D-508F digital non-programmable thermostat is designed to control either ambient(air) temperature (A Mode) or floor temperature (F Mode) or a combination of ambient temperature with floor temperature limits(AF Mode). An auxiliary remote sensor is provided to measure slab temperature in order to control the floor temperature(within maximum and minimum limits in AF Mode). It can also be used for sensing the outdoor temperature
Slide Switch Configuration
The Slide Switches are located at the back of the control module(see Figure 1).
Note:
The sensor wires can be extended by conventional wires.
Power-up
As soon as the thermostat is powered, all the LCD segments are displayed. Then it undergoes a series of tests before displaying the actual temperature.
Floor Minimum and Maximum limits(AF Mode only)
The thermostat generally turns On or Off to control the ambient temperature. However, if the floor temperature drops below the set minimum floor temperature limit, the thermostat will turn heating On regardless of the ambient temperature. If the floor temperature rises above the maximum limit, the thermostat will turn heating Off regardless of the ambient temperature to maintain the floor within the desire limit. This setting ensures a minimum floor temperature at all times. The maximum limit is to avoid damage to your floor and for added safety.
Note: The floor minimum limit cannot be set to a higher value than the maximum limit.
SETTING THE THERMOSTAT
QuickSet Feature:
Quickset allows the user to change the setpoint temperature instantly without entering the setting mode. Simply press UP (increase) or Down (decrease) key during the normal operating mode. When the Up/Down key is pressed, the setpoint is flashing on the upper right hand corner of the LCD display to indicate that the setpoint value can be changed. Press the UP/Down key again to adjust the setpoint (press and hold for auto repeat function). Just walk away when finish and it will return to normal operating mode after 30 seconds.
Setting Mode
Steps | Procedures | Description | LCD Display | |||||
Step 1 | To start setting, press the SET key for 3 seconds to access the setpoint mode. The LCD will display the current setpoint (flashing). Then press either the Up key to increase or the Down key to decrease the setpoint to the desired setting. An example of LCD display in AF mode is shown. | Setpoint Temperature Default setting: 70°F(21°C) for A or AF mode, 82°F(28°C) for F mode. | | |||||
Step 2 | Press SET key again to access the differential mode. The LCD will display the current differential (blinking). Then press either the Up key to increase or the Down key to decrease the differential to the desired setting. Selection value: 0.5, 1.0, 1.5, 2.0 | Differential Temperature Default setting: 1°F(1°C) | ||||||
Step 3 | Press SET key again to access the Outdoor sensor. LCD will display the current | Outdoor sensor: On or Off | ||||||
(A mode only, otherwise, skip this step) | setting: Off (blinking) Then press either the Up key or Down key to toggle between On and Off. | Default setting: Off | ||||||
Step 4 | Press SET key again to access the Maximum Floor limit. The LCD will display the | Floor maximum limit | ||||||
(AF mode only, otherwise skip this step) | current setting (blinking). Then press either the Up key to increase or the Down key to decrease the limit to the desired setting. | Default setting: 82°F(28°C) | ||||||
Step 5 (AF mode only, otherwise skip this step) | Press SET key again to access the Minimum Floor limit. The LCD will display the current setting (blinking). Then press either the Up key to increase or the Down key to decrease the limit to the desired setting. | Floor minimum limit Default setting: 40°F(5°C) | Floor | | ||||
Step 6 | Press SET key again to access the System Mode. LCD will display the current mode: Heat (blinking) Then press either the Up key or Down key to toggle between Heat and Off. | System Mode: Heat or Off Default setting: Heat | ||||||
SYSTEM | ||||||||
Heat | ||||||||
Step 7 | Press SET key again to access the backlit mode. LCD will display the current mode, Auto (blinking). Then press either the Up key or the Down key to toggle between the Auto, On, Off designation. Press SET key again to go back to normal operating mode. Note: In Auto Mode, backlit is turned on for 60 seconds when any key is pressed. | Backlit mode: Auto, On or Off Default setting: Auto | |
View Setting Mode
Press both Up and Down keys at the same time to review the current control settings. “VIEW MODE” appears on the upper left corner of the LCD. Then Press (or Up) key to scroll through the settings in the same order as Setting Mode (Setpoint, Differential, Heat/Off, Backlit etc.). To exit to normal mode, press one more time from the last setting (e.g. Backlit) or press both Up and at the same time. In this mode, the settings
cannot be changed.
Turning On and Off the Heating System
In the heat mode, the relay is operated to maintain the temperature of the zone. The control output will turn on when the sensor temperature falls to the setpoint temperature minus half the differential amount. The control output will turn off as the temperature rises to the setpoint plus half the differential amount.
During the normal operating mode
! To disable or enable the relay output, press the power button once(eg. 1 second). LCD indicates a flashing “Heat” or “Off” under the “System” heading. Press the power button again to toggle between “Heat” to enable and “Off” to disable the relay output. After 30 seconds, the system returns to normal operating mode. ! To completely power off the thermostat, press the power button for three seconds. Press the power button again to turn back on the thermostat.
Keypad Lock
Keypad can be locked to prevent tempering by unauthorized personnel. This is done by pressing SET , Up and Down keys at the same time for three seconds. A lock symbol appears on the lower LCD screen which indicates that the keypad is locked. Then input from the keypad is disabled. Press SET, Up and Down keys at the same time again for another three seconds to unlock the keypad. The lock symbol disappears from the screen. Factory setting: unlock
Error Messages | |
Sensor Error Er1 | Internal sensor is open or short circuit. Replace the thermostat |
Sensor Error Er2 | External sensor is open or short circuit. Replace the external sensor. In A mode, if outdoor sensor is set to ON and no sensor is connected. |
Sensor Error Er3 | EEPROM (memory) data has been corrupted. Replace the thermostat. |
HHH | The measured temperature is above the upper display range. |
LLL | The measured temperature is below the lower display range. |
For more product information, please visit: www.azeltec.com
P.O. Box 53138, 10 Royal Orchard Blvd.
Thornhill, Ontario, Canada L3T 7R9
Ph: 905-223-5567 Fax: 905-223-3778
Email: info@azeltec.com
Download Manual:
AZEL D-508F Non-Programmable Digital Thermostat INSTRUCTION MANUAL
AZEL D-508F Non-Programmable Digital Thermostat INSTRUCTION MANUAL
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…