The thermostat should be mounted on an inner wall 1.5m above the floor in position where it is readily affected by changes of the general room temperature with freely circulating air. Prevent direct exposure to sunlight; dripping or splashing area. Do not place this unit at a location where air circulation is low, or where it has great temperature changes (e.g. near door). Do not place the thermostat near heat generating sources (radiators, hot air vents, TV or lights).
For Model PLVT1, there are 6 wiring terminals at the back of the thermostat which are labeled as “C”, “Y” and “G”, “Rc”, “R” and “O/W B”.
B. Start/Reset:
Normal Display Mode:
Temperature Setting Display Mode:
To adjust heat/cool setting:
Internal Mode Setting Display:
| Mode type | Function type | Setting | |||
|
HO | Heat only (normal-open or normal-close valves) | HS | Span of Heater | 1 °C / 2°F | |
| 2 °C/ 4°F | |||||
| dU | Temperature Display Unit | °C | |||
| °F | |||||
|
HF |
Heat with fan | HS | Span of Heater | 1 °C/ 2°F | |
| 2 °C/ 4°F | |||||
| dU | Temperature Display Unit | °C | |||
| °F | |||||
| FC | Fan Control method | O | Gas or oil furnace – equipment controls fan | ||
| E | Electric furnace – thermostat controls fan | ||||
|
CL |
Cool | dU | Temperature Display Unit | °C | |
| °F | |||||
| CS | Span of Cool | 1°C/ 2°F | |||
| 2°C/ 4°F | |||||
|
Cd | Compressor Minimum-Off Delay | 1 | 1 minute compressor off delay | ||
| 2 | 2 minute compressor off delay | ||||
| 3 | 3 minute compressor off delay | ||||
| 4 | 4 minute compressor off delay | ||||
| 5 | 5 minute compressor off delay | ||||
|
HP |
Heat pump | HS | Span of Heater | 1°C/ 2°F | |
| 2 °C/ 4°F | |||||
| CO | Changeover Valve | C | O/B terminal energized in cooling (default) | ||
| H | O/B terminal energized in heating | ||||
| dU | Temperature Display Unit | °C | |||
| °F | |||||
| CS | Span of Cool | 1°C/ 2°F | |||
| 2°C/ 4°F | |||||
|
Cd | Compressor/ Heater Minimum-Off Delay | 1 | 1 minute compressor off delay | ||
| 2 | 2 minute compressor off delay | ||||
| 3 | 3 minute compressor off delay | ||||
| 4 | 4 minute compressor off delay | ||||
| 5 | 5 minute compressor off delay | ||||
| SL | Mode Adjustment | 1 | Heat, Cool Off Selectable | ||
| 2 | Auto, off Selectable | ||||
| 3 | Heat, Cool Off, Auto Selectable | ||||
|
HC |
Electric/oil/gas heat with cool (Default setting) | HS | Span of Heater | 1°C/ 2°F (Default setting) | |
| 2 °C/ 4°F | |||||
| dU | Temperature Display Unit | ° C (Default setting) | |||
| °F | |||||
| CS | Span of Cool | 1°C/ 2°F (Default setting) | |||
| 2°C/ 4°F | |||||
|
Cd |
Compressor Minimum-Off Delay | 1 | 1 minute compressor off delay | ||
| 2 | 2 minute compressor off delay | ||||
| 3 | 3 minute compressor off delay | ||||
| 4 | 4 minute compressor off delay (Default setting) | ||||
| 5 | 5 minute compressor off delay | ||||
| SL | Mode Adjustment | 1 | Heat, Cool, Off Selectable | ||
| 2 | Auto, off Selectable | ||||
| 3 | Heat, Cool Off, Auto Selectable (Default setting) | ||||
|
FC |
Fan Control Method | O | Gas or oil furnace – equipment controls fan | ||
| E | Electric furnace – thermostat controls fan (Default setting) | ||||
Description of the mode types:
Replaceable Batteries Instruction:
Caution: Switch off the electric source before maintenancing the thermostat. We recommend that the maintenance should be performed by trained personnel.
No heating/ cooling control
DOWNLOAD MANUALS:
DWYER PLVT1 Digital Programmable Thermostat Installation Manual
DWYER PLVT1 Digital Programmable Thermostat Installation Manual
Bremerhaven Casino No Deposit Bonus Codes For Free Spins 2026 The customer support team isnt…
Legal Casino Online You must provide a mailing address and social security digits to complete…
Real Cash Online Casino United Kingdom Mega Fortune is also a bit unusual in the…
Amex Casino United Kingdom Instead of free spins, you do well and have winnings that…
Best Online Casino For Roulette Time and Again is an HTML5 title, best online casino…
Fastest Payout Online Casinos Bally Wulff is known for their amazing classic slots and Back…