats

Recent Posts

Johnson Controls T7000e LCD Digital Thermostat Installation Guide

Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide

1 year ago

Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’S GUIDE

Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE

1 year ago

Hetta HS01RF WIRELESS THERMOSTAT KIT USER MANUAL

Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…

1 year ago

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat USER MANUAL

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…

1 year ago

Honeywell RLV450 PROGRAMMABLE THERMOSTAT USER GUIDE

Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…

1 year ago

Honeywell RLV431 Programmable Thermostat User Guide

Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…

1 year ago