INTRODUCTION

The Digistat+ CRF cylinder thermostat controls the domestic hot water temperature to suit your lifestyle and gives energy savings when set between the recommended 60ºC to 65ºC.

  • User adjustable Min/Max temperature setting
  • Digital display situated above dial for ease of reading

Features

  • Conventional dial adjustment Tactile dial
  • 5ºC setting steps
  • Tactile & audible feedback via click of the dial
  • Visual feedback via digital display
  • Min/Max temperature setting
  • Battery powered
  • Digital display situated above dial for ease of reading

Wiring

Getting Technical

Model: Digistat +CRF SCR (receiver)
Power supply: 2 X 1.5V IEC LR6(AA) alkaline batteries 230V a.c. 50Hz
Switch type and rating: N/A SPDT (voltage free) 2(1)A 230V a.c. or 24V a.c../d.c

Wiring:

Designed for fixed wiring only, to comply with current IET wiring regulations (BS7671). Ø 0.5mm² 2 core cable between sensor and thermostat

Mounting:

Thermostat: Suitable for surface or conduit box mounting

Sensor: Direct mounting onto cylinder

Industry standard wall plate

Battery life: 2 years typical N/A
Ambient temperature: Operating 0°C to 50°C / Storage – 20°C to 55°C
Ambient humidity (non condensing): Operating 25% to 90% / Storage 15% to 95%
Temperature range: 40°C to 70°C
Control accuracy: +0/-8ºC
Control algorithm: On / Off
Temperature resolution: 5°C
Ball pressure test: 75°C
Pollution situation: Degree 2
Protection level: IP30
Pollution class: 2
Software class: A
Radio frequency: 433 MHz
Radio signal range: 30m typically. The range may be affected by the composition / density and number of walls between the thermostat and receiver.

Relevant directives:

2014/53/EU Radio Equipment Directive Batteries Directive 2006/66/EC, 2011/65/EU RoHS Directive
Applied standards: EN60730-1; EN60730-2-9 EN 300 220-2; EN 301 489-3

Digistat+C RF

Product Part No.
Digistat+CRF cylinder thermostat & SCR & sensor 13616
Digistat+CRF SCR receiver spare 22598
Digistat+CRF transmitter spare 13618
Digistat+CRF thermostat spare 13619

REFERENCE

DOWNLOAD MANUAL:

Drayton Digistat +CRF 13616 Cylinder Thermostat Product Specifications Guide

Other manuals:

Drayton Digistat +CRF 13616 Cylinder Thermostat Installation Guide

Drayton Digistat +CRF 13616 Cylinder Thermostat USER Guide

Drayton Digistat +CRF 13616 Cylinder Thermostat Product Specifications Guide

wpx_thermostats

Recent Posts

Johnson Controls T7000e LCD Digital Thermostat Installation Guide

Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide

2 years ago

Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’S GUIDE

Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE

2 years ago

Hetta HS01RF WIRELESS THERMOSTAT KIT USER MANUAL

Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…

2 years ago

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat USER MANUAL

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…

2 years ago

Honeywell RLV450 PROGRAMMABLE THERMOSTAT USER GUIDE

Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…

2 years ago

Honeywell RLV431 Programmable Thermostat User Guide

Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…

2 years ago