The English language is used for the original instructions. Other languages are a translation of the original instructions.(Directive 2006/42/EC)
DEVIreg™ 530 is an electronic thermostat provided with a 2-pole switch and a wire sensor to measure and control the desired floor temperature. It can be either flush-mounted
(standard) or surface-mounted (using special box). The thermostat has a button for adjusting the temperature setting with a scale from (
More information on this product can also be found at: devireg.devi.com
Operation voltage | 220-240V~, 50Hz |
Standby power consumption | Max 0.25W |
Relay: Resistive load Inductive load | Max 15A / 3450W @ 230V cos φ= 0.3 max 1A |
Sensing units | NTC 15kOhm at 25°C |
Sensing values: 0°C 25°C 50°C | 42 kOhm 15 kOhm 6 kOhm |
Hysteresis | ± 0.4°C |
Ambient temperature | -10 to +30°C |
Frost protection temperature | 5 °C – |
Temperature range | |
Cable specification max | 1x4mm² or 2×2,5mm² |
Ball pressure temperature | 75 °C |
Pollution degree | 2 (domestic use) |
Type | 1C |
Storage temperature | -20 to +65°C |
IP class | 31 |
Protection class | Class II – |
Dimensions | 85 x 85 x 36 mm |
Weight | 90 g |
The product complies with the EN/IEC Standard «Automatic electrical controls for household and similar use»:
Make sure the mains supply to the thermostat is turned off before installation.
IMPORTANT: When the thermostat is used to control a floor heating element in connection with a wooden floor or similar material, always use a floor sensor and never set the maximum floor temperature to more than 35°C.
Please also note the following:
Note: A floor sensor enables a more accurate temperature control and is recommended in all floor heating applications and mandatory under wooden floors to reduce the risk of over-heating the floor.
Follow the steps below to mount the thermostat:
How to change the minimum and maximum floor temperatures
Thermal resistance [m²K/W] | Examples of flooring | Details | Approximate setting for 25 °C on top surface of floor |
0.05 | 8 mm HDF based laminate | > 800 kg/m³ | 28˚C |
0.10 | 14 mm beech parquet | 650 – 800 kg/m³ | 31˚C |
0.13 | 22 mm solid oak plank | > 800 kg/m³ | 32˚C |
< 0.17 | Max. carpet thick- ness suitable for floor heating | acc. to EN/IEC 1307 | 34˚C |
0.18 | 22 mm solid fir planks | 450 – 650 kg/m³ | 35°C |
A 2-year product warranty is valid for: thermostats: DEVIreg™ 530.
Should you, against all expectations, experience a problem with your DEVI product, you will find that Danfoss offers DEVIwarranty valid from the date of purchase on the following conditions: During the warranty period Danfoss shall offer a new comparable product or repair the product if the product is found to be faulty by reason of defective design, materials or workmanship. The repair or replacement.
The decision to either repair or replace will be solely at the discretion of Danfoss. Danfoss shall not be liable for any consequential or incidental damages including, but not limited to, damages to property or extra utility expenses. No extension of the warranty period following repairs undertaken is granted. The warranty shall be valid only if the WARRANTY CERTIFICATE is completed correctly and in accordance with the instructions, the fault is submitted to the installer or the seller without undue delay and proof of purchase is provided. Please note that the WARRANTY CERTIFICATE must be filled in, stamped and signed by the authorized installer performing the installation (Installation date must be indicated). After the installation is performed, store and keep the WARRANTY CERTIFICATE and purchase documents (invoice, receipt or similar) during the whole warranty period. DEVIwarranty shall not cover any damage caused by incorrect conditions of use, incorrect installation or if installation has been carried out by non-authorized electricians. All work will be invoiced in full if Danfoss is required to inspect or repair faults that have arisen as a result of any of the above.
The DEVIwarranty shall not extend to products which have not been paid in full. Danfoss will, at all times, provide a rapid and effective response to all complaints and inquiries from our customers.
The warranty explicitly excludes all claims exceeding the above conditions. For full warranty text visit www.devi.com.
devi.danfoss.com/en/warranty/
Thermostat Floor Sensor ELKO
220-240V~
50-60Hz~
+5 to +45°C
15A/3450@230V~
Download manual:
Danfoss Devireg 530 Electronic Thermostat Installation Guide
Other manuals:
Danfoss Devireg 530 Electronic Thermostat Quick Guide
Danfoss Devireg 530 Electronic Thermostat Installation Guide
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…