Cn-hysen

Cn-hysen HY607 WIFI Digital Thermostat User Manual

Cn-hysen HY607 WIFI Digital Thermostat

Many thanks for your selection of our products and services, and also for your trust and support to us

Features

Appearance

  • The standard total Size is 86*86mm
  • Touch buttons to make simple operation
  • The visible thickness above the wall is only 15mm86mm
  • hidden box and 60mm European box
  • Display size: 64*64mm
  • Color: white

Functions

  • Including built-in sensor and external sensor
  • 0.5°C accuracy keeps the temperature within the level you set.
  • Children lock to prevent misoperation by children
  • Data memory when power is off.
  • Holiday mode make you enjoy a more comfortable temperature in holiday
  • The temperature of the external sensor can be checked

Product Specifications

  • Power: 90-240Vac 50/60HZ
  • Display accuracy:0.5°C
  • Probe sensor:NTC(10k)1%
  • Contact capacity:3A/250V(WW);16A/250V(WE
  • Working environment temperature:0~90°C
  • Range of temperature adjustment:5~35°C
  • Range of temperature display:0~40°C
  • Insulating condition: Normal environment
  • Running program: Set per 1 week as a cycle
  • Output: Switch relay
  • Installation: Wall mounted or on battery seat
  • Size(mm):86*86*27

Before wiring and installing

  • Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition.
  • Check the ratings given in the instructions and on the product to make sure the produce is suitable for your application.
  • Installer must be a trained experienced service technician.
  • After installation is complete.check out produce operation as provided in these instructions

Wiring Diagram

Displays

Description of icon

  • Auto mode;run preset program
  • Temporary manual mode
  • Manual mode
  • Clock
  • Holiday mode, Holiday days and temperature can be set to run in countdown mode
  • Heating,,icon disappears to stop heating
  • EXT: External NTC sensor
  • WIFI connection, flashing EZ distribution mode
  • Cloud icon: flashing AP distribution network mode
  • Child lock
  • Open window

Operation key

NO symbols represent
A Turn ON/OFF:Short press to turn on/ turn off
B 1  Short press to switch automatic mode and manual mode

2   Turn  on  thermostat, long press  for 3-5 seconds to enter into programmable setting

3. Turn off thermostat, long press for 3-5 seconds to enter into the advanced A setting

C 1  Confirm key: use it withkey

2  Only short press it to set time

3 Turn on thermostat,long press it for 3-5 seconds to holiday mode setting. Appear

OFF, press  change to ON,then press  to confirm opening holiday mode 4 Turn off thermostat ,long press  to enter into advanced B setting

B 1  Decrease key

2  Long press to lock /unlock

D 1  Increase key :

2  Long press to inquire external sensor temperature

3  In the Auto model, pressenter to temporary manual mode

Programmable

5+2 (factory default),6+1, and 7 models 6 times period setting for user choose. In the advanced options choose the model you need, under power-on state, long press for 3-5 seconds enter into the programming mode setting, then short press choose: hour, minute, time period, press to adjust data, finish setting, about 10 seconds will automatically save and exist.

Advanced options A
Under turn off state, long press for 3-5 seconds to access the advanced A setting. From A1 to AE, short press to choose the option, and adjust data by, short press to switch next option. Remain about 5 seconds after finishing setting will quit setting

NO Setting Options Data Setting Function Factory Default
A1 Measure Temperature Calibration -9-+9℃ 0.5℃ Accuracy Calibration
A2 Temperature          control

return difference setting

0.5-2.5℃ 1℃
A3 Children lock setting 0:half lock 1:full lock 0

A4

Power function with memory 0:Power with memory function 1:Shutdown power after power off 2:Shutdown power after power on

0

A5

Backlight sleep brightness

0: 0% of brightness

1: 50% of brightness

2: 100% of brightness

1

A6 Weekly        programming selection 0: 5+2      1:6+1 2 :7 0
A7 Setting          temperature lowest limit 1-10℃ 5℃
A8 Setting          temperature

highest Limit

20-70℃ 35℃

A9

Protection temperature of low 1 :1-10℃

2:Exceed 10℃, screen display, Low temperature protection was cancelled.

5

AA

Protection temperature

of

high

1::35-70℃

2: low than 35 ℃ , screen display ,high temperature protection was canceled

45

AB Return different for high temperature protection 1-9 2

AC

Running temperature of open window function 1:10-20℃

2: low 10℃,screen display ,open window function was canceled

15

AD Running time of open window function 10-20 min 10
AE Reset Long press until whole display

Advanced options B
Under turn off state, long press for 3-5 seconds to access the advanced B setting

NO. Setting Options Data Setting Function Factory Default
BN Choose sensor N1: only inner sensor N2: only external sensor N3: both sensor N1
BC Descaling function 0: closed              1: open 0
BO version V1.0 1.0

Return difference: limit valve of the external sensor is 45℃ for factory default (A6), and the value of the external sensor control return difference (A3) is 2. when the temperature rise to 45℃, the relay stops working and will remind the high-temperature production alarm. If the temperature decline to 43℃relay continue to work and the heating alarm will be relieved. (it can be operated, only when the indoor temperature is lower than setting temperature )

Sensor fault display: please choose the correct working way of the built-in and external sensor, if choose wrongly or sensor fault (breakdown), “E1” or “E2” will be displayed on the screen. The thermostat will stop heating until the fault is eliminated

Warranty

We offer a warranty of 18 months, from the sales day. The products of our company can have a lifetime warranty,if it is not the quality problems, or beyond the warranty period, we will charge for the after-sale service.

reference:

download manuals:

Cn-hysen HY607 WIFI Digital Thermostat User Manual

Cn-hysen HY607 WIFI Digital Thermostat User Manual

wpx_thermostats

Recent Posts

Johnson Controls T7000e LCD Digital Thermostat Installation Guide

Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide

1 year ago

Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’S GUIDE

Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE

1 year ago

Hetta HS01RF WIRELESS THERMOSTAT KIT USER MANUAL

Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…

1 year ago

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat USER MANUAL

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…

1 year ago

Honeywell RLV450 PROGRAMMABLE THERMOSTAT USER GUIDE

Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…

1 year ago

Honeywell RLV431 Programmable Thermostat User Guide

Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…

1 year ago