IMPORTANT: Please read these instructions fully prior to use as they contain information that will help get the best from your wireless thermostat, ensuring it is operating correctly and safely. If during the installation or setup, you experience any issues please call 0344 292 7060 for assistance. Must be installed by a competent person. To ensure your safety make sure the mains power is switched OFF before accessing wiring. To prevent a short circuit from a loose wire:

  • Multi-core cables: Only remove enough outer insulation to allow secure fixing of the cores into the terminal block.
  • Single core cables: Secure them together with a cable tie as close as possible to the terminal block.

Contents

 

The Thermostat and Receiver Box within this pack are Pre-bound

Install the Receiver Box

 

Wiring

Install the Thermostat

The Thermostat and Receiver Box in this pack are pre-bound.

Parameters

 

No Description Settings
3OT Min. On Time 1- 5min
4LL Lower Limit 5 – 21 °C
5UL Upper Limit 21 – 35 °C
9LC Fail Safe 0 = Disabled

1 = Enabled

10BL Backlight 0 = Disabled

1 = Enabled

11CL Clock 0 = 24h

1 = 12h

12DS Daylight Saving 0 = Disabled

1 = Enabled

13TO Temp. Offset – 3 / + 3 °C
15SD Reset Schedule 0

1 = Reset

16FS Factory Reset 0

1 = Reset

17OP Optimum Start 0 = Disabled

1 = Optimum Start

18OS Optimum Stop 0 = Disabled

1 = Enabled

Table Stand and Wall Mount

 

Wireless Receiver Box
The Wireless Thermostat communicates wirelessly to the Receiver Box which is wired to the boiler. If the Thermostat loses wireless communication or becomes faulty, the boiler can be switched on or off manually using the button on the Receiver Box.

  • is displayed on the Thermostat when the wireless signal is good – The Receiver Box LED will be solid GREEN.
  • will flash on the Thermostat when the wireless signal is lost – The Receiver Box LED will flash RED.
  • If communication is lost move the Thermostat to another location to try and restore communication

To manually override the boiler using the Receiver Box:

  1. Press the button once to switch the boiler ON or OFF. The button LED should be:
    • Solid GREEN when the boiler is ON.
    • Off when the boiler is OFF.

Binding / Rebinding

The binding operation described below is required if:

  • Any of the system components (Wireless Thermostat or Receiver Box) are replaced.
  • The Receiver Box has incorrect or no binding data stored (e.g. when pre-bound system pack components have been mismatched).

NOTE: During the binding procedure keep approximately 1m distance between the Wireless Thermostat and the Receiver Box.

  1. Press and hold the Receiver Box push button for 15 seconds to reset any previously stored data.
    After 15 seconds the red LED will change to flashing 0.1sec on/0.9sec off.
    NOTE: After 5 seconds the red LED will start to flash 0.5sec on/0.5sec off, but continue to hold the button).
  2. Release the push button.
  3. Press and hold the Receiver Box push button for 5 seconds to enter the binding mode.
    The Red LED will start flashing at 0.5sec on/0.5sec off to confirm the binding mode has been entered.
  4. On the Wireless Thermostat press and hold MENU for 3 seconds to enter the binding screen
    with parameter 14A flashing
    If 1 is shown then it is already bound to a Receiver Box. If 0 is shown then there are no Receiver Box bounded
  5. To bind to a new Receiver Box, Press to enter the binding sub-menu.
  6. Press or to scroll to 1 and press again. After a few seconds, the binding result will be displayed
    on the screen with 1 representing successful bind, and 0 representing failure. If successful the red LED on the Receiver Box is switched off to confirm the successful binding operation.
  • Manufactured for and on behalf of Wolseley UK Limited,
  • 2 Kingmaker Court, Warwick Technology Park,
  • Gallows Hill, Warwick, Warwickshire,
  • United Kingdom, CV34 6DY
  • Hereby, Wolseley UK Limited declares that this product is in
  • compliance with Directive 2014/53/EU. The full text of the
  • EU declaration of conformity is available at the following
  • internet address: http://www.wolseley.co.uk
  • Receiver Category 2
  • Max RF Power: 25mW
  • 868-868.6MHz

Reference

Download Manual

Center EHE0200322 RF Wireless 7 Day Programmable Thermostat Installation Guide

OTHER MANUAL

Center EHE0200322 RF Wireless 7 Day Programmable Thermostat User Guide

Center EHE0200322 RF Wireless 7-Day Programmable Thermostat Installation Guide

wpx_thermostats

Recent Posts

Johnson Controls T7000e LCD Digital Thermostat Installation Guide

Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide

1 year ago

Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’S GUIDE

Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE

1 year ago

Hetta HS01RF WIRELESS THERMOSTAT KIT USER MANUAL

Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…

1 year ago

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat USER MANUAL

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…

1 year ago

Honeywell RLV450 PROGRAMMABLE THERMOSTAT USER GUIDE

Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…

1 year ago

Honeywell RLV431 Programmable Thermostat User Guide

Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…

1 year ago