Drayton

Drayton Digistat +2RF/+3RF Programmable Room Thermostat QUICK START GUIDE

Drayton Digistat +2RF/+3RF Programmable Room Thermostat

Drayton Digistat +3 and +3RF

The Digistat +3/+3RF thermostat is a programmable thermostat with 5-2 Day or 7 day timings and 6 time/temperature events during the day.

Clock Setting

Your Digistat +3/+3RF is fitted with a “real-time clock”, which is “pre-set” at the factory; you will not have to alter the time settings. A special feature of this real-time clock is it will automatically change over during the GMT/BST summer/winter change over removing the need to manually alter the clock.

General Operation

Programmable thermostats do not have “On” and “Off” times like traditional timers. They offer temperature control both day and night and you simply select which temperatures you require at which times of the day. With the unit in “Auto-Mode” (the small arrow to bottom of screen will point to Auto) the temperature can be changed for a short time by using the buttons. Changing the temperature in this way will keep the Digistat +3/+3RF set to your new temperature until the next pre-programmed event (at which time it will revert to the programmed temperature). The temperature you are setting will flash on the screen. Once the temperature is set, the unit will revert to showing the room temperature. The indicator will show on the screen if the heating is calling for heat.

Programming

Programming the Digistat +3/+3RF

Your Digistat +3/+3RF comes with the following settings pre-programmed for your convenience:
Pre-set program 1 (9 til 5) WEEKDAY

Event 1 2 3 4 5 6
Time 6:30 8:30 12:00 14:00 16:30 22:30
Temperature 20.0 16.0 16.0 16.0 21.0 7.0

As you can see, at 06:30, the heating will come on to raise the temperature to 20ºC. At 8.30, the temperature set point is dropped from 20ºC down to 16ºC, at which time it stays at 16ºC throughout the day, until 16:30 when the temperature increases to 21ºC. The temperature then drops down to a night-setback temperature of 7ºC until 06:30 when the cycle repeats for the next day (Monday to Friday) or changes to weekend settings see below.

Pre-set program 1 (9 til 5) WEEKEND

Event 1 2 3 4 5 6
Time 7:o0 9:00 12:00 14:00 16:00 23:30
Temperature 20.0 18.0 21.0 18.0 21.0 7.0

As you can see, at 07:00, the heating will come on to raise the temperature to 20ºC. At 9.00, the temperature set point is dropped from 20ºC down to 18ºC, it stays at 18ºC until 12.00 when the heating comes to raise the temperature to 21ºC. The temperature stays at 21ºC until 14.00 when it drops down to 18ºC. at 16.30 the heating comes on to raise the temperature to 21ºC where it stays until 23.00 when the temperature then drops down to a night-setback temperature of 7ºC until 07.00 when the cycle repeats for the next day (Saturday and Sunday) or changes to weekday settings see above.

TO ADJUST THE TIMES AND TEMPERATURES FOR 7-DAY OPERATION:

 

1. With the product operating as normal in the “Auto” mode, press  once and then press the button until the display is flashing and shows.

2. Press the once, the display will be as shown. The time will be flashing, use the     buttons to adjust the 1st time as required.

3. Once time has been set, pressand use the buttons to adjust required temperature. Repeat the above steps 7-8 until the 6 periods have been set for Monday.

4. Once Monday has been set, press once. Repeat steps 7-8 until all 7 days of the week have been set.
5. Once the final temperature has been set press the to confirm settings. To exit pressuntil you return to auto mode with the bottom arrow pointing at Auto.

TO ADJUST THE TIMES AND TEMPERATURES FOR 5-2 DAY OPERATION:

1. With the product operating as normal in the Auto mode press once and then press the button until the display is flashing and shows:

 

2. Press the button once, the display will be as shown. The time will be flashing, use the button to adjust the 1st time as required.

3. Once time has been set, press and use the button to adjust required temperature (shown flashing). Press to confirm and move to the next time and temperature periods to be adjusted confirming changes by pressing          (max. 6 periods).

4. Once the last weekday temperature period has been set, pressonce to confirm settings and allow adjustment of the weekend program.

Use the  buttons and the button to set the 6 periods for the weekend program.

5. Once the final temperature has been set press to confirm setting. To exit press  until you return to auto mode with the bottom arrow pointing at Auto.

other manuals:

 Drayton Digistat +2RF/+3RF Programmable Room Thermostat Product Guide

Drayton Digistat +2RF/+3RF Programmable Room Thermostat Installation Instruction

Drayton Digistat +2RF/+3RF Programmable Room Thermostat QUICK START GUIDE

wpx_thermostats

Recent Posts

Johnson Controls T7000e LCD Digital Thermostat Installation Guide

Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide

2 years ago

Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’S GUIDE

Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE

2 years ago

Hetta HS01RF WIRELESS THERMOSTAT KIT USER MANUAL

Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…

2 years ago

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat USER MANUAL

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…

2 years ago

Honeywell RLV450 PROGRAMMABLE THERMOSTAT USER GUIDE

Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…

2 years ago

Honeywell RLV431 Programmable Thermostat User Guide

Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…

2 years ago