Caution:
Turn off DRT 2 and the electrical devices, (e.g. heater, cooler), which will be connected before installation. It is highly recommended that the installation procedure is processed by trained personnel.
The thermostat should be mounted on an inner wall 1.5m above the floor in a position where it is readily affected by changes in the general room temperature with freely circulating air.
Avoid direct exposure to sunlight, dripping or splashing.
The location should be away from any direct heat/cool generating source.
Do not place the thermostat at a location where the air circulation is low or where it will be subjected to excessive temperature changes, (e.g. near a door).
Using the accessory screws and wall anchors provided mount the DRT 2 with the key-hole at the back. The thermostat should be mounted as shown in step 3. Replace the cover as shown in step 4.
Caution:
Turn off the electrical devices and disconnect the supply to the appliances before replacing the batteries.
Replace only with the same or equivalent type of batteries.
Do not dispose of batteries with household waste. Refer to local requirements for the correct disposal procedure.
Normal Time Setting Mode:
The heater / cooler turns on according to the activated program and the control temperature setting. When the heater / cooler is ON, the Program Number and the
The pre-defined programmes are shown below:
HEATER MODE | ON | OFF | TEMP | ON | OFF | TEMP |
MONDAY | 06.00 | 08.00 | 21°C | 18.00 | 22.00 | 16°C |
TUESDAY | 06.00 | 08.00 | 21°C | 18.00 | 22.00 | 16°C |
WEDNESDAY | 06.00 | 08.00 | 21°C | 18.00 | 22.00 | 16°C |
THURSDAY | 06.00 | 08.00 | 21°C | 18.00 | 22.00 | 16°C |
FRIDAY | 06.00 | 08.00 | 21°C | 18.00 | 22.00 | 16°C |
SATURDAY | 08.00 | 10.00 | 21°C | 18.00 | 23.00 | 16°C |
SUNDAY | 08.00 | 10.00 | 21°C | 18.00 | 23.00 | 16°C |
COOLER MODE | ON | OFF | TEMP | ON | OFF | TEMP |
MONDAY | 06.00 | 08.00 | 24°C | 18.00 | 22.00 | 26°C |
TUESDAY | 06.00 | 08.00 | 24°C | 18.00 | 22.00 | 26°C |
WEDNESDAY | 06.00 | 08.00 | 24°C | 18.00 | 22.00 | 26°C |
THURSDAY | 06.00 | 08.00 | 24°C | 18.00 | 22.00 | 26°C |
FRIDAY | 06.00 | 08.00 | 24°C | 18.00 | 22.00 | 26°C |
SATURDAY | 08.00 | 10.00 | 24°C | 18.00 | 23.00 | 26°C |
SUNDAY | 08.00 | 10.00 | 24°C | 18.00 | 23.00 | 26°C |
Press “PRG”, the hour will flash, press
Temporary / Permanent Override Mode:
There are 2 modes in the Override Mode, (Temporary Override Mode and Permanent Override Mode).
Press “
Normal Mode
Selecting the Temporary / Permanent Override Mode:
Review and adjust the Override temperature:
Temporary Override Mode:
The Temporary Override Mode maintains the temporary setting until the next program time is reached.
Permanent Override Mode:
The room temperature will be maintained at the Permanent Override temperature setting until the Permanent Override Mode is terminated.
Press “PRG” to release the Permanent Override Mode.
Sleep Mode:
In Sleep Mode the
Only the time is shown. The heater / cooler is turned off, irrespective of the current temperature setting.
Control Off Mode:
The LCD is fully turned off.
The heater / cooler is turned off, irrespective of the current control temperature setting.
Delay / No Delay jumper:
HEATER | COOLER | |
No Delay | 10 seconds | 4 minutes |
Delay | 4 minutes | 4 minutes |
Choose the “Delay” option if compressor heat is connected.
12 hours / 24 hours Mode jumper:
When the 12 hours option is selected the time is shown in 12 hour Mode. Otherwise the time is displayed in 24 hour Mode.
Heater / Cooler jumper:
Select the “Heater” option when a heater is connected to the thermostat. Select the “Cooler” option when a cooler is connected to the DRT 2.
TERMINAL BLOCK CONNECTING LABEL
1 Croftbank Crescent Uddingston Glasgow G71 7JD
Tel: 01698 327997
Fax: 01698 327776
Web: www.thermsaver.co.uk
Email: info@thermsaver.co.uk
DOWNLOAD MANUALS:
CELECT DRT2 Digital ProgrammableThermostat Instruction Manual
CELECT DRT2 Digital ProgrammableThermostat Instruction Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…