Warning:
Caution: Turn off DRF3 and the electrical devices (e.g. heater, cooler) which will be connected before installation. It is highly recommended that the installation procedure is processed by trained personnel.
The thermostat (Receiver and Transmitter) should be mounted on an inner wall 1.5m above the floor in position where it is readily affected by changes of the general room temperature with freely circulating air.
Prevent direct exposure to sunlight; dripping or splashing area. Do not place this unit at a location where air circulation is low, or where it has great temperature changes (e.g. near door). Do not place the thermostat near heat/cool generating sources.
Caution: Turn off the electrical devices and receiver before wiring.
There is 4-wire cable provided
Color | Connection |
Brown | 240Vac Live |
Blue | 240Vac Neutral |
Black | 240Vac Live |
Grey | Device’s power input |
It is recommended that a 10A fuse is fitted at grey wire.
(Please refer to the wiring diagram on the last page.)
Using the accessory screws and wall anchors provided, mount DRF3 with the key-hole at the back. The transmitter and receiver should be mounted on the wall and install the covers on them.
Install or replace the battery for transmitter:
Caution: Turn off the electrical devices and disconnect the supply to the appliances before replacing the batteries. Replace only with the same or equivalent type of batteries. Do not dispose the used batteries with
household waste. Refer to your local area for the proper disposal.
Start/Reset:
Normal Time Mode:
Temperature Setting Up:
Delay / No Delay jumper:
Heater Cooler
No delay 10sec 4mins
Delay 4mins 4mins
Choose the Delay option if compressor heat is connected.
Heater/Cooler jumper:
Select the heater option when a heater is connected to the receiver. Select the cooler option when a cooler is connected to the receiver.
Address setting:
In transmitter and receiver, there are dip switches to select the addresses. The receiver ignores the message which is sent by the transmitter with a different address.
DOWNLOAD MANUALS:
CELECT DRF3 Wireless Programmable Thermostat Instruction Manual
CELECT DRF3 Wireless Programmable Thermostat Instruction Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…