The CT100 communicating Z-Wave thermostat operates via a high-quality, easy-to-use touch screen. To set or adjust your CT100, simply touch your finger firmly to the screen. The screen will automatically light up and you will hear a “beep.” Do not use a sharp or metallic device; it will scratch the screen.
Statement of use: 100% Compatible with all popular residential HVAC systems; 24VAC single, two-stage conventional heating systems (gas/oil/electric), heat pumps with up to two stages of heat and two-stage auxiliary
heat(electric or fossil), zoned forced air and zoned hot water (2 or 3 wire), millivolt systems (with a 12-24 AC or DC source), one or two-stage cooling, and hybrid systems.
Before you operate the CT100 please get familiar with these basic control screens. All the CT100 functions are accessed through these screens: HOME, MENU, and MANUAL. The CT100 touch screen technology allows you to select (by touching) an item and change it using the +/- arrows or the time arrows.
The HOME screen is displayed when the unit is operating. Touching the HOME icon
To set a Mode:
Press the mode button on the front. The CT100 will step through the modes HEAT, OFF, COOL, OFF, AUTO, OFF in order.
MENU Screen
The MENU screen is the gateway to many functions or settings of the CT100. It is displayed when you press the MENU button. [See page 6 for details]
MANUAL Screen The Manual Screen control screen is where you can make
temporary changes to your CT100’s operation. From the HOME screen, touch the main temperature display to use this screen. [See page 9 for details]
Press MENU to access the following commands (from HOME screen).
Set time of day
Touch the Time of Day arrows to move the time selection forward or backward until it displays the current time. Touch and hold for faster setting.
Set oF-oC display
Touch the oF and it will toggle to oC.
Set audible chirp
Touch the musical note icon to select the chirp or no chirp.
Return HOME by touching the home icon.
Press MENU to bring up MENU screen.
TIME of DAY
Touch the left (down) or right (up) arrows next to the time display to set the current time (1 minute per touch). Touch and hold the arrow for fast time set (15 minute jumps).
SWING (HVAC cycling rate) This feature allows you to set the desired variance in temperature between the CT100 setting and the room temperature required before the heating or cooling system will turn on—Swing range: 0.5 to 4.0F (.25 to 2C). For example, if SWING is set to 2.0° F and the CT100 is set to 70°F Target Temperature, the heat cycle will start when room temperature drops to 68°F. Similarly, the cooling system will start when the room temperature increases to 72°F. The HVAC then runs and will shut off at the Target Temperature.
To set SWING:
Touch SWING.
Touch the left/right arrows to set the SWING from 0.5° to 4.0°F (.25 to 2C).
The HVAC will run more frequently at 0.5°F and less at 4.0°F. The default is 1°F.
Touch
Chirp set – Touch this to turn the audible chirp sound on or off. F
C Set – Touch this to switch the temperature display scale from oF to oC .
LOCK (The CT100 has 2 lock modes)
Touch icon for 5 seconds; the unit will go into the PARTIAL lock mode. The user can temporarily override the CT100 target with the +/- buttons only. (1 bar)
For FULL lock: Touch the
To UNLOCK, Press MENU.
Touch and hold
Then touch and hold the icon
Touch
CALIBRATE Your thermostat was accurately calibrated at the factory to ±1° F of actual ambient temperature. You do have the option, however, to change the display temperature to match that of a previous thermostat, or to match another thermostat already in your home. The range of change is from -6°F to +6°F or -3°C to +3°C.
To change your Thermostat Calibration, touch MENU and then touch CALIBRATE.
Use the + / – to adjust the displayed temperature up or down, as desired.
The DELTA FACTOR that appears on the screen will also automatically increase or decrease
for each 0.5° (F or C) adjustment so you can see your change. The large display will show the modified temperature reading that will be displayed on the HOME screen and used as the new room temperature.
Touch
DIFF (Used for multiple stage systems only, not on screen for single stage)
The differential is the number of degrees between the room temperature and the Target Temperature at which the 2nd stage will be used. Default is 2°F , range is 2°F to 6°F (1°- 3°C).
Touch MENU and then DIFF. Use the arrows to set the DIFF.
Recommend 2°F for very cold climates and the 6°F for warm climates.
MANUAL Screen Functions
The CT100 has 2 manual override commands. The manual screen is accessed by touching the large current temperature display in the middle of the HOME screen.
IMPORTANT: The Mode must be in HEAT or COOL to access the manual screen.
TEMPERATURE Touch the +/- arrows tot select your desired Target Temperature. Touch HOME to return to operation.
EMER (in HEAT PUMP type)
If you set your CT100 for HEAT PUMP with auxiliary heat, EMER function is available on the MANUAL screen. If you touch EMER, it displays EMER|ON. Your HEAT PUMP is disabled and auxiliary heat is your sole source of heat. This manual override stays active until you toggle EMER off. Auxiliary heat is more expensive than the heat pump so use EMER only if the heat pump cannot keep up or is defective.
MODE Button
The mode button sets the CT100 to HEAT, COOL, AUTO, or OFF modes. Press it once to step to the next mode. If the CT100 is in OFF and you want to return to the mode you were previously in, touch the OFF indicator on screen.
FAN Button
The fan control is normally in AUTO mode, meaning that the fan operates automatically with the HVAC system and the thermostat. When the fan button is pressed the fan goes ON; the fan will run continuously in this manual override until switched back to AUTO by pressing the FAN button again.
[NOTE: Fan ON function is available in the OFF mode to allow simple ventilating.]
RESET button The RESET button re-boots the CT100 processor. It does not affect the target temperatures that have been stored in permanent memory.
Compressor Protection The CT100 has a minimum cycle time of 4 minutes to protect your compressor in cool and in heat pump (if you have one). The Home screen will show a small clock and A/C during this time and the compressor will not come on until the 4-minute delay is over.
Communicating Thermostat
The CT100 has a built-in Z-Wave radio. This allows your thermostat to communicate with other systems.
Network EXCLUSION
Z-Wave and Battery Power
When your thermostat is running on battery power, the Z-Wave radio will turn off to help conserve battery life. The CT100 Z-Wave radio module supports Z-Wave beaming, which allows other devices in the network to wake up the Z-Wave module and accept commands, and then go back to sleep. The node type is fixed during network inclusion. If C-Wire is not present and the thermostat is battery-powered during network inclusion, the thermostat will remain a frequent listening routing slave
(FLiRS) node until the thermostat is removed from the network via network exclusion.
Z-Wave and C-Wire Power
When your thermostat is running on C-Wire power, the Z-Wave radio will stay on and actively help in routing messages within the z-wave network. The node type is fixed during network inclusion.
If C-Wire is present and powered during network inclusion, the thermostat will remain an always listening node until the thermostat is removed from the network via network exclusion.
Caution HVAC Setup and Z-Wave
Do not change the HVAC setup or HVAC selection switches if the thermostat is included to the Z-Wave network. The HVAC system must be changed, first EXCLUDE the thermostat from the network, change the HVAC setup, and INCLUDE the thermostat to the network.
Download Manual:
2GIG CT100 Radio thermostat Operation Guide
Johnson Controls T7000e LCD Digital Thermostat Johnson Controls T7000e LCD Digital Thermostat Installation Guide
Honeywell T8635L Microelectronic Communicating Programmable Thermostat Honeywell T8635L Microelectronic Communicating Programmable Thermostat USER’s GUIDE
Hetta HS01RF WIRELESS THERMOSTAT Kit PAIRING INSTRUCTIONS Insert batteries into the Thermostat. Ensure that the…
HEAT-MAT NGT-567-0010 Underfloor Heating Thermostat Menu Introduction The NGT thermostat can switch your underfloor heating…
Honeywell RLV450 PROGRAMMABLE THERMOSTAT READ BEFORE INSTALLING DESCRIPTION * LP appears only for the first…
Honeywell RLV431 Programmable Thermostat Description The RLV431 thermostat can be used to control an electric…