User Notes
Caution: Risk of electric shock or equipment damage
Note: WP for water heating; EP for electric heating; WPB for gas boiler
This product is installed with a standard 86 control switch (in compliance with European regulations)
Press
KEY | OPTION | ICON | TIME | ADJUST | DEFAULT | ADJUST | |
| workday | 1 | 06:00 | 20℃ | |||
2 | 08:00 | 15℃ | |||||
3 | 11:30 | 15℃ | |||||
4 | 12:30 | 15℃ | |||||
5 | 17:00 | 22℃ | |||||
6 | 22:00 | 15℃ | |||||
Holiday | 1 | 08:00 | 22℃ | ||||
2 | 23:00 | 15℃ |
When POWER OFF, press the
Press
1 | Temperature compensation | The default value of the calibration room temperature is -2 ℃. Press the up and down keys to adjust. The adjustable range is 9.9 °C to -9.9 ℃. |
2 | Sensor selection | The temperature sensor is selected as IN by default. Press the up and down keys to adjust as IN respectively, indicating that the internal. |
3 | Modify the temperature limit | The default temperature limit value is 35 ℃. Press the up and down keys to adjust the range from 5 ℃ to 60 ℃. |
4 | Temperature difference start | The default temperature difference is set to 1 ℃. Press the up and down keys to adjust the range to 1-10 degrees. |
5 | Antifreeze funding | Set the default anti-freeze function to OFF, display OFF, press the up key to tum on anti-freeze, and display ON |
6 | Holiday option and turn off weekly programming | Set the default rest day as double OFF. Press the up and down keys to adjust it to double OFF (1-5), single OFF (1-6), no OFF (1 -7), and tum off week programming (OFF). |
7 | Primary and secondary reverse selection | Set the default main and auxiliary reversal to 0. Press the up and down keys to adjust 0 to tum off the main and auxiliary reversal. 01 means auxiliary reverse, 02 means auxiliary reverse, 03 means main and auxiliary reverse, shutdown and antifreeze is not on, stop output |
8 | Passive linkage output delay time | Set the default passive linkage delay time to 0. Press the up and down keys to adjust the range of 0-5 minutes. |
9 | Set upper-temperature limit | The default value of the set temperature upper limit is 60 ℃, and the adjustment range is 35-95 ℃ by pressing the up and down keys. |
10 | Restore Factory Defaults | Set to restore the factory default setting to display “-”, Press the up button to adjust the display “—”, press the enter button to restore the factory settings |
Download Manual
BEOK TOL-48 Heating Thermostat User Guide
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…