1. Programming Menu 2. Settings Menu 3. Alert 4. Room Temperature 5. Current time 6. Heat demand 7. Optimisation 8. Low battery | 9. Wireless signal 10. Keypad Locked 11. Temperature adjust 12. Right button 13. Middle button 14. Left button 15. Schedule period 16. Day |
Temperature Override Active: Displayed if the programmed temperature has been manually adjusted. | |
Low Battery: Power has reached approximately 10% (see Changing the Batteries on page 9). | |
Heat Demand: Room temperature is below setpoint – indicating there is a demand for heating (boiler activity might occur). | |
Optimization Active: Only displayed if optimization has been enabled in the installer settings. | |
Wireless Signal: Thermostat (Wireless only) is connected to the Receiver Box. |
MENU Options and settings of your Thermostat:
Navigating the Menu
Heating Schedule
Your Thermostat comes with the following default schedule. Follow the next steps to adjust the heating schedule.
P1 | P2 | P3 | P4 | ||
Days 1 to 5 (Mon to Fri) | 6:30 | 8:00 | 18:00 | 22:30 | |
21°C | 16°C | 21°C | 16°C | ||
Days 6 to 7 (Sat to Sun) | 6:30 | 9:00 | 18:00 | 23:00 | |
21°C | 18°C | 21°C | 16°C |
Adjusting the Schedule
1. Press MENU | 2. Press |
3. Press | 4. Press |
5. Press | 6. Press |
7. Repeat these steps to make adjustments to the remaining periods and days – or press
Copy Schedule
1. Press | 2. Press |
1. Press MENU | 2. Press |
3. Press | 4. Press |
5. Press | 6. Press |
7. Press | 8. Press |
9. Press | 10. Press |
11. Press | 12. Press |
13. Press
Automatic Operation
During normal use, your Thermostat will follow the programmed schedule -indicated by the
Manual Operation
The set temperature is followed permanently – indicated by the
Temporary override
Press the
Permanent override
Press the
Save energy by switching the heating off when not required – e.g. during warmer summer months, or when doors and windows are open for extended periods of time. If the temperature drops to 5°C the heating will come on to prevent the heating pipes from freezing.
Press
Press
Optimization
Your Thermostat has optimization functions that aim to save energy while maintaining suitable comfort levels. The Thermostat displays
By default optimization is disabled, see instructions on the installation guide on how to activate it.
The Thermostat is powered by 2 x AA batteries, although a battery icon is not shown on the display during normal use.
The only time you will see the battery icon is when they become low on power.
If you have difficulty with your Thermostat, try these suggestions. Most problems can be corrected quickly and easily.
All models
Screen is blank | Replace the batteries. Contact installer. |
Thermostat shows | Batteries have less than 10% power and need to be replaced soon. |
Thermostat shows | Batteries are critically low and need to be replaced immediately -see ‘Changing the Batteries’. |
The thermostat shows | The boiler cycles on and off as it controls the temperature, and sometimes the If the boiler doesn’t switch on after a long period of time contact your installer. |
The heating system does not respond to temperature adjustments. | Make sure the set temperature is higher than the actual room temperature. Check the heating system is powered on. Check the Receiver Box is powered and that the Thermostat has a wireless signal (RF only). |
Thermostat shows | If the temperature sensor of your Thermostat is faulty, contact your installer to repair or replace the Thermostat. |
Wireless Thermostat & Receiver Box only
The thermostat is flashing | Wireless signal lost – Move the Thermostat to another location to try and restore communication. |
The thermostat is flashing | Check Receiver Box has power by pressing the button to switch the boiler on. If the Receiver Box has power then no wireless binding data is stored – Follow the binding procedure in the installation guide or contact your installer. |
The receiver Box | The receiver Box is in binding mode – will time out of this mode after 3 minutes. |
If during the installation or setup you experience any issues please call 0344 292 7060 for assistance.
Manufactured for and on behalf of Wolseley UK Limited,
2 Kingmaker Court, Warwick Technology Park,
Gallows Hill, Warwick, Warwickshire,
United Kingdom, CV34 6DY
For further information telephone 0344 292 7062
Whilst every care has been taken to ensure that the information included in this document was accurate at the time of printing, we reserve the right to change specifications at any time.
The photographs reproduced in this publication are within the constraints of the printing process and are NOT to be used for matching purposes. E&OE.
UG-340017_340018.v01
CE Importer
Wolseley UK Limited, Unit1, M2 Business Park, 132 Duncrue Street, Belfast, BT3 9ARWEEE Directive 2012/19/EU
At the end of the product, life disposes of the packaging and product in a corresponding recycling center.
Do not dispose of the unit with the usual domestic refuse.
Do not burn the product.
DOWNLOAD MANUALS:
CENTER 340022 7-Day Programmable Thermostats User Guide
OTHER MANUALS:
Center 340022 Programmable Thermostat Quick Start Guide
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…