Tag: Heat Pump Thermostat

  • Dwyer  PLVT1 Digital Thermostat with Heat Pump Control Product Specifications Guide

    Dwyer PLVT1 Digital Thermostat with Heat Pump Control Product Specifications Guide

    Dwyer PLVT1 Digital Thermostat with Heat Pump Control  INTRODUCTION The Model PLVT1 Compact Digital Thermostat with Heat Pump directly controls the furnace, small boiler, air conditioner, circulator fan, and heat pump in commercial or residential buildings. A large easy-to-read LCD display shows the current temperature and the operating mode. In case of a power outage,…

  • Peco TH170 HEAT PUMP THERMOSTAT  User Manual

    Peco TH170 HEAT PUMP THERMOSTAT User Manual

    Peco TH170 HEAT PUMP THERMOSTAT   Preinstallation Considerations Thermostat Location – The thermostat should be used indoors only. It should be mounted on an inner wall 48” from the floor, in a location with freely circulating air, and where it will be responsive to changes in room temperature. Avoid mounting near heat-generating appliances (i.e. TV, heater,…

  • beca BHP-6000 Heat Pump Thermostat User Guide

    beca BHP-6000 Heat Pump Thermostat User Guide

    beca BHP-6000 Heat Pump Thermostat INTRODUCTION Thank you for your purchase. Please confirm that this product is suitable for your heating equipment before installation; *Before installation or maintenance, please make sure to keep the power off; *Please strictly follow the wiring diagram for wiring installation; *Installation to the wall, please confirm that the fasteners are…

  • GE Appliances RAK148D1 Heat Pump Digital Remote Thermostat Owner’s Manual

    GE Appliances RAK148D1 Heat Pump Digital Remote Thermostat Owner’s Manual

    GE Appliances RAK148D1 Heat Pump Digital Remote Thermostat Important safety information WARNING! Always turn off power at the main power supply before installing, cleaning or removing the thermostat. This thermostat is for 24 VAC applications only. Do not use on voltages over 30 VAC. All wiring must conform to local and national electrical and building…

  • Emerson 1F79-111 Non-Programmable Heat Pump Thermostat Installation Guide

    Emerson 1F79-111 Non-Programmable Heat Pump Thermostat Installation Guide

    Emerson 1F79-111 Non-Programmable Heat Pump Thermostat  YOUR THERMOSTAT REPLACES Description Heat Pump (No Aux or Emergency Heat) Yes Heat Pump (with Aux or Emergency Heat) Yes Standard Heat & Cooling Systems No Standard Heat Only Systems No Millivolt Heat Only Systems – Floor or Wall Furnaces No Standard Central Air Conditioning No Gas or Oil…

  • Honeywell T8011R Programmable Heat Pump Thermostat INSTALLATION INSTRUCTIONS

    Honeywell T8011R Programmable Heat Pump Thermostat INSTALLATION INSTRUCTIONS

    Honeywell T8011R Programmable Heat Pump Thermostat  APPLICATION The T8011R Heat Pump Thermostat provides 24 Vac control of a two-stage heating and one-stage cooling heat pump system with manual changeover from heat to cool. First stage heating and cooling cycle rates are fixed at 3 cph. The second stage heating cycle rate is selectable at 3,…

  • Honeywell CT70A Heat Pump Thermostat User Manual

    Honeywell CT70A Heat Pump Thermostat User Manual

    Honeywell CT70A Heat Pump Thermostat  Your Honeywell Thermostat Your new Honeywell CT70A Heat Pump Thermostat provides low voltage (24 Vac) control of two-stage heating and one-stage cooling in heat pump systems, using manual changeover. Light-emitting diodes (LEDs) provide emergency heat and auxiliary heat indication. Recycling Notice This control contains mercury in a sealed tube. Do…

  • EMERSON White-Rodgers 1F79 Non-Programmable Heat Pump Thermostat INSTALLATION INSTRUCTIONS

    EMERSON White-Rodgers 1F79 Non-Programmable Heat Pump Thermostat INSTALLATION INSTRUCTIONS

    EMERSON White-Rodgers 1F79 Non-Programmable Heat Pump Thermostat  YOUR THERMOSTAT REPLACES Description Heat Pump (No Aux or Emergency Heat) Yes Heat Pump (with Aux or Emergency Heat) Yes Standard Heat & Cooling Systems No Standard Heat Only Systems No Millivolt Heat Only Systems – Floor or Wall Furnaces No Standard Central Air Conditioning No Gas or…

  • Emerson 1F82-0261 Heat Pump Thermostat installation and operating instruction

    Emerson 1F82-0261 Heat Pump Thermostat installation and operating instruction

    Emerson 1F82-0261 Heat Pump Thermostat APPLICATIONS THERMOSTAT APPLICATION GUIDE Thermostat Configuration Options Thermostat Applications Maximum Stages Heat/Cool Heat Pump Single Stage Compressor Single Stage Compressor Heat Pump Systems – 1 Stage Aux/Emergency Heat 2/1 SPECIFICATIONS Electrical Rating: Battery Power or Hardwire………………………… 20 VAC, 50/60 Hz Terminal Load………………………………………………… 1.0 A per terminal, 1.5A maximum all terminals…

  • Emerson 1F89-0211 Heat Pump Thermostat installation and operating instruction

    Emerson 1F89-0211 Heat Pump Thermostat installation and operating instruction

    Emerson 1F89-0211 Heat Pump Thermostat APPLICATIONS THERMOSTAT APPLICATION GUIDE Thermostat Configuration Options Thermostat Applications Maximum Stages Heat/Cool Heat Pump Single Stage Compressor Single Stage Compressor Heat Pump Systems – 1 Stage Aux/Emergency Heat 2/1 SPECIFICATIONS Electrical Rating: Battery Power or Hardwire………………………… 20 to 30 VAC, 50/60 Hz Terminal Load………………………………………………… 1.5 A per terminal, 2.5A maximum…