Read the entire document
The thermostat provides three temperature control modes:
A mode: | • controls the ambient temperature |
F mode: | • controls the floor temperature |
AF mode: | • controls the ambient temperature and limits the floor temperature |
See page 8 on how to select the temperature control mode setting.
* Use this switch to disable heating (e.g. in the summer).
Power | Terminals 1 & 5 |
Load | Terminals 2 & 4 (see note 1) |
Pilot Wire | Terminal 3 (see note 2) |
Floor sensor | Terminals 6 & 7; no polarity (see note 3) |
NOTE 1 If a contactor is used between the thermostat and the load, install a snubber at the contactor’s coil terminal to ensure the proper operation of the thermostat.
NOTE 2 Optional (see page 10).
NOTE 3 For the proper operation of the thermostat, the floor sensor must be centered between two heater wires having a maximum temperature of 80°C (176°F). The floor sensor wire must not cross any heater wire or be placed close to it.
NOTE 4 Ensure that the wires are tightly secured to the terminals. Apply a minimum torque of 0.5 Nm (4.4 Lb/in) when tightening the screws.
NOTE 5 The terminals are designed to handle a cross-section of wire measuring 0.33 to 3.1 mm2.
Position the switch, on the back of the thermostat faceplate, according to your application.
Type | Switch Position | Application |
A | Up | Controls the ambient temperature |
F | Down | Controls the floor temperature |
AF | Up | Controls the ambient temperature and limits the floor temperature |
Use two potentiometers on the back of the thermostat faceplate to set the minimum and maximum temperature limits. Use a flat-tip screwdriver to rotate the potentiometers until the notch points to the desired temperature limit.
Depending on your application, the potentiometers limit the following temperature:
TH131 accepts the six following pilot wire orders.
ORDER | SIGNAL | DESCRIPTION |
Comfort | No signal | Maintain temperature at setpoint |
Reduced setpoint (3.5k setback) | Maintain temperature at 3.5°C below the setpoint | |
frost protection | Maintain temperature at 7°C | |
Off | Stop heating | |
1k setback | Maintain temperature at 1°C below the setpoint | |
2k setback | Maintain temperature at 2°C below the setpoint |
Resideo warrants this product, excluding battery, to be free from defects in workmanship or materials, under normal use and service, for a period of three (3) years from the date of first purchase by the original purchaser. If at any time during the warranty period the product is determined to be defective due to workmanship or materials, Resideo shall repair or replace it (at Resideo’s option).
If the product is defective,
Resideo’s sole responsibility shall be to repair or replace the product within the terms stated above. RESIDEO SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY RESIDE MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE THREE-YEAR DURATION OF THIS WARRANTY. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.
This warranty gives you specific legal rights, and you may have other rights which vary from state to state. If you have any questions concerning this warranty, please write Resideo Customer Care, 1985 Douglas Dr, Golden Valley, MN 55422 or call 1-800-468-1502.
1985 Douglas Drive North, Golden Valley, MN 55422
33-00048EFS—03 M.S. Rev. 05-20 | Printed in the United States
© 2020 Resideo Technologies, Inc. All rights reserved.
The Honeywell Home trademark is used under license from Honeywell International, Inc.
This product is manufactured by Resideo Technologies, Inc. and its affiliates.
Download manual:
aube Electronic Thermostat TH131 Owner’s Manual
Aube Technologies TH131 Electronic Thermostat Owner’s Manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…