TGT70 series thermostats are luxurious programmable thermostats with large screen displays. It is applied to temperature control of the industrial, commercial, and domestic room, and start of control heating appliance, especially used in the floor-heating systems.
Power Supply | 200 ~ 240V 50 ~60Hz |
Current Load | ≤3A(water heating) ≤16A(electric heating) |
Power Consumption | <0.3W |
External Material | PC+ABS (flame retardant) |
Sensing Element | NTC |
Set Temp. Range | 5-99℃ (factory setting 5-35℃) |
Floor Set Temp. Range | 5-99℃ |
Accuracy | ±1℃ |
Dimension | 86x86x13.3mm |
Ambient Temp. | 0-45℃,5-95%RH(Non-condensing) |
Storage Temp. | -5~55℃ |
Timing Error | <1% |
Main Functions and Characteristics
User Interface Explanation
Model | Current Loading | External Sensor | Week Programmable | Child Lock | Drop up |
TGT70-EP | 16A | ✓ | ✓ | ✓ | Optional |
1-GT70-WP | 3A | ✓ | ✓ | ✓ | Optional |
Period | Period Icon | Defaulted Time | Defaulted Temp. | |
Week | 1 | | 6:00 | 20℃ |
2 | 8:00 | 15℃ | ||
3 | 11:30 | 15℃ | ||
4 | 12:30 | 15℃ | ||
5 | 17:30 | 22℃ | ||
6 | 22:00 | 15℃ | ||
Weekend | 1 | | 8:00 | 22℃ |
2 | | 23:00 | 15℃ |
Remark:
During power-on, press and hold
In the state of power-off, long press and hold
Display Code Function | Setting And Options | Factory Default | |
SEN | Sensor mode | 0:Internal sensor 1:Floor sensor 2:Both internal sensor and floor sensor | 0 |
LIV | Set temp. the range for the floor sensor | 5-99°C | 42°C |
DIF | Precision floor temp. | 1-9°C 2°C | 2℃ |
SAVE | High limit temp. for internal sensor | 5-99°C 35°C | 35℃ |
SVL | Low limit temp for internal sensor | 5-99°C | 5°C |
ADJ | Measure temp. | Check and calibrate the actual room temp. | 0.5°Caccuracy calibrate |
FRE | Anti-frozen | 00 : Close anti-frozen 01 : Open anti-frozen | 00 |
PON | Power memory | 00: Power memory off 01 : Power memory on | 00 |
DFI | Precision for room temp. | 0.5-3°C | 1°C |
FAC | Factory setting | 00: Return to factory setting 08 : Just display | 08 |
Remark:
Deadzone for floor temp.: i.e. the setting deadzone for floor sensor is 2, OSV is 42℃ when actual temp. reach 44℃, the relay will stop working; when actual temp. is back to 40℃, the relay starts working again. It works when room temp. is lower than set temp.
Sensor error:
Please select the right sensor mode. If select a different mode or there is an error of the sensor, Err will display on the LCD screen, the thermostat will stop heating till the problem is solved.
This product is suitable for standard 80*80mm wall boxes and 60 mm European round box.
NOTICE: The installation wire should be 1.5-2.5mm2.
Thank you for buying this product!
Please read this manual for complete instructions on installing and operating your thermostat. If you require further assistance, please feel free to contact us.
In the box you will find:
Model | TGT70-EP | TGT70-WP |
Thermostat | √ | √ |
User Manual | √ | √ |
Screws | √ | √ |
Dryer | √ | √ |
External sensor | √ |
Our Service:
We offer a warranty of 24 months from the sales day.
During the warranty, if it belongs to the quality issue, we will fix or replace them for you by free after testing them.
If it is not a quality problem or beyond the warranty time, we will charge for the after-sales service.
Warning The symbol
DOWNLOAD MANUAL
BEOK TGT70 Glass Screen Thermostat Instruction Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…