WARNING
If you do not have the knowledge to install the SCR safely then you must arrange for a competent electrician to install it for you. Wiring must conform to the current IEE regulations. Prior to commencing the installation you must ensure the mains supply is switched off.
Read all installation and commissioning instructions before proceeding. Do not switch on until ready to commission.
The system wiring must be able to be fully disconnected from the mains supply by a switch incorporated in the fixed wiring having a contact separation of at least 3mm on both poles. Fused at 3A.
Location
The Digistat SCR (receiver) should be mounted in a convenient position, close to the combi boiler or central heating system wiring center. (Care should be taken not to mount the SCR in a position where it is surrounded by metal objects or mains voltage cable, as this may interfere with the radio signal). For the best performance install in an open space, at least 30cm distance from any metal objects including wall boxes and boiler housing. It is recommended that the SCR is mounted on the wall nearest the final location of the Digistat +RF room thermostat and not less than 30cm from the boiler side panel.
Warning: Installing the SCR too close to the metal side panel or main cables may interfere with the radio signal.
Fixing (minimum wall plate clearances shown)
This product is double-insulated and does not require an earth connection. The SCR should be wired to the combi boiler or central heating wiring using the correct type of cable or flex. The SCR should be wired in to replace hard-wired room or programmable thermostats shown on the system or boiler wiring diagrams. Always check other manufacturers’ instructions for compatibility.
Combi boiler basic wiring layout
Zone control basic wiring layout
Note: If the Digistat +2RF or +3RF is used without a separate programmer, or the programmer is set constantly on it would be acceptable to link ‘L’ to ‘1’ provided the output voltage required is 230V ac.
IMPORTANT: MULTIZONE INSTALLATIONS ONLY
If more than one ‘wireless system’ is fitted within the same property ie. for controlling 2 or more zones (multi-zone) it is essential that the Digistat +RF units are matched correctly to the relevant SCR. This is easily achieved by commissioning each Digistat +RF and SCR in turn.
The Digistat +2RF/+3RF is a radio frequency device and for best performance should be mounted in an open space, not less than 30cm distance from any metal objects, including wall boxes. Care should be taken to mount the Digistat +2RF/+3RF on a wall, in a postion which is not subject to direct sunlight or draughts. Preferably it should be mounted on an inside wall about 1.5m (5ft) above the floor in a position where it can respond to room temperature, but away from the direct influence of radiators or other appliances giving off heat.
Before fixing the Digistat +2RF/+3RF to the wall it is recommended to first check the signal strength from that location. To do this, remove the batteries, press and hold the + button whilst refitting the batteries. The display now shows rF which indicates that the Digistat +2RF/+3RF is continuously sending an OFF signal to the SCR (receiver). Leave the Digistat +2RF/+3RF in position and return to view the SCR. If the RED LED is continuously flashing, this indicates a good signal. If the RED LED is not flashing, this indicates a poor signal and you need to reposition the Digistat +2RF/+3RF until the RED LED is flashing. When the signal strength has been confirmed remove the batteries to cancel the test and follow the installation instructions 1-7 as follows.
If you wish to change any of the Installer Options as shown below, enter the Installer Option Menu from Auto mode by pressing < and + simultaneously for 5 seconds. Pressing < and + again for 5 seconds will exit the Menu and return to Auto mode. Once the Installer Options screen has been selected (Fig 7), the < and > buttons allow you to scroll through the Menu (shown below). The + and – allow you to change values. Once a value has been changed pressing > before exiting the Menu will save the new setting. (Fig 8 shows Option 02 OFF).
(Option 02)
Freeze protection will switch on the heating if the room temperature falls to 5ºC and will then control the temperature at 7ºC even if the Digistat+2RF/+3RF is in OFF mode. The Freeze Protection default in ON. To switch off the Freeze Protection mode enter the Installer Options Menu (Refer to Installer Options 02) and change to OFF. Press > to accept.
(Option 04 & 05)
Low and High Limit set points.
The user temperature set points defaults are High 32ºC and Low 5ºC, to change these limits enter the Installer Options Menu (Refer to Installer Options 04 & 05).
(Option 06)
Intelligent Delayed Start (Energy saving feature).
The Intelligent Delayed Start is an energy saving feature which automatically reduces the warm up time for the heating system. As the weather becomes milder, Intelligent Start will delay the heating start times so that fuel is not wasted bringing the room up to temperature earlier than necessary. Note: Intelligent Delayed Start only applies in Auto mode. Intelligent Delayed Start default is in OFF mode. To switch ON Intelligent Delayed Start enter the Installer Options Menu (Refer to Installer Options 06). Note the Intelligent Delayed start option is not suitable for Hydronic underfloor application. Ensure Installer option 06 is set to OFF before final commissioning for Hydronic underfloor application.
Special Note:
If the Intelligent delayed start feature is enabled, (Off changed to On in Installer option 06), please inform the end user of this feature.
The following special note has been added to the user instruction to explain the adjustment requirement:
When the delay period is operating indicated by the flame symbol flashing (Fig12), pressing any button returns the Digistat +2/3RF to auto mode allowing normal button operation until the next time/ temperature event, when it will resume the delay start mode or follows the Holiday, Manual, Override or Off modes as selected.
Changes to the installer options and pre-set programmes must be made with the flame symbol not flashing.
In some hydronic heating systems there may be a requirement to protect the valve by operating it once a day, for a given period, without bringing on the heating system. If valve protection is selected the valve will be operated for a period as shown in Valve protection time (mins). Valve protection time every day at 10.00am. Valve protection default is OFF.
To enable the valve protection mode enter the Installer Options Menu (Refer to Installer Option 10).
(Option 11)
Valve Protection time (mins).
Valve protection time can be set between 1 and 5 minutes (default 3 minutes).
To change this once a day on time enter the Installer Options Menu (Refer to Installer Option 11).
Digistat+2RF/+3RF can be used for different applications.
In the installer menu, select:
Adjust this setting to suit the heating system capability.
Digistat +RF Programmable Room Thermostats are available in 2 models.
Display Error code E1
When the display shows an error code (E1) this indicates a sensor fault and the heating system will remain Off. Please contact your local heating service engineer to replace your Digistat +2RF/3RFs
Power supply | 2 X 1.5V IEC LR6 (AA) alkaline batteries |
Battery life | 2 years typical |
Ambient temperature | Operating 0°C to 40°C Storage – 20°C to 55°C |
Ambient humidity (non condensing) | Operating 25% to 90% Storage 15% to 95% |
Temperature range | 5°C to 32°C |
Accuracy (between 5°C & 32°C) | 0.5K |
Timing resolution | 1 minute |
Temperature resolution | 0.5K |
Ball pressure test | 75 °C |
Pollution Degree | 2 |
Protection level | IP30 |
Energy Class | IV = 2% (According to EU 811/2013, 812/2013, 813/2013, 814/2013) |
Power Supply: | 230V ac 50Hz |
Switch Type & Rating: | SPDT (voltage free) 2(1)A 230V ac or 24V ac/dc |
Wiring: | Designed for fixed wiring only, to comply with current IEE regulations. (BS 7671) |
Temperature Range: | 40°C to 70°C |
Mounting: | Industry standard wallplate. |
Pollution Degree: | 2 |
Software Class: | A |
Rated Impulse Voltage: | 2.5Kv |
Ball Pressure Test: | 75°C |
Reception Frequency: | 433 MHz |
Relevant EC Directives: 2006/95/EC Low Voltage Directive
Applied Standards: EN60730-1 EN60730-2-7 EN60730-2-9 EN 300 220-2 EN 301 489-3
Drayton Digistat +2RF/+3RF Programmable Room Thermostat QUICK START GUIDE
Drayton Digistat +2RF/+3RF Programmable Room Thermostat Product Guide
Drayton Digistat +2RF/+3RF Programmable Room Thermostat Installation Instruction
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…