This programmable thermostat can be used to control an electric heating system such as an electric baseboard heater, a radiant ceiling, a radiant floor, a convector, etc. The thermostat cannot be used with the following:
SUPPLIED PARTS:
TURN OFF THE POWER TO THE HEATING SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK.
NOTE: Always keep the thermostat’s vents clean and unobstructed. THE INSTALLATION MUST BE PERFORMED BY AN ELECTRICIAN.
The configuration switches are on the back of the thermostat. The factory settings are indicated by the gray cells in the following table.
SW1 | Early Start a | Off | On |
SW2 | Temperature/time format b | °C / 24-hour | °F / 12-hour |
SW3 | Cycle length c | 15 seconds | 15 minutes |
SW4 | Not used | – | – |
Power-up
Upon power-up, the thermostat is in manual mode (
Setpoint
The thermostat normally displays the actual temperature. To view the setpoint, press the or button briefly. The setpoint will appear for the next 5 seconds. To change the setpoint, press the or button until the desired temperature is displayed. To scroll faster, hold the button. Using a preset temperature
The thermostat has 3 preset temperatures
Storing a preset temperature
To store the Comfort or Economy temperature:
Set the desired temperature using the or button. Press and hold the appropriate button ( or ) for approximately 3 seconds until the corresponding icon is displayed.
Automatic – The temperature is set according to the programmed schedule. To place the thermostat in this mode, press Mode until is displayed. The icons of the current period and preset temperature are also displayed.
Temporary Bypass: If you modify the setpoint (by pressing the
Manual – The programmed schedule is not used. The temperature must be set manually. To place the thermostat in this mode:
The schedule consists of 4 periods per day which represents a typical weekday. You can program the thermostat to skip the periods that do not apply to your situation. For example, you can skip periods 2 and 3 for the weekend
The Comfort (
To modify the schedule
During a power outage, the settings are stored in memory. However, only the thermostat’s clock must be re-adjusted if the power failure lasts more than 2 hours. When the power comes back, the thermostat will return to the operating mode that was active prior to the power failure.
PROBLEM | SOLUTIONS |
Thermostat is hot. | This condition is normal. Under normal operation, the thermostat housing can reach a temperature between 35°C (95°F) and 40°C (104°F). |
Wrong temperature is displayed. | The thermostat is exposed to air draft. Eliminate the draft. The sticker on the thermostat’s screen has not been removed. |
Wrong time is displayed. | The thermostat was without power for more than 2 hours. |
Temperature does not change according to the programmed schedule. | Check that the thermostat is in Automatic mode. Check the schedule and clock set- tings. |
Display disappears and reappears after a few minutes. | The thermal protection device on the heater is open. This can happen after a power failure or if the heater is obstructed by furniture or curtains. |
Display looks faded when heating is acti- vated | The heating system is less than the required minimum load. This thermostat cannot be used below that rating. |
Aube warrants this product, excluding the battery, to be free from defects in the workmanship or materials, under normal use and service, for a period of three (3) years from the date of purchase by the consumer. If at any time during the warranty period, the product is determined to be defective or malfunctions, Aube shall repair or replace it (at Aube’s option).
If the product is defective,
This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Aube that the defect or malfunction was caused by damage that occurred while the product was in the possession of a consumer. Aube’s sole responsibility shall be to repair or replace the product within the terms stated above. AUBE SHALL NOT BE LIABLE FOR
ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some provinces and states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you. THIS WARRANTY IS THE ONLY EXPRESS WARRANTY AUBE MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED
WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE THREE-YEAR DURATION OF THIS WARRANTY. Some provinces and states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. This warranty gives you specific legal rights, and you may have other rights which vary from one province or state to another.
Customer Assistance
If you have any questions about the product installation or operation or concerning the warranty, contact us at 705 Montrichard
Saint-Jean-sur-Richelieu, Quebec
J2X 5K8 Canada
Tel.: (450) 358-4600
Toll-free: 1-800-831-AUBE
Fax: (450) 358-4650
Email: aube.service@honeywell.com
For more information on our products, go to www.aubetech.com
Download Manual:
Aube Technologies OTH800D Nonprogrammable Thermostat Installation Guide
Aube Technologies OTH800D Nonprogrammable Thermostat Installation Guide
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…