The thermostat wiring is factory installed by the OEM (Original Equipment Manufacturer). RV Products suggests the thermostat wiring be a minimum of 18 gauge. The thermostat is intended for use with a 12 VDC control circuit that does not exceed 1 amp. The thermostat is equipped with a replaceable 2 amp fuse located on the base of the thermostat. The fuse is designed to “open” if the circuit is mis-wired or if there is a short in the system. Before replacing the fuse, the cause of the failure must be located and corrected.
Caution This thermostat should be installed by trained technicians only. Adhere to all local and national codes and ordinances. Disconnect all power to the system before installing, removing, or cleaning.
The display indicates the mode and the room temperature. When the mode button is pressed once, the thermostat will wake. If your thermostat is equipped with a backlight, the backlight will illuminate. When the mode button
There is a three minute anti-short cycle for cooling. After the cooling system has been de-energized, the system will not energize again for three minutes, to protect your compressor. To bypass the anti-short cycle, change the mode to OFF.
Note: Operating your cooling system when the outdoor temperature is below 50°F can cause damage to your cooling equipment.
Temperature | ||
Mode | Range | |
°F | °C | |
Cooling (set) | 33°F to 99°F | 1°C to 37°C |
Heating (set) | 33°F to 99°F | 1°C to 37°C |
Heat and Cool – 9430*351*, 9430*353*
ELECTRICAL SHOCK HAZARD – Turn off power at the main service panel by removing the fuse or switching the appropriate circuit breaker to the Off position before removing the existing thermostat.
A. THERMOSTAT LOCATION
This thermostat is a sensitive instrument. For accurate temperature control and comfort, the following considerations should be taken into account:
B. INSTALLING THE THERMOSTAT
Pairing a previously paired thermostat
ZONE NAME: Assigns a name or description to the thermostat (maximum of 7 characters).THERMOSTAT ID: Displays thermostat’s 6 digit ID
FUNCTIONS: Displays available modes. SET: Saves assigned zone name/ description.
CANCEL: Reverts to main screen.
REMOVE THERMOSTAT: Removes thermostat from the RV Climate app.
Removing a previously paired thermostat
The chart below shows the system functions with both COOL ONLY and HEAT/COOL RVP thermostats. After the entire air conditioning and heating system is installed, check each position’s function. The Cool Only thermostat will not have heat functions.
Mode | Call | Operation | |
1 | Fan Low | No | GL-Fan Low (Gray) energized |
2 | Fan Hi | No | GH-Fan High (Green) energized |
3 | Cool On High | No | GH-Fan High (Green) energized |
4 | Cool On High | Yes | GH-Fan High (Green) energized, Y-Compressor (Yellow) energized |
5 | Cool On Low | No | GL-Fan Low (Gray) energized |
6 | Cool On Low | Yes | GL-Fan Low (Gray), Y-Compressor (Yellow) energized |
7 | Cool Auto Low | No | No function occurs |
8 | Cool Auto Low | Yes | GL-Fan Low (Gray) energized, Y-Compressor (Yellow) energized |
9 | Cool Auto High | No | No function occurs |
8 | Cool Auto High | Yes | GH-Fan High (Green), Y-Compressor (Yel- low) energized |
9 | Heat Gas | No | No function occurs |
10 | Heat Gas | Yes | W-Furnace (White) energized |
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in
a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Contains FCC ID: WAP4110
A Division of Airxcel, Inc.
P.O. Box 4020, Wichita, KS 67204
www.Airxcel.com
Download manual:
AIRXCEL 9430-351 Thermostat INSTALLATION, OPERATION & APPLICATION GUIDE
AIRXCEL 9430-351 Thermostat INSTALLATION, OPERATION & APPLICATION GUIDE
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…