Schneider Electric -CCT15834- programmable -thermostat- FEA

Schneider Electric CCT15834 programmable thermostat User Guide

SCHNEIDER ELECTRIC-logo

Schneider Electric CCT15834 programmable thermostatSchneider Electric -CCT15834- programmable -thermostat- PRO

Getting to know

The programmable thermostat
The THP1+ 1C thermostat is intended for time-dependent monitoring and control of the room temperature.

Displays and operating elements

  • A Display of active keys
  • B Days of the week display
  • C Time display
  • D Date display
  • E Programmed ON times
  • F Operating mode
  • G Channel Status
  • H Actual temperature
  • I Button OK
  • J Select buttons
  • K Button Menu

Schneider Electric -CCT15834- programmable -thermostat- 1

Operation

Schneider Electric -CCT15834- programmable -thermostat- 4

Menu structure

Schneider Electric -CCT15834- programmable -thermostat- 2

Initial setup

  • Select the language.
  • Confirm the message FORM DATE.
  • Select the date format.
    Set the year.
  • Set the month.
  • Set the day.
  • Confirm the message FORM TIME.
  • Select the time format.
  • Set the hours.
  • Set the minute.
  • Select summer time/winter time.

Menu Temperature

In the TEMPERATURE menu you can check the temperature (ACTUAL TEMP) and check and set the temperatures of the operation modes.

The following values are the default values for the operating modes:

  •  COMFORT: 22.0 °C
  •  REDUCED: 16.0 °C
  •  FROST: 6.0 °C

Setting a switching time

PROGRAM

A switching time is the time at which the thermostat switches to a set operating mode. You can either set switching times for a specific day of the week or copy them for multiple week days. Copied week days are referred to as a block.

To set a switching time:

  • Confirm message about free memory slots.
  • Select the operating mode.
  • Set the hour.
  • Set the minute.
  • Set the day of the week.
  • If the switching time is only to be valid for one week day, select SAVE.
  • The switching time is set.
  • If the switching time is to be copied as a block for multiple week days, select COPY.
  • If the switching time is to be copied as a block for multiple week days, select COPY.Select further days of the week and confirm in each case.
  • Week days contained in the block are indicated in the week day display.
  • To remove a week day from the block, select the week day again using the selection buttons.
  • Once the desired week days have been set, select SAVE.

Modifying a switching time

You can change the time for the switching times. In the case of switching times within a block, you can select whether the modification of the time is to apply to the whole block or only to a specific week day. This week day is then removed from the block.

  • Select the operating mode.
  • Select the switching time.
  • The display runs through all switching times in sequence. If no switching time is set for a week day, this isindicated in the display by –:–.
  • If the selected switching time is part of a block, all days of the block are shown in the week day display. Theselected week day flashes.
  • Set the hour.
  • Set the minute.
  • If the selected switching time is only set for one week day, only the option SAVE appears.
  • If the selected switching time is part of a block, select MODIFY BLOCK or MODIFY WEEK DAY.
  • MODIFY BLOCK changes the time for all switching times of the block.
  • MODIFY WEEK DAY changes the time for the selected switching time. The selected switching time is removed from the block

Deleting a switching time

You can delete switching times at any time. If a switching time is part of a block, you can delete the entire block or remove the switching time from the block. You can also delete all switching times simultaneously. Deleting a switching time:

  • Select SINGLE.
  • Select the switching time.
  • The display runs through all switching times in sequence. If no switching time is set for a week day, this is indicated in the display by –:–.
  • If the selected switching time is part of a block, all days of the block are shown in the week day display. The selected week day flashes.
  • If the selected switching time is only valid for one week day, only the option DELETE WEEK DAY appears.
  • If the selected switching time is part of a block, select DELETE BLOCK or DELETE WEEK DAY.
    • DELETE BLOCK deletes all switching times of the block.
    • DELETE WEEK DAY removes the selected switching time from the block and deletes it.

Deleting all switching times:

  • Select DELETE ALL.
  • Confirm with CONFIRM.

Setting summer time/winter time

  • You can adapt summer and winter time to your region.
  • Select summer time/winter time region.

Setting the holiday function

With the holiday function, you can set the operating mode for a longer period. The programmed switching times do not apply while the holiday function is active. You can only set one holiday time.

  • Select the operating mode.
  • Confirm BEGIN HOLIDAY.
  • Set the year.
  • Set the month.
  • Set the day.
  • Set the hour.
  • Confirm END HOLIDAY.
  • Set the year.
  • Set the month.
  • Set the day.
  • Set the hour

Setting the type of control

CONFIG

  • You can adjust the control behaviour to different types of heating.
  • NORMAL (e.g. radiator / convektor)
  • UNDERFLOOR (inertial heating systems)
  • HYSTERESIS CONTROLLER (adjustable switch on/off hysteresis)
  • AIR HEATING (fast heating systems)

Setting the wall compensation

  • You can correct variations between the detected and actual temperature (e.g. due to unfavourable installation locations) by setting up the difference:
  • Negative difference: The indicated temperature is higher than the actual temperature.
  • Positive difference: The indicated temperature is lower than the actual temperature

Setting the PIN

A PIN protects against unauthorized use. If you have forgotten your PIN, contact the Customer Care centre in your country, stating the serial number of your device.

  • Select WITH PIN.
    • NO PIN cancels the PIN protection function.
  • Confirm CURRENT PIN.
  • Set new PIN.

Setting the external input

The device has an external input, you can set whether, and in what manner, it is to respond to an external signal. In the EXT INPUT menu, you can set the function that is to be executed. If a function is activated via an external  button or switch, EXTERNAL appears in the display.

NOT ACTIVE
The external input has no function.

PERM
A preset operating mode is set permanently.

TIMER
A preset operating mode is set for a maximum of 23 hours and 59 minutes

Activating override and permanent switching
You can set override or permanent switching either via the MANUAL menu or using combinations of buttons on the device.

Override switching

  • If you wish to switch briefly to the operating mode COMFORT, activate override. This state is only valid until the next switching time.
  • If you wish to select the operating mode, use the menu MANUAL.
  • If override is active, OVERRIDE, followed by the operating mode, appears briefly in the display.

Permanent switching

  • If you wish to switch permanently to the operating mode COMFORT, activate override. While permanent switching is activated, switching times have no effect.
  • If you wish to select the operating mode, use the menu MANUAL.
  • If permanent switching is active, OVERRIDE, followed by the operating mode, appears briefly in the display.

Button combinations

Buttons  

Schneider Electric -CCT15834- programmable -thermostat- 3

Activating override Press buttons simultaneously
Activating permanent switching Press and hold buttons simultane- ously for approx. 2 s
Cancelling override

Cancelling permanent switching

Press buttons simultaneously

Resetting basic settings

  • You can reset the basic settings, such as date and time, etc., and delete or retain all switching times.
  • You have two options: You can load the factory settings via the CONFIG menu or reset the device by pressing specific combinations of buttons on the device

Loading the factory settings

  • Press LOAD FACTORY SETTINGS.
  •  Carry out the basic settings as described in the chapter “Initial setup

Resetting

  • Push all four buttons on the device simultaneously.
  • Select the language.
  • If you want to retain the switching times, select RETAIN PROGRAMS.
  • If you want to delete all switching times, select DELETE PROGRAMS.
  • Set basic settings as described in chapter “Initial setup

Programming with the memory stick

You can also transfer switching times, programs and functions to the device with the Memory stick (CCT15861). When you plug the Memory stick into the slot, you can call the following menus:

COPY KEY-$THP
Copies the switching times and settings from the Memory stick to the device.

COPY THP-$KEY
Copies the switching times and settings from the device to the Memory stick.
RUN KEY
Activates the switching times set on the Memory stick. The switching times of the device are deactivated. When
the memory element is removed, the switching times of the device are reactivated.
CHECK KEY
You can check the settings and programs on the Memory stick

Schneider Electric Industries SAS
If you have technical questions, please contact the Customer Care Centre in your country.