Attention To prevent damage to the thermostat, never use a sharp instrument to press the touchscreen keys. Always press keys with your fingers.
Warning For installation by experienced service technicians only.
Caution
This thermostat requires 24 Volt AC Power or 2 properly installed “AA” Alkaline batteries for proper operation. When connecting 24 Volt AC Power the batteries may be installed as a backup.
For use only as described in this manual. Any other use will void warranty.
This thermostat is compatible with:
Electrical and control specifications:
Terminations
Warning Disconnect power before beginning installation.
Thermostat Location
Install the thermostat approximately 5 feet (1.5m) above the floor in an area that has a good amount of air circulation and maintains an average room temperature.
Avoid installation in locations where the thermostat can be affected by drafts, dead air spots, hot or cold air ducts, sunlight, appliances, concealed pipes, chimneys and outside walls.
Install your new Braeburn thermostat in 4 basic steps:
Wiring Terminations for model 5310
Terminal | Function | Description |
G | Output | Fan Control |
Rc | Input | 24 Volt AC Cooling Transformer (Dual Transformer Systems Only) |
Rh | Input | Power Connection (24 Volt AC Heating Transformer or Millivolt Power Source) |
W1 | Output | Conventional Heat Relay |
O / B | Output | Reversing Valve (Cool Active or Heat Active) |
Y1 | Output | Compressor Relay |
C | Input | 24 Volt AC Transformer Common |
S1 | Input | Optional Remote Sensor (indoor or outdoor) |
S2 |
Wiring Terminations for model 5320
Terminal | Function | Description |
A | Output | Economizer Control |
G | Output | Fan Control |
Rc | Input | 24 Volt AC Cooling Transformer (Dual Transformer Systems Only) |
Rh | Input | Power Connection (24 Volt AC Heating Transformer or Millivolt Power Source) |
W1 / E / AUX1 | Output | (W1) 1st Stage Conventional Heat, (E) Emergency Heat, (AUX1) 1st Stage Auxiliary Heat |
W2 / AUX2 | Output | (W2) 2nd Stage Conventional Heat, (AUX2) 2nd Stage Aux Heat |
W3 / O / B | Output | (W3) 3rd Stage Conventional Heat, (O) Cool Active Reversing Valve (B) Heat Active Reversing Valve |
Y1 | Output | 1st Stage Compressor |
Y2 | Output | 2nd Stage Compressor |
C | Input | 24 Volt AC Transformer Common |
L | Input | System Malfunction Indicator |
S1 | Input | Optional Remote Sensor (indoor or outdoor) |
S2 |
Typical Wiring Configurations
NOTE: The “System Type” option will be configured in the Installer Settings section. The 5310 is a single stage thermostat and not intended for multi stage equipment.
Heat Only or Millivolt
Set System Type to 11CONV
Rh | Power Connection |
W1 | Heat Relay |
G | Fan Relay [note 4] |
C | 24 Volt AC Transformer Common [note 1] |
1 HEAT / 1 COOL Single or Dual Transformer
Set System Type to 11CONV
Rh | 24 Volt AC Power (heating transformer) [note 2] |
Rc | 24 Volt AC Power (cooling transformer) [note 2] |
W1 | Heat Relay |
Y1 | Compressor Relay |
G | Fan Relay |
C | 24 Volt AC Transformer Common [note 1, 3] |
2 HEAT / 2 COOL Single or Dual transformer
Set System Type to 22CONV
Rh | 24 Volt AC Power (heating transformer) [note 2] |
Rc | 24 Volt AC Power (cooling transformer) [note 2] |
W1 | Heat Relay Stage 1 |
W2 | Heat Relay Stage 2 |
Y1 | Compressor Relay Stage 1 |
Y2 | Compressor Relay Stage 2 [note 4] |
G | Fan Relay |
C | 24 Volt AC Transformer Common [note 1, 3] |
3 HEAT / 2 COOL Single or Dual Transformer
Set System Type to 32CONV
Rh | 24 Volt AC Power (heating transformer) [note 2] |
Rc | 24 Volt AC Power (cooling transformer) [note 2] |
W1 | Heat Relay Stage 1 |
W2 | Heat Relay Stage 2 |
W3 | Heat Relay Stage 3 |
Y1 | Compressor Relay Stage 1 |
Y2 | Compressor Relay Stage 2 [note 4] |
G | Fan Relay |
C | 24 Volt AC Transformer Common [note 1, 3] |
NOTES – Conventional Systems
NOTE: Additional options are configured in the Installer Settings section.
S1 | Indoor or Outdoor Remote Sensor [note 1] |
S2 | |
A | Economizer Control (5320 only) [note 2] |
NOTES – Additional Wiring Options
NOTE: The “System Type” option will be configured in the Installer Settings section. The 5310 is a single stage thermostat and not intended for multi stage equipment.
1 HEAT / 1 COOL – No Auxiliary Heat
Set System Type to 11HP
Rh | 24 Volt AC Power |
Rc | Connected to Rh with supplied Jumper Wire |
O/B | Changeover Valve [note 2] |
Y1 | Compressor Relay (appears as Y on the 5310) |
G | Fan Relay |
C | 24 Volt AC Transformer Common [note 1] |
2 HEAT / 2 COOL – No Auxiliary Heat
Set System Type to 32HP
Rh | 24 Volt AC Power |
Rc | Connected to Rh with supplied Jumper Wire |
O/B | Changeover Valve [note 2] |
Y1 | Compressor 1 Relay (1st stage heating/cooling) |
Y2 | Compressor 2 Relay (2nd stage heating/cooling) |
G | Fan Relay |
C | 24 Volt AC Transformer Common [note 1] |
L | Optional System Fault Monitor [note 4] |
2 HEAT / 1 COOL – Including Auxiliary Heat
Set System Type to 22HP
Rh | 24 Volt AC Power |
Rc | Connected to Rh with supplied Jumper Wire |
O/B | Changeover Valve [note 2] |
Y1 | Compressor Relay (1st stage heating/cooling) |
W2 | Auxiliary Heat Relay (2nd stage heating) [note 3] |
E | Emergency Heat Relay [note 3] |
G | Fan Relay |
C | 24 Volt AC Transformer Common [note 1] |
L | Optional System Fault Monitor [note 4] |
3 HEAT / 2 COOL – Including Auxiliary Heat
Set System Type to 32HP
Rh | 24 Volt AC Power |
Rc | Connected to Rh with supplied Jumper Wire |
O/B | Changeover Valve [note 2] |
Y1 | Compressor 1 Relay (1st stage heating/cooling) |
Y2 | Compressor 2 Relay (2nd stage heating/cooling) |
AUX1 | Auxiliary Heat Relay (3rd stage heating) [note 5] |
G | Fan Relay |
C | 24 Volt AC Transformer Common [note 1] |
L | Optional System Fault Monitor [note 4] |
4 HEAT / 2 COOL – Including Auxiliary Heat
Set System Type to 42HP
Rh | 24 Volt AC Power |
Rc | Connected to Rh with supplied Jumper Wire |
O/B | Changeover Valve [note 2] |
Y1 | Compressor 1 Relay (1st stage heating/cooling) |
Y2 | Compressor 2 Relay (2nd stage heating/cooling) |
AUX1 | Auxiliary Heat Relay 1 (3rd stage heating) [note 5] |
AUX2 | Auxiliary Heat Relay 2 Relay (4th stage heating) |
G | Fan Relay |
C | 24 Volt AC Transformer Common [note 1] |
L | Optional System Fault Monitor [note 4] |
NOTES – Heat Pump Systems
NOTE: Additional options are configured in the Installer Settings section.
S1 | Indoor or Outdoor Remote Sensor [note 1] |
S2 | |
A | Economizer Control (5320 only) [note 2] |
NOTES – Additional Wiring Options
Attach Thermostat to Sub-Base
NOTE: This thermostat ships configured as a 1H/1C conventional thermostat. Confirm installer settings. See page 10.
Thermostat Display
Thermostat TouchPadsTM
NOTE: Thermostat TouchPads are located on the left, right and bottom portions of the display screen. They are the “touch sensitive” segments used to adjust your thermostat. Depending on the equipment installed, all touch pads may not show.
Outdoor Temperature
If a Braeburn® outdoor temperature sensor was connected, you may touch the room temperature area of the screen to view the outdoor temperature.
The Installer Settings must be properly configured in order for this thermostat to operate correctly. The Installer Settings are menu driven. The portion of these settings that do not apply to your setup will be skipped. These settings are indicated below with comments. More detail on each setting follows this table.
No. | Installer Setting (Notes follow this table) | Factory Default | Setting Options | Comments (More information follows this table) |
1 | Residential or or Commercial Profile | RES | RES COMM | Select for Residential profile Select for Commercial profile |
2 | Programming Mode [note 1] | 7 PROG | 7 PROG 52 PROG NO PROG | Select for 7 day programming mode Select for 5-2 day programming mode Select for non-programmable mode |
3 | Clock Format | 12 HR | 12 HR 24 HR | Select for 12 hour clock Select for 24 hour clock |
4 | Temperature Scale | F DEG | F DEG C DEG | Select for Fahrenheit display Select for Celsius display |
5 | Auto Changeover | oF AUTO | oF AUTO ON AUTO | Disables Auto Changeover mode Enables Auto Changeover mode |
6 |
System Type |
11CONV | 11CONV | Select for 1H/1C Conventional system |
22CONV 32CONV | Select for 2H/2C Conventional system Select for 3H/2C Conventional system | |||
11HP | Select for 1H/1C Heat Pump system | |||
22HP 32HP 42HP | Select for 2H/2C Heat Pump system Select for 3H/2C Heat Pump system Select for 4H/2C Heat Pump system | |||
7 | 1st Stage Differential | 0.5 DIF1 | 0.5, 1.0 or 2.0 DIF1 | Select a 1st stage temperature differential of .5°, 1° or 2° F (.25°, .5° or 2° C) |
8 | 2nd Stage Differential [note 2] | 2.0 DIF2 | 1.0, 2.0, 3.0, 4.0, 5.0 or 6.0 DIF2 | Select a 2nd stage temperature differential of 1°, 2°, 3°, 4°, 5° or 6° F (.5°, 1°, 1.5°, 2°, 2.5° or 3° C) |
9 | 3rd Stage Differential [note 2] | 2.0 DIF3 | 1.0, 2.0, 3.0, 4.0, 5.0 or 6.0 DIF3 | Select a 3rd stage temperature differential of 1°, 2°, 3°, 4°, 5° or 6° F (.5°, 1°, 1.5°, 2°, 2.5° or 3°C) |
10 | 4th Stage Differential [note 2] | 2.0 DIF4 | 1.0, 2.0, 3.0, 4.0, 5.0 or 6.0 DIF4 | Select a 4th stage temperature differential of 1˚, 2°, 3°, 4°, 5° or 6° F (.5°, 1°, 1.5°, 2°, 2.5° or 3° C) |
No. | Installer Setting (Notes follow this table) | Factory Default | Setting Options | Comments (More information follows this table) |
11 | 1st Stage Fan Control [note 3] | HG FAN 1 | HG FAN 1 HE FAN 1 | Select for 1st stage Gas heating Select for 1st stage Electric heating |
12 | Emergency Heat] Fan Control [note 4] | HE EMER | HE EMER HG EMER | Select for Electric Emergency Heat Select for Gas Emergency Heat |
13 | Reversing Valve (O/B Terminal) [note 5] | REVO | REVO REVB | Select for cool active Reversing Valve (O terminal) Select for heat active Reversing Valve (B terminal) |
14 | Fossil Fuel Backup Heat [note 4] | AE AUX | AE AUX AG AUX | Select for Electric Auxiliary heat (with compressor) Select for Gas Auxiliary heat (without compressor) |
15 | Compressor Power Outage Protection [notes 4, 6] | oF CPOP | oF CPOP on CPOP | Disables Power Outage Lockout Delay Enables Power Outage Lockout Delay |
16 | AC Power Interrupt Warning [note 6] | AC oF MONR | AC oF MONR AC on MONR | Disables AC Power Interrupt Warning Enables AC Power Interrupt Warning |
17 | Compressor Short Cycle Protection | 5 CSCP | 5, 4, 3, 2 or 0 CSCP | Select a compressor short cycle protection delay of 5, 4, 3, 2 or 0 minutes |
18 | Residual Cooling Fan Delay | 60 FAN | 90, 60, 30 or 0 FAN | Select a Residual Cooling Fan Delay of 90, 60, 30 or 0 seconds. |
19 | Circulating Fan Lock | oF CIRC | oF CIRC on CIRC | Disables Circulating Fan Lock mode Enables Circulating Fan Lock mode |
20 | Adaptive Recovery Mode (ARM™) [note 7] | oF REC | oF REC on REC | Disables Adaptive (early) Recovery mode Enables Adaptive (early) Recovery mode |
21 | Indoor Remote Sensor Control* [note 8] | I SENS | I SENS E SENS A SENS | Temperature is sensed from thermostat only. Temperature is sensed from remote sensor only. Temperature is combined with the thermostat and the remote sensor. |
22 | Lockout Security Level | 2 LOCK | 2 LOCK | If locked – Complete lockout is enabled |
1 LOCK | If locked – Partial lockout is enabled (SpeedBar® is still functional) | |||
23 | Auto Changeover Dead Band [note 9] | 3 BAND | 2, 3, 4 or 5 BAND | Select a Dead Band of 2°, 3°, 4° or 5˚ F (1°, 2° or 3° C) for Auto Changeover mode. |
24 | Compressor Balance Point [notes 4, 10] | NO BALC | NO BALC | Disables Balance Points |
15-50 BALC | Select a Compressor Balance Point of 15°- 50°F (-9°-10° C) | |||
25 | Auxiliary Heat Balance Point [notes 4, 10] | NO BALA | NO BALA | Disables Balance Points |
70-40 BALA | Select a Auxiliary Heat Balance Point of 70°- 40° F (21°- 4° C) | |||
26 | Outside Air Intake (A Terminal) [note 11] | OR NONE | OR NONE OR ECON OR TOD | Disables Outside Air Intake option Enables Outside Air Intake (Economizer Mode) Enables Outside Air Intake (Time of Day Mode) |
27 | Heat Set Point Upper Limit | 90LIM | 90-60 LIM | Select a Heat Set Point Upper Limit of 90°-60° F (32°-10° C) |
28 | Cool Set Point Lower Limit | 45LIM | 45-80 LIM | Select a Cool Set Point Lower Limit of 45°-80° F (7°-27° C) |
When a Braeburn® outdoor sensor is connected, the thermostat automatically recognizes it. Press room temperature digits to
display outdoor temperature.
NOTE: Additional options such as Service Monitors, Setting the lock code, audible tone, etc. are located in the
User Settings – See User manual for information on setting these options
NOTES – Installer Settings
Detailed Explanation of Installer Settings (also see NOTES above):
Time Step / Override | Cooling Call | External Air Output (A) | ||
Economizer Mode | Time of Day Mode | Disabled | ||
Occupied | YES or NO | ON | ON | OFF |
Unoccupied | YES | ON | OFF | OFF |
NO | OFF | OFF | OFF | |
Override | YES or NO | ON | ON | OFF |
Time Step / Override | Heating Call | External Air Output (A) | ||
Economizer Mode | Time of Day Mode | Disabled | ||
Occupied | YES or NO | ON | ON | OFF |
Unoccupied | YES | OFF | OFF | OFF |
NO | OFF | OFF | OFF | |
Override | YES or NO | ON | ON | OFF |
Warning Read Before Testing
NOTE: The compressor delay can be bypassed by pressing the reset button on the front of the thermostat. All user settings will be returned to factory default, however all Installer settings will remain as originally programmed in section 4.
When installed by a professional contractor, this product is backed by a 5 year limited warranty. Limitations apply. For limitations, terms and conditions, you may obtain a full copy of this warranty:
Braeburn Systems LLC
2215 Cornell Avenue Montgomery, IL 60538
Technical Assistance: www.braeburnonline.com
Call us toll-free: 866-268-5599 (U.S.)
630-844-1968 (Outside the U.S.)
©2013 Braeburn Systems LLC • All Rights Reserved • Made in China.
Download Manual
Braeburn 5310 Programmable Touchscreen Thermostat Installation Guide
Braeburn 5310 Programmable Touchscreen Thermostat Installation Guide
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…