Supply voltage | AC100~240V;50–60Hz | |
Power consumption | 1W Max (Wi-Fi 3W Max) | |
Temp. setting range | 5~95°C | |
Floor limited range | 20.90°C | |
On/off deviation | 0.5~10°C, Factory setting ± 1°C | |
Ambient temperature | -5,–50°C | |
Protection level | I P20 | |
Shell material | Anti-Flammable PC |
This series of thermostats has Floor Heating, Fan Coil, and Integrated version, meeting the requirements under different scenarios.
Version | System mode | Model | Application |
Floor heating | Heating | EP Weekly programming | Built-in & floor sensor, floor limit sensor + |
WP | An NC/NO dual-output + Weekly programming | ||
WP B | An NC/NO dual-output + Weekly programming+ Potential-free output | ||
Fan Coil | Heating /Cooling / Ventilation | Ac2 | Timer task + 2-pipe system |
Ac2 485 | Timer task + 2-pipe system + 485Modbus (optional) | ||
Ac4 | Timer task + 4-pipe system + 485Modbus (optional) | ||
Integrated | Heating / Cooling / Ventilation/Floor heating / Floor heating + Heating | AW y | Floor heating & fan coil, weekly programming + Potential-free output + Timer task + 485Modbus (optional) + Door card (optional) |
Auto-mode Setting
When device is off, press ”
Events | Time | Temperature | ||||
Default value | Modify | Default value | Modify | |||
Workdays | Sunrise | 0 6 | 0 0 | 20°C | ||
Morning | 0 8 : | 0 0 | 1 5 °C | |||
Nooning | 11 : | 30 | 15°C | |||
Afternoon | 12 : | 30 | 15°C | |||
Evening | 17 : | 00 | 22°C | |||
Night | 22 : | 00 | 15°C | |||
Weekends | Sunrise | 06 : | 00 | 20°C | ||
Night | 22 : | 00 | 15°C |
Advanced Setting (Usually for Professional Technicians)
Choose “advanced setting” on the menu page and put in password 123456 to enter the advanced setting page, set parameters then press “
Meaning | Default value | |
Sensor Mode | Built-in Sensor Floor Sensor Built-in Control&Floor Limitation | IN |
Buit4n Sensor Calibration | –5-5°C | —3°C |
Buit-in Max Setting Value | 5-95°C | 50°C |
Floor Max Setting Value | 10-95°C | 50°C |
Limitation Value | 20-95°C | 35°C |
Output Jitter Control | 0-5°C | 1*C |
Anti-Freeze Protection | ON/OFF | OFF |
Linkage Mode | Noninverting Inverting Inverting Inverting and Anti-Freeze closed | Noninverting |
Linkage Time Delay | 0-5Min | 0Min |
Weekday Mode | Monday to Friday/Monday to Saturday /Monday to Sunday/ | 2-d a y |
Boot Type | Function Off/Functon On/Function Saved | 0 F F |
Temperature Unit | F/QC | QC |
Child Lock Type | None Lock All All but power | None |
Control Mode | All/Air/Floor | Floor |
Cloud Region | CN/US/EU | CN |
Reset All Settings | / | / |
Sensor failure
Please select the work mode of sensors correctly. When it shows EO/E1 error, the thermostat will stay power-off till the error is eliminated.EO: the built-in sensor is short-circuited or disconnected. El: floor sensor is short-circuited or disconnected.
Timer Task Setting (Fan Coil/Integrated)
Press”
The thermostat adopts a pre-guide and limited snap-fit design. It is easy to mount.
Connecting Diagram
The thermostat operates in full capacity in areas with an altitude of less than 2500 above sea level. The power rating of external load should be less than or equal to 80% rated power of the thermostat in areas with an altitude of 2500m to 4200m.
Floor Heating
DOWNLOAD MANUAL
BEOK TCR7 WiFi RGB Colorful LCD Screen Smart Thermostat Instruction Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…