WarmlyYours nSpiration Thermostat Tempzone Single wiring
For 120V & 240V Single Conductor TempZone with nSpire Touch Wi-Fi (UWG4), nSpire Touch (UDG4), nHance (UDG), nTrust (UTN4), nJoin (USG)
ELECTRICAL ROUGH-IN
FACEPLATE REMOVAL
REAR OF THE BASE
- MAT HAS NO POLARITY
- RED OR YELLOW INDICATORS ON COLD LEAD INDICATE THE “BEGINNING” OF THE MAT. WHITE INDICATORS SIGNIFY THE “END” OF THE MAT
- COLD LEAD IS 13” AT “THE BEGINNING” OF THE MAT, AND 26’ AT “END” OF THE MAT (20’ & 40’ LEADS ON 3’ WIDE MATS)
- ENSURE THAT ALL COLD LEADS PRESENT IN THE THERMOSTAT BOX ARE THE SAME DIAMETER
- DO NOT SHORTEN THE MAT
- DO NOT CUT THE HEATING WIRE
- ALWAYS TEST OHMS OF ROLE BEFORE, DURING, AND AFTER INSTALLATION
- ALWAYS TEST THE SENSOR AND VERIFY 8-15 K OHM RESISTANCE
- NEVER INSTALL ELECTRIC FLOOR HEATING UNDER PERMANENT FIXTURES
- THE INSTALLATION MUST COMPLY WITH ALL NATIONAL AND LOCAL ELECTRICAL AND BUILDING CODES, INCLUDING AUTHORITY HAVING JURISDICTION.
Installation Support • (800) 875-5285 • www.WarmlyYours.com