Press DAY, HOUR and MIN keys to adjust the time and day.
TO MODIFY HEATING AND COOLING PROGRAMS
OPERATING MODES
Shows the number of hours that the system has operated since the last filter change. Prevents freezing during your absence.
TEMPERATURE SPAN ADJUSTMENT
Press PROG key while RETURN key is pressed in
This thermostat can replace most common residential thermostats and is designed to be used with electric, gas or oil heating and air conditioning systems using 24 volts control and relay current up to 1.0 ampere.
Several useful functions and operating modes have been incorporated to adapt a variety of customer needs: besides all the features associated with the state of the art programmable thermostat, you’ll find on TH123:
To protect the compressor from damage and wear by cycling on and off too rapidly, the TH123 incorporates a minimum five (5) min-utes delay between cooling cycles.
If you have any questions concerning the installation or programming of the thermostat, please call our technical assistance at 1-800-831-AUBE or for the Montreal area, (450) 358-4600 from 8:30 AM to 5:00 PM, Monday through Friday, Eastern time.
This thermostat has been designed for simple and quick installation requiring only a few tools.
REQUIRED MATERIAL
REMOVING YOUR OLD THERMOSTAT
WARNING: To avoid electric shock, turn off the power of the heating and cooling system at the main power box in your home.
Read the following instructions carefully before disconnecting the wires.
Note: If your old thermostat has only two (2) wires connected to it (heating system only), simply disconnect the two wires from the wall plate, skip over steps 1 and 2 in the Wire labelling section and go on to step 3.
WARNING: After removing the wall plate, if you find that it is mounted on a junction box (e.g. a box similar to one behind a light switch or electric outlet), 240 volts circuit may be present and there is a danger of electric shock. Please consult a qualified electrician.
Note: For a new installation, choose a mounting location about five feet (150 cm) above the floor in an area with good air circulation and away from:
Drafts or dead air spots, Air ducts, radiant heat from the sun or appliances, Concealed pipes and chimneys.
Mounting the thermostat onto the wall
DISPLAY IN °C OR °F
After the installation of the battery, if you want to change unit of the degree displayed, follow these instructions (see the illustration):
CONNECTING THE LABELLED WIRES TO THE THERMO-STAT
The TH123 thermostat can be used with any single stage heating and cooling system. You cannot directly use this thermostat on mul-tiple stages heating or cooling system, millivolt system, heat pump or 240 VAC control system. It can control some of those systems by installing an isolation relay and a 24-volt transformer.
HEATING SYSTEM TYPE
The heating system type selector is located below the wire connec-tor. Start first by keeping the selector at default position Hg. If the fan switch is at FAN AUTO position and the fan doesn’t start when the thermostat turns on the furnace, place the type selector at posi-tion He.
WIRE HEATING SYSTEM
WIRE HEATING SYSTEM WITH FAN CONTROL
WIRE HEATING AND COOLING SYSTEM
WARNING: Remove jumper between terminals Rh and Rc: Both 24 volts returns of the transformers must be connected together in order to have the fan working with the heating and the cooling system. *Otherwise, the fan will only work with the cooling system. *(both transformer supplies, 120/240 vac, must be the same).
REMOTE ECONO MODE
Connect the auxiliary system (alarm or domotic system for instance) between the terminals X (positive) and C (negative). The signal from those systems must be 12 to 24 VAC or VDC.
FIRST POWER-UP
The thermostat has four (4) operating modes: AUTOmatic, MANual, TIMER ECONO and REMOTE ECONO.
AUTO
The AUTOmatic mode executes in sequence (hourly) the recorded programs.
MAN
The manual mode allows the user to bypass the programming.
TIMER ECONO
The TIMER ECONO mode holds the ECONO temper-ature set point until user predetermined time and day is reached. Then, the thermostat turns to AUTOmatic mode.
This operating mode avoids the user to reprogram his thermostat for a prolonged absence (up to one week) and allows for maximum savings.
REMOTE ECONO
An auxiliary system as your alarm or domotic system for instance, can turn your thermostat to ECONO mode. The thermostat holds the ECONO temperature set point as long as the signal of the auxil-iary system is applied.
The
When the auxiliary signal is removed, the thermostat returns to the previous operating mode (see wiring diagram).
This switch selects the functions: HEAT, COOL, and OFF.
The thermostat has an automatic return. When functions such as the time recording, the program recording, etc. have not been completed by pressing the RETURN key, the thermostat will automatically exit those functions after five (5) or ten (10) seconds.
TIME AND DAY ADJUSTMENT
PRE-RECORDED PROGRAMS
This thermostat has four (4) preprogrammed heating and cooling programs for weekday and two (2) for weekend. They can be used as is or you can modify them at your convenience.
Weekday programs (Mon…. Fri.)
Temperature Setpoints | |||
Prog | Hour | Heating | Cooling |
1 | 6:00 AM | 21°C (70°F) | 23°C (73°F) |
2 | 8:30 AM | 21°C (70°F) | 23°C (73°F) |
3 | 4:00 PM | 21°C (70°F) | 23°C (73°F) |
4 | 11:00 PM | 17°C (63°F) | 27°C (80°F) |
Weekend programs (Sat.& Sun.)
1 | 6:00 AM | 21°C (70°F) | 23°C (73°F) |
2 | 11:00 PM | 17°C (63°F) | 27°C (80°F) |
PROGRAMMING MODIFICATION
PROGRAMMING SCHEDULE
Use following programming schedule as a memorandum before programming or changing a program by writing down your schedule of heating and cooling.
Weekday programs (Mon…. Fri.)
Temperature Setpoints | |||
Prog | Hour | Heating | Cooling |
1 | |||
2 | |||
3 | |||
4 |
Weekend programs (Sat.& Sun.)
1 | |||
2 |
The factory set temperature span is 1°C (2°F). For example, if the temperature set point is 20°C (68°F), the heating system will turn on at 19.5°C (67°F) and turn off at 20.5°C (69°F).
This span is programmable. You can choose between 0.5°C (1°F), 1°C (2°F), 1.5°C (3°F) and 2°C (4°F).
To review or to change the temperature span:
AUBE TECHNOLOGIES INC. ONE (1) YEAR LIMITED WARRANTY
This product is warranted against material defects and workmanship in normal use for a period of one year, from the date of the original purchase from authorized dealers. Warranty does not cover transportation costs. Nor does it cover a product subjected to misuse or accidental damage. This limited warranty is in lieu of all other warranties, obligations or liabilities expressed or implied by the company. In no event shall AUBE Technologies inc. be liable for consequential or incidental damages resulting from installation of this product.
Within this period, any product proven defective in normal use will be repaired or replaced at AUBE’s option, without charge for either parts or labour, provided that the defective product with the original sale receipt is returned to the original dealer or is shipped prepaid, insured and addressed to:
AUBE TECHNOLOGIES INC.
Service centre
705, Montrichard Avenue
Saint-Jean-sur-Richelieu (Quebec)
Canada J2X 5K8
(450) 358-4600 or 1-800-831-2823
Download manual:
Aube Technologies TH123 Programmable Thermostat User manual
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…