The thermostat with display can be used to manage the temperature control system (heating o cooling) of the rooms where it is installed, and can be configured for different applications based on needs.

Which system do you have?

MyHOME temperature system with central unit (par. 3.1) Master Probe
Thanks to the internal sensor, the thermostat can operate as master probe of a MyHOME system. In this case, it will obtain the set-points from the central unit that manages the system.

Hotel room system (par. 3.2) Hotel thermostat
The operation in the hotel room configuration gives the customer the possibility of easily setting the temperature to the desired level of comfort. The hotel manager can integrate the individual thermostat installed in the room as part of a system that can be managed using a software for the monitoring of consumptions, therefore avoiding unwanted energy waste.

Individual residential system (par. 3.3) Home Thermostat
The third type of use, as room thermostat, manages the temperature control of an individual system, without the need for additional control devices

Description

Meaning of icons and keys

  • Heating function.
  • Cooling function.
  • Operating mode icons (see table in paragraph 2.2).
  • MODE key: a short pressure changes the mode of operation of the device; an extended pressure (unless used as MyHOME probe) changes the function an extended pressure (unless used as MyHOME probe) changes the heating/cooling function. (This function can be disabled using the MyHOME_Suite software for the hotel thermostat and residential thermostat modes).
  • “+” key: increase the set value.
  • “–” key: decrease the set value.
  • FAN key: set the fan coil speed on 3 levels + automatic. (This function can be disabled using  the MyHOME_Suite software).
  • Heating/cooling on indicator (see table in paragraph 2.2).
  • Fan coil speed indicator, 3 levels.
  • Fan coil in automatic mode indicator.
  • Window indicator: active local contact according to the programming completed by the installer.
  • Measured (thermometer symbol on) / set (thermometer symbol off) temperature indicator.
  • Unit of measure: °C or °F measurement unit can be modified from the user menu.

Summary of functions and operating modes

Using the thermostat

Master Sensor in MyHOME temperature-control system (with control unit)
If configured to operate only as probe part of a MyHOME temperature system, the thermostat receives the main set-points from the central unit (temperature set-point, summer/winter set-point, etc.). You can change from normal operation to Comfort, ECO or Antifreeze/Heat protection mode using the local key. With MyHOME_Suite you can disable the change mode by local key. The setting of a manual temperature set-point is possible, but it is only temporary, as it will only last until the next set-point change sent by the central unit

Operating mode

  • Press the MODE key once or more, to select the desired mode
  • The symbol of the new mode appears and the set temperature flashes (thermometer symbol off). Use + and – to change the set-point.).
  • After a few seconds the new set-point is saved, and the measured temperature appears (thermometer symbol on).

Temporary manual mode

  • The set-point set by the central unit can be modified temporarily for the zone controlled by the thermostat. The manual set-point remains active until the central unit sends a new set-point.
  • Set the desired temperature using + or -; the display will show the symbol
  • After a few seconds the new set-point is saved and the measured temperature appears. In this example the set temperature is higher than the measured temperature, therefore also the heating on indicator will come on

Thermostat with display

Comfort, eco, antifreeze/thermal protection operating modes
Select one of these modes using the MODE key. The thermostat will no longer follow the settings of the central unit. The sensor mode must be set to automatic to be able to return to the control unit settings. The mode cannot be changed from the control unit or other control device. MyHOME_Suite can disable the mode key

Fan-coil adjustment

If the thermostat manages a fan-coil type load, it is possible to adjust the fan speed using the dedicated pushbutton. With MyHome suite you can disable the automatic speed setting by local key

Press FAN to set the fan speed at the desired level

Hotel Thermostat

This paragraph describes the use of the thermostat in a hotel room.

Temperature adjustment

  • Use + and – to change the current temperature setpoint.
  • Once the desired value has been set, wait a few seconds to save the new set-point
  • The temperature measured will appear.

Antifreeze or Thermal Protection

  • To switch from normal operation to Antifreeze (or thermal protection) press the MODE key.
  • The display shows the symbol and the value set:
    • 7 °C if heating is on;
    • 35 °C if cooling is on.
  • After a few seconds the new set-point is saved and the measured temperature appears.
  • To return to normal operation press MODE again.

Switching from heating / cooling function

  • To change from the heating function to the cooling function and viceversa keep the MODE key pressed for at least 7 seconds.
  • The change of function is indicated by the corresponding icon appearing on the display.
  • This operation may have been disabled during installation

Fan-coil adjustment
If the thermostat manages a fan-coil type load, it is possible to adjust the fan speed using the dedicated pushbutton. With MyHome suite you can disable the automatic speed setting by local key.

Press FAN to set the fan speed at the desired level.

Home Thermostat

The thermostat can be used in the residential sector for the management of a single system.

Temperature adjustment

  • Use + or – to adjust the current temperature setpoint.
  • Once the desired value has been set, wait a few seconds for the new set-point to be saved.
  • The value of the measured temperature will then appear.

Operating modes

  • Press the MODE key once or more to select the mode required
  • The symbol of the new mode appears and the set temperature flashes (thermometer symbol off). Use + and – to change the set-point.
  • After a few seconds, the new set-point is saved and the measured temperature appears (thermometer symbol on

Switching from heating/cooling function

  • To change from the heating function to the cooling function and viceversa keep the MODE key pressed for at least 7 seconds.
  • The display shows the set-point set for the heating or cooling function.
  • The change of function is indicated by the corresponding icon appearing on the display

Fan-coil adjustment
If the thermostat manages a fan-coil type load, it is possible to adjust the fan speed using the dedicated pushbutton.

Press FAN to set the fan speed at the desired level

Brightness adjustment

  • The display brightness can be adjusted on 10 levels.
  • Press the FAN key for at least 7 seconds.
  • The current brightness level appears on the display.
  • Use the + and – keys to increase or decrease the brightness.
  • Press the FAN key twice to confirm and quit the function.

Setting the temperature measurement unit

  • You can select setting the device on the temperature scale expressed in degrees °C or °F.
  • Press the FAN key for at least 7 seconds.
  • Press the FAN key again.
  • The current measurement unit appears on the display.
  • Use the + and – keys to change from one measurement unit to the other.
  • Press the FAN key to confirm and quit the function

Maintenance

In case of error

  • The “Er” symbol followed by a number on the display indicates an error condition of the thermostat.
  • In this case refer to the installer manual, or contact a trusted technician.
  • Below is an example of an error screen.

Some of the functions described in this manual and which can be configured by the MyHomeSuite software are available with the new Thermostat version, from week 20W16; the details are below:

  • colour icons;
  • local contact status icon;
  • the fan-coil ventilation can be set to always active;
  • fan-coil icon flashing during speed adjustment;
  • display backlighting adjustment;
  • Setting the temperature measurement unit by local keys.

BTicino

Reference

Download Manual:

bticino H4691 Myhome thermostat User Manual

OTHER MANUALS:

bticino Myhome H4691 thermostat Software Manual

bticino Myhome H4691 thermostat Installational Manual

bticino, H4691 Myhome thermostat User Manual

wpx_thermostats

Recent Posts

Johnson Controls T7000e LCD Digital Thermostat Installation Guide

Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide

1 year ago

Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’S GUIDE

Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE

1 year ago

Hetta HS01RF WIRELESS THERMOSTAT KIT USER MANUAL

Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…

1 year ago

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat USER MANUAL

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…

1 year ago

Honeywell RLV450 PROGRAMMABLE THERMOSTAT USER GUIDE

Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…

1 year ago

Honeywell RLV431 Programmable Thermostat User Guide

Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…

1 year ago