This set is suitable for wall-hung boiler temperature control. As long as you install the receiver RC9 device near the wall-hung oiler, even if the thermostat T9N/T9W is placed in the living room or room (with an open distance of 100 meters), the RC9 can be controlled by the T9N/TOW thermostat.
Power supply | 3 x 1.5 V alkaline AA batteries |
Temp. setting range | 5~95’C |
Ambient temperature | -5~50’C |
Measurement accuracy | 0.1•c |
Setting temp. accuracy | 0.5°C |
Transmission distance | .;2oom in the open air |
Protection level | IP20 |
Wireless frequency | 433MHz (FSK) / 433MHz (Bidirectional FSK) |
RF RECEIVER
Power supp | AC100~240V; 50/60Hz |
Devioe power consumption | 1W Max |
Ambient temperature | -5-50’C |
Transmission distanoe | ,;;200m in the open air |
Wireless frequency | 433MHz (FSK) / 433MHz (Bidirectional FSK) |
[ RF Thermostat l
[ RF Receiver l
Press ‘the knob key for 3 seconds to edit the auto-mode setting
Under power-off, press “M ” for 3 seconds to enter advanced setting mode, then repress “M ” to switch to next mode. Press “(!)” to save and exit advanced setting mode.
Code | Meaning | Default value | |
01 | Temp. calibration | -9.9~9.9’C(-9~9’F) | -1’C |
02 | Temp. Dif. | 0.5~1O’C(1~1O’F) | ±1’C |
03 | Temp. upper limit | 5~95’C(41 ~199’F) | 50’C |
04 | Temp. lower limit | 5~47’C(41 ~117’F) | 5″C |
05 | Frost protection | ON: frost protection on OFF: frost protection off | OFF ·c |
06 | Temperature unit | °C/°F | |
09 | flOJ’JTTTiing ootting | 12345: 5/2 week mode 123456: 6/1 week mode 1234567: 7/0 week mode | 12345 |
12 |
Child-lock | 00: ChikHock inactivate when roeen off, lock all when chikHock activate 01: ChikHock activate when roeen off, lock all when chik:1–lock activate 02: ChikHock activate when roeen off, lock all except Fai Sr-eoo, Up and Down when chikHock activate 03: ChikHock activate when roeen off, lock all except PcM.e- on/off when chik:1–lock activate |
00 |
13 | Power-on-reset | 00: Power OFF 01: Power ON 02: The last status before power loss | 02 |
19 | Reset | Press “A”for 3 seconds to reset |
The installation distance between the thermostat and the receiver does not exceed 100m (the distance can be judged according to the actual network coverage)
Tip: There are many ways to install the RF thermostat,
* Note: two power supply methods
3×5 Alkalibatterien
The thermostat operates in full capacity in areas with the altitude of less than 2500 above sea level. Power rating of external load should be less than or equal to 80%rated power of thee thermostat in areas with altitude of 2500m to 4200m.
Tip: Support one RF thermostat to pair with multiple RF receivers. After the pairing is successful, you need to short-press the “power button to exit the pairing mode
Download Smart Life APP
After waking up the speaker, you can say:
Amazon Alexa : Alexa, Turn on the HEATER
Google Assistant: OK google
*Attention: ” HEATER is the device name, you can also name it yourself.
The temperature unit of thermostat and smart speaker must be identical.
Download Manual
Beok BOT-R9B-WIFI Smart Thermostat User Mnaual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…