For a large print version of these instructions please call Marketing on 0845 121 7400.
Hearby, Danfoss A/S declares that the radio equipment type CET2000B-RF + RX1-S is in compliance with directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address, http://heating.danfoss.co.uk/xdoccat/14_CATC-J_MNU17497125_SIT313.html
Danfoss can accept no responsibility for possible errors in catalogs, brochures, and other printed material. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
CET2000B-RF | RX1-S | |
Operating Voltage | 2.5 – 3 VDC (2xAA alkaline batteries) | 230Vac 50Hz |
Output Relay | – | 1 x SPDT Type 1B |
Switch rating | – | 3A (1) at 230Vac |
Output | – | Volt free |
Setting temp. range | 40-65°C | – |
Maximum ambient temp. | 0-45°C | |
Battery lifetime | 2 years | – |
Max. range | 30 metres | |
Operating frequency | 433.92MHz <1mW ERP | |
IP Rating | IP20 | IP40 |
Control | On-Off | |
Operating mode | Domestic Hot Water Heating | |
Construction | EN 60730-2-9 | EN 60730-1 |
Control pollution situation | Degree 2 | |
Rated impulse voltage | – | 2.5kV |
Ball pressure test | 75°C | |
Dimensions | H84 x W84 x D35 | H84 x W84 x D28 |
Software classification | A |
Important note RF products: Ensure that there are no large metal objects, such as boiler cases or other large appliances, in line of sight between the transmitter and receiver as these will prevent communication between thermostat and receiver.
This product should only be installed by a qualified electrician or competent heating installer, and must be in accordance with local wiring regulations.
Cable specification: minimum cross section 0.5mm2
Please Note: This product should only be installed by a qualified electrician or competent heating installer, and must be in accordance with local wiring regulations.
Mounting – CET2000B-RF
Slide the DIL switches to the settings required
To avoid unwanted tampering of the required hot water temperature the CET2000B-RF includes a key lock feature which disables the Λ and V buttons. First set the required hot water temperature using the Λ or V button. Then slide internal DIL switch 4 to the locked position and mount the CET2000B-RF back on its wallplate (as shown on page 9).
If the thermostat CET2000B-RF and receiver RX1-S have been supplied together in a combined pack, the units have been paired in the factory and no commissioning is required. If the thermostat and receiver have been supplied separately follow the steps below to pair the devices.
Danfoss Ltd Ampthill Road Bedford MK42 9ER
Tel: 01234 364621
Fax: 01234 219705
Email: ukheating@danfoss.com
Website: www.heating.danfoss.co.uk
Download Manual
Danfoss CET2000B-RF Wireless Cylinder Thermostat Installation Guide
OTHER MANUALS
Danfoss CET2000B-RF Wireless Cylinder Thermostat User Guide
Danfoss CET2000B-RF Wireless Cylinder Thermostat Data Sheet
Danfoss CET2000B-RF Wireless Cylinder Thermostat Installation Guide
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…