Drayton Digistat +2RF/+3RF Programmable Room Thermostat Product Guide

Drayton Digistat +2RF/+3RF Programmable Room Thermostat

BUILT FOR EASE

The Drayton wireless programmable thermostat systems have been designed to make your life easier. Installation couldn’t be simpler thanks to the reliable wireless technology and well loved familiar features.

  • Simple installation
  • Standard backplate for SCR
  • No wiring, no plasterwork to chase out
  • No re-decoration
  • Positioning not restricted by cable runs

BUILT TO BE VERSATILE
Both Digistat+2RF and +3RF have a range of features to make you, and your customer’s life, much easier.

FLEXIBLE FEATURES

  • On/off load compensation
  • 24hr, 5/2 day or 7 day programmes (Digistat+3RF)
  • Holiday mode
  • 12 or 24 hour clock
  • Intelligent delayed start option
  • Up to 6 time/temperature events per day
  • Suitable for combi boilers, hydronic underfloor and zoning

MAKING LIFE EASY

  • Easy temperature override
  • 4 button programming
  • Memory saver function
  • Auto summer/winter time updates
  • Pre-set clock

NEW Service interval features

  • Flexible service interval mode (reminder, reduced comfort or off)
  • Adjustable warning period
  • Adjustable service period
  • Visual indication on LCD
  • Selectable boost feature
  • Selectable audible alarm
  • Reset by installer selectable 4-digit code

SCR Receiver Wiring

HOW DO WE MEASURE UP?
Digistat+2RF/+3RF (transmitters)

WHAT’S THE DIFFERENCE BETWEEN A DIGISTAT+2RF AND +3RF?
Digistat+2RF allows you to set the same programme for every day of the week. Digistat+3RF gives you the option of setting a different programme for each day, or different programmes for weekends and week days.

PART NUMBERS

Products in range Part No. Si Part No.
Digistat+2RF (24hour) wireless system RF700 RF703
Digistat+3RF (5-2day/7day) wireless system RF701 RF704
Digistat+2RF (transmitter only) spare 22090 22111
Digistat+3RF (transmitter only) spare 22092 22110
Digistat+ SCR (receiver only) spare 22149 22149

TECHNICAL DATA

Digistat +2RF/+3RF SCR (receiver)
Power supply: 2 X 1.5V IEC LR6(AA)

alkaline batteries

230V a.c. 50Hz
Switch type and rating: N/A SPDT (voltage free) 2(1)A 230V a.c. or 24V a.c../d.c

Wiring:

No wiring required

Designed for fixed wiring only, to comply with current IET wiring regulations (BS7671).
Mounting: Suitable for surface or conduit box mounting Industry standard wall plate
Battery life: 2 years typical N/A
Ambient temperature: Operating 0°C to 40°C Storage – 20°C to 55°C
Ambient humidity(non condensing): Operating 25% to 90%

Storage 15% to 95%

Temperature range: 5°C to 32°C
Temperature resolution: 0.5°C
Control accuracy: + 0.5K @ 20ºC
Timing resolution: 1 minute
Ball pressure test: 75°C
Pollution degree: 2
Protection level: IP30
Software class: A
Radio frequency: 433 MHz

Radio signal range:

30m typically. The range may be affected by the composition / density and number of walls between the thermostat and receiver.
Energy class: IV = 2% (Acc. EU 811/2013, 812/2013, 813/2013, 814/2013)

Relevant EC directives:

2014/53/EU Radio Equipment Directive 2006/66/EC Batteries Directive 2011/65/EU RoHS Directive

Applied standards:

EN60730-1; EN60730-2-7; EN60730-2-9 EN 300 220-2; EN 301 489-3

9° NETWORK
Join our professional installer club today and benefit from extended guarantees, priority support and much more.
www.draytoncontrols.co.uk/9degrees

HEAR ALL THE NEWS @draytonheating
WATCH OUR VIDEOS /draytoncontrols

Customer Service Support

0333 6000 622
www.draytoncontrols.co.uk
customer.care@draytoncontrols.co.uk

D76-5
In accordance with our continuous improvement procedures, we reserve the right to change design features and specifications without prior notification. The Data contained in this document is for guidance only. Drayton accepts no liability for any consequential losses, injury or damage resulting from the use of this document or the information contained within.

Other Manuals

Drayton Digistat +2RF/+3RF Programmable Room Thermostat QUICK START GUIDE

Drayton Digistat +2RF/+3RF Programmable Room Thermostat Installation Instruction

Drayton Digistat +2RF/+3RF Programmable Room Thermostat Product Guide

wpx_thermostats

Recent Posts

Johnson Controls T7000e LCD Digital Thermostat Installation Guide

Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide

1 year ago

Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’S GUIDE

Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE

1 year ago

Hetta HS01RF WIRELESS THERMOSTAT KIT USER MANUAL

Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…

1 year ago

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat USER MANUAL

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…

1 year ago

Honeywell RLV450 PROGRAMMABLE THERMOSTAT USER GUIDE

Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…

1 year ago

Honeywell RLV431 Programmable Thermostat User Guide

Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…

1 year ago