WARNING
Do not use sharp instruments to press the touch screen. Only use your fingertips.
Select system mode
(EM HEAT/HEAT/OFF/COOL/AUTO)
Press [MODE] to select:
Change temperature set point
Press
(See Program Schedule Holds on pages 17-19 for more information.)
When the fan mode is changed during a program event it remains in that mode until the next event starts. The fan must be programmed to FAN ON in the schedule to run continuously through all events.
Press [FAN] to select:
Press [MENU] to enter the main menu.
Press [CLEAN SCREEN] to disable the touch screen for 30 seconds for cleaning.
Note: Use a soft damp cloth to clean the screen. Use water or household glass cleaner. Do not spray liquids directly on the screen.
Maintenance reminders are set up by the installer to indicate when the equipment is due for service. If a maintenance reminder is displayed, call your HVAC dealer for service. They can be cleared by pressing [MENU] to enter the main menu, then [Next] to clear each reminder.
Batteries are not required for proper operation. The thermostat is a 24VAC-powered device with a battery backup for the clock.
The thermostat has a memory backup that saves the thermostat’s settings in case of a power interruption. The system settings will be retained but the clock will reset after 90 seconds with no battery or AC power. Replace the batteries every year or when the low battery indicator comes on.
The reset button located under the battery cover can be used to reset the thermostat to factory defaults.
WARNING
The reset button should only be used by the installer.
The Model 8800 has the option of being configured as a humidistat that can control a humidifier and dehumidifier.
Press [MENU] to enter the main menu.
Press [SETUP] to enter the setup menu.
Press [Next] or [Back] to page through the settings, until you get to the Humidistat Mode Setting (the setting is displayed in the message center).
The daily schedule is split into four events:
Event designator | Start time | Set temperature | fan | |
Heat | Cool | |||
WAKE | 6:00 AM | 70°F (21°C) | 78°F (26°C) | AUTO |
LEAVE | 8:00 AM | 62°F (17°C) | 85°F (29°C) | AUTO |
RETURN | 5:00 PM | 70°F (21°C) | 78°F (26°C) | AUTO |
SLEEP | 10:00 PM | 62°F (17°C) | 82°F (28°C) | AUTO |
Optionally, the thermostat can be set to a two-event or commercial schedule. (See Setup Menu on page 20.)
Event designator | Start time | Set temperature | fan | |
Heat | Cool | |||
wAkE/oCCUPiED | 6:00 AM | 70°F (21°C) | 78°F (26°C) | AUTO |
LEAVE/UNoCCUPiED | 10:00 PM | 62°F (17°C) | 82°F (28°C) | AUTO |
The Progressive Recovery feature allows the thermostat to activate the heating and cooling equipment prior to an event in order to reach the desired temperature at the start of the next scheduled event.
Example: If the WAKE time is 6 am, and the set temperature is 70°, the heat will come on before 6 am, so the temperature is 70° by the time you wake at 6 am.
Press [MENU] to enter the main menu.
Press [SET SCHEDULE] to enter scheduled programming.
Press
Note: This step is not displayed for weekday/weekend schedules.
Press [Next], then
Press [Next], then
Press [Next], then [FAN] to set the fan mode of the first event.
Press [Next] to advance to the next event.
Repeat above process for each remaining event.
Press [DONE] to save the schedule for the day.
The thermostat will display the COPY option.
Press [COPY] to copy the schedule of the day just programmed to any other day.
OR
Press [CANCEL] to proceed to the next day and repeat the above process.
Program schedule holds – temporary
Temporary program hold
Press or to immediately adjust the temperature when the schedule is running. This will temporarily hold the temperature setting until the next scheduled event.
Press or to adjust the end time of the hold. If end time is not adjusted, the Temporary Hold will end at the start of the next event.
To cancel the Temporary Hold, press [CANCEL HOLD].
Permanent program hold
Press [HOLD] to permanently hold the temperature at its current setting while the schedule is running. This will override the temperature settings for all events. With the thermostat in Permanent Hold, the temperature setting and fan mode can be adjusted and will stay at that setting until the hold is cancelled.
To cancel the Permanent Hold, press [CANCEL HOLD].
Vacation program hold
This energy saving feature allows you to suspend the programmed schedule for extended periods of time. The temperature you select will be maintained 24 hours a day until the vacation program hold end date and time.Once the end date and time have been surpassed, the previously programmed schedule will resume. If you return earlier than expected, press [CANCEL HOLD] to resume the programmed schedule.
The following table is the list of the settings and their details. Default settings are shown in bold.
System setting | Description | the factory default setting (bold) and setting range |
HUMiDiSTAT MoDE | (only available if controller type is set to humidistat) | HUMiDiFy DEHUMiDiFy AUTO Off |
TEMPERATURE SCALE | Set the thermostat to Fahrenheit or Celsius mode | Fahrenheit CELSIUS |
AUTo DAyLigHT SAViNgS | Enable or disable auto daylight savings | MARCH – Second Sunday in March to the first Sunday in November APRiL – First Sunday in April to the last Sunday in october oFF |
BACkLigHT iNTENSiTy | Backlight intensity as a percentage of full on | 100 pERCENT Selection of 0 – 100% |
EVENTS PER DAy | Number of program events per day | fOUR EVENTS pER DAy Two EVENTS PER DAy |
SECURiTy | Enable PiN code security feature (only available if enabled in installer setup) | DISAblED ENABLED |
SECURiTy PiN | Sets security PiN code. The thermostat can also be accessed with the master PiN 7777 (only available if Security is enabled) | #### 4-digit numeric PiN |
System setting | Description | factory default setting (bold) and setting range |
LoCkoUT TyPE | Level of lockout (only available if Security is enabled) | Off: No lockout PARTiAL lockout FULL lockout |
MoDE LoCkoUT | System mode lockout setting (only available in partial lockout) | DISAblED ENABLED |
FAN LoCkoUT | Fan mode lockout setting (only available in partial lockout) | Off: No lockout TiMED: changes revert after temporary change period FULL: no fan mode changes allowed |
SETPoiNT LoCkoUT TyPE | Setpoint lockout setting (only available in partial lockout) | Off: No lockout TiME-LiMiTED: changes revert after temporary change period RANgE-LiMiTED: set by max setpoint lockout TiME AND RANgE: set by max setpoint lockout and temporary change period FULL: no setpoint changes allowed |
MAX SETPoiNT CHANGE IN LOCKOUT | Setpoint range limit for temperature and humidity adjustments (only available in partial lockout) | ±5° f or C, ±5% RH oFF to ±20° F or C, oFF to ±20% RH |
TEMPoRARy CHANgE PERioD | Time-limited lockout temporary change period (only available in partial lockout) | 60 MINUTES 0 to 255 MINUTES |
DiSPLAy REMoTE SENSORS | Enables the display of Support Module temperature and humidity values in the message center . | DISAblE ENABLE |
Your Research Products Corporation Aprilaire® Thermostat unit is expressly warranted for five (5) years from date of installation to be free from defects in materials or workmanship.
Research Products Corporation’s exclusive obligation under this warranty shall be to supply, without charge, a replacement for any thermostat which is found to be defective within such five (5) year period and which is returned, together with the date of installation, no later than thirty (30) days after said five (5) year period by you to either your original supplier or to Research Products Corporation, Madison, Wisconsin 53701. THIS WARRANTY SHALL NOT OBLIGATE RESEARCH PRODUCTS CORPORATION FOR ANY LABOR COSTS AND SHALL NOT APPLY TO DEFECTS IN WORKMANSHIP OR MATERIALS FURNISHED BY YOUR INSTALLER AS CONTRASTED TO DEFECTS IN THE THERMOSTAT ITSELF. IMPLIED WARRANTIES OF MERCHANTABILITY OF FITNESS FOR A PARTICULAR PURPOSE SHALL BE LIMITED IN DURATION TO THE AFORESAID FIVE-YEAR PERIO D. RESEARCH PRODUCTS CORPORATIO N’S LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, OTHER THAN DAMAGES FOR PERSONAL INJURIES, RESULTING FROM ANY BREACH OF THE AFORESAID IMPLIED WARRANTIES OR THE ABOVE LIMITED WARRANTY IS EXPRESSLY EXCLUDED. THIS LIMITED WARRANTY IS VOID IF DEFECT(S) RESULT FROM FAILURE TO HAVE THIS THERMOSTAT INSTALLED BY A QUALIFIED HEATING AND AIR CONDITIONING CONTRACTOR. IF THE LIMITED WARRANTY IS VOID DUE TO FAILURE TO USE A QUALIFIED CONTRACTOR, ALL DISCLAIMERS OF IMPLIED WARRANTIES SHALL BE EFFECTIVE UPON INSTALLATION. Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages, so the above exclusions or limitations may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state. This equipment if installed in strict accordance with the manufacturer’s instructions complies with the limits for a Class B computing device pursuant to Subpart J of Part 15 of FCC Rules.
Please…Take a few minutes to visit us online at www.aprilaire.com to register your Aprilaire product.
If you do not have online access, please mail a postcard with your name, address, phone number, product purchased and date of purchase to: Research Products Corporation, P.O. BOX 1467, Madison, WI 53701
Your Warranty Registration information will not be sold or shared outside of this company.
Download Manual
Aprilaire 8600 Touchscreen Thermostat Owner Guide
other manuals
Aprilaire 8600 Touchscreen Thermostat Installation Instruction
Aprilaire 8600 Touchscreen Thermostat Product Specification Guide
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…