BOT series boiler thermostats are with LCD digital display big screen, and it is developed according to the market’s requirements. Thermostats can be installed on the wall, or directly put on the table. This series of thermostats are easy to operate and with complete functions. It can be used to control boilers, motorized ball valves, motorized valves, electric valves, solenoid valves, etc.

Technical Parameter

Working Voltage USB type C (SV)
Current Load 3A
Temperature Control Accuracy ±1°C
Setting Temperature Range 5-60°C
Limiting Temperature Range 5-99°C
Consumption <0.3W
Temperature Sensor NTC

Main Button Instruction

  • : ON/OFF Switch;
  • : Mode Button. Switch between Manual Mode , Auto Period Control Mode, Temporary Manual Mode. Long press to enter the period setting.
  • :Time Set. Hour, minute and week setting;
  • :Up Button. To increase temperature. When press it with and it can set the programmable function;
  • ; Down Button. To reduce temperature. When pressing it with and it can set programmable functions;
  • : Key Lock. Long press 5 seconds to lock or unlock;

User Interface Explanation

Model Spec

Model Wireless Function Terminal Receiver Wi-Fi Function
BOT-W306
BOT-X306 / /
BOT306RF-WIFI / / /

Operation Instruction

Time Setting

Press , the time area will display Minute, Hour and Week, then press  or to modify time.

Programmable Period Temperature Setting 

First step, long press , screen display LooP (Cycling Control), screen displays 12345 (From Monday to Friday); Press  one time, it displays 123456(From Monday to Saturday); Press  two times, it displays 1234567(From Monday to Sunday);

Second step, time and temperature setting in every period. When screen display 12345 or 123456 or 1234567,  press to enter temperature setting. Press to enter time setting. To modify and save through or .

Att: When auto-control  ,if user needs to reset the temperature, it can be changed to temporary manual control. Temporary manual control means when the thermostat is in auto-control mode(program mode), the user press or modifies the temperature setting, the thermostat now is in a temporary manual control state. When the next period comes, the thermostat will automatically return to acquiescent period program control mode.

Programmable Period Time Setting 

First press  , then  press to change to time options, user can modify time in the period.

Default Program Data

Att

  1. The default temperature values of 3 and 4 periods in a workday is the same as with 2 periods. If the user need, please change this default temperature.
  2. Setting the temperature is 00, means this period is powered off.

Advanced Setting

In the state of power-off, long press and hold  then press  into advanced setting mode. Then press  to set relative item.

Display Code Function Setting And Options Factory Default
dIF Limit temp. return difference 0.5-4.5℃ 2℃
SVH Set temp. upper Limit 5-99℃ 35℃
SVL Set temp. low limit 5-99℃ 5℃
AdJ Measure temp. -5-5℃(0.5℃accuracy correction) 0.0℃
FrE Anti-frozen 00:Close   anti-frozen01:Open   anti-frozen 00
LOC Button lock function 00: Unlock01: except power switch, all buttons are locked

02: All buttons are locked

00
SNP Set Sequence Number 00:Close this function 01:Open this function 0
FAC Factory setting 08:Just display00:Return to factory setting 08

Wiring Diagram


The button inside the receiver is a Reset button. When the status indicator light stays on or is not on, the user can press reset button to resume normal work.

Att

Installation wires should be changed to be 1.5-2.5mm² hard line. Please rightly connect the wires strictly according to the connection diagram. Don’t make water, mud and other debris into the thermostat, otherwise it will damage the thermostat.

WIFI Configure

Install the APP on the phone

For iOS system: Login in App Store, search “ Beok RF Boiler”, you can download it on your iphone.

For Android System: Login in Google Play, search “Beok RF Boiler ”, you can download it on your phone.

Connection Thermostat with Phone

Thermostat Setting 

  1. Download and Install APP on phone.
  2. Press the thermostat button for 10 seconds when the thermostat is in turn-off state, then WIFI signal will appear and quickly twinkle.
  3. Enter your wifi name and password, then start the connection configure.

APP Interface on the Phone 

Thermostat Setting through Phone Operation 

  1. Clock : You can press Time Matching switch to match your phone clock with thermostat clock.
  2. Children lock (screen locking) : Press to lock the thermostat.
  3. Anti-Freezing: Press thermostat will show on the screen , it means Anti-freezing function open.
  4. Temperature setting: You can drag the pointer on Temperature Setting Dial to set temperature. Or press and to set temperature step. directly
  5. Period setting: Long press Period Display , then you will go into the Period Setting mode
  6. Advanced Setting: Long Press Senior , you will go into Advanced setting mode:
  7. Switch of Manual mode and Auto mode: Press to switch manual mode or Auto mode.
  8. Power off : Press to turn on or off thermostat.

Installation Instruction


Insert the equipped USB (Type-C) connector into the charger.

Set Sequence Number

  1. Every thermostat has a matched receiver, and thermostat and receiver have a same group of sequence number. If user mix during installation, sequence number can be set through the following method.(Sequence number is unique)
  2. In Advance Setting, SNP need to be set 01. Then to set SN through the following four steps.

The first step, press button under power off state, then press button, then press button to enter parameter setting;

The second step, after appearing SN1, press or to modify the number;

The third step, every time pressing once , it will appear SN2, SN3, SN4, SN5 and SN6 in order. Refer to second step, press or to modify.

The forth step, after SN is finished setting, if CHK Code is the same with bar code, it is correct. If not consistent, it is not correct. Please input again. 3.VAC: Control valves1-8 place numbers. The default value is 01. (This setting is only useful when thermostat is applied to control Wireless Main-Control Centralized Controller. If thermostat is used to control boiler, this setting must be 01.)

ATT

Thank you for buying this product!
Please read this manual for complete instructions on installing and operating your thermostat. If you require further assistance, please feel free to contact us.

In the box you will find:

Model BOT-W306 BOT-X306 BOT306RF-WIFI
Thermostat
User Manual
Screws
Receiver
USB Cable
Support Bracket

Our Service: 

We offer the warranty of 24 months from the sales day.
During the warranty, if it is belong to the quality issue, we will fix or replace them for you by free after test them. If it is not quality problem or beyond the warranty time, we will charge for the after-sales service.

 Warning:

The symbol means the unit is being installed, it may cause electrical shock hazard during maintenance, so please make sure it is operated by a professional technical worker.

REFERENCE

Download Manual

BEOK BOT306RF-WiFi Boiler Thermostat User Guide

Beok BOT306RF-WIFI BOILER THERMOSTAT User Guide

wpx_thermostats

Recent Posts

Johnson Controls T7000e LCD Digital Thermostat Installation Guide

Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide

2 years ago

Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’S GUIDE

Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE

2 years ago

Hetta HS01RF WIRELESS THERMOSTAT KIT USER MANUAL

Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…

2 years ago

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat USER MANUAL

HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…

2 years ago

Honeywell RLV450 PROGRAMMABLE THERMOSTAT USER GUIDE

Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…

2 years ago

Honeywell RLV431 Programmable Thermostat User Guide

Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…

2 years ago