Salus RT510BC Electronic Room Thermostat
Product compliance
This product complies with the essential requirements and other relevant provisions of the following EU Directives: 2014/30/EU, 2014/35/EU, 2014/53/EU and 2011/65/EU. The full text of the EU Declaration of Conformity is available at the following internet address: www.saluslegal.com.
Safety Information
Use in accordance with the EU and national regulations. For indoor use only. Keep your device completely dry. This product must be installed by a competent person and in accordance with all the EU and national regulations.
Always isolate the AC Mains supply before installing or working on any components that require 230 VAC 50Hz supply.
Box content
Introduction
The programmable room thermostat RT510BC is both a programmer and a room thermostat. A programmer allows you to set ‘On’ and ‘Off’ time periods to suit your own lifestyle. A room thermostat works by sensing the air temperature, switching on the heating when the air temperature falls below the thermostat setting and switching it off once this set temperature has been reached.
So, a programmable room thermostat lets you choose what times you want the heating to be on, and what temperature it should reach while it is on.
It will allow you to select different temperatures in your home at different times of the day (and days of the week) to meet your particular needs.
Turning a programmable room thermostat to a higher setting will not make the room heat up any faster. How quickly the room heats up depends on the design of the heating system, for example, the size of boiler and radiators. Neither does the setting affect how quickly the room cools down. Turning a programmable room thermostat to a lower setting will result in the room being controlled at a lower temperature, and saves energy.
The way to set and use your programmable room thermostat is to find the lowest temperature settings that you are comfortable with at the different times you have chosen, and then leave it alone to do its job. The best way to do this is to set low temperatures first, say 18°C, and then turn them up by one degree each day until you are comfortable with the temperatures. You won’t have to adjust the thermostat further. Any adjustments above these settings will waste energy and cost you more money.
If your heating system is a boiler with radiators, there will usually be only one programmable room thermostat to control the whole house. But you can have different temperatures in individual rooms by installing thermostatic radiator valves (TRVs) on individual radiators.
If you don’t have TRVs, you should choose a temperature that is reasonable for the whole house. If you do have TRVs, you can choose a slightly higher setting to make sure that even the coldest room is comfortable, then prevent any overheating in other rooms by adjusting the TRVs.
The time on the programmer must be correct. Some types have to be adjusted in spring and autumn at the changes between Greenwich Mean Time and British Summer Time. You may be able to temporarily adjust the heating programme, for example, ‘Temporary / Permanent Override’ or ‘Boost’. All these functions are explained in the following pages of the Instructions Manual.
Programmable room thermostats need a free flow of air to sense the temperature, so they must not be covered by curtains or blocked by furniture. Nearby electric fires, televisions, wall or table lamps may prevent the thermostat from working properly.
The RT510BC from SALUS Controls is a stylish and accurate 5/2 or 24h programmable electronic thermostat with a large, easy to read Liquid Crystal Display (LCD). This programmable thermostat has been specifically designed to be used for both Volt Free and AC heating applications. This programmable thermostat can replace most common residential thermostats and is designed to be used with electric, gas or oil heating control systems.
Features
- 5/2 days or 24h programming flexibility
- Built-in start up programming for quick installation
- Volt free contacts
- Frost protection
- Large, easy to read LCD with blue backlight
- Burner on symbol
- User friendly
- Stylish casing
- Holiday Mode
- Boost function
Installation
RXBC605 Boiler Controller
Unscrew the backplate of the RXBC605 boiler controller in order to do the plug-in connections. After thatplease switch the boiler controller ON.
Button Description for RXBC605 Boiler Controller
Button | Function |
SYNC | The boiler controller will be synchronized with the thermostat. |
AUTO | The receiver will switch on and off automatically, as operated by the thermostat. |
MANUAL | Select in the event of thermostat failure to switch boiler on continuously, overriding the thermostat. |
Note: Please make sure to first wire up and turn on the receiver. After that insert the batteries into the thermostat and follow the installation steps.
RT510BC Thermostat
Insert the batteries into the thermostat. Please use 2 AA batteries.
Power up
After power up, the thermostat is reset. During system reset, all LCD icons are displayed for 2 seconds and the keys are locked. After that, all keys are unlocked and the thermostat is initialized. Then software version is shown. The typical reset display is shown below.
The following tables shows the default settings of the RT510 thermostat after Power on, or after Reset button is pressed:
Function | Status after Reset |
Operation Mode | Normal mode |
Room Temperature | 22.0°C, to be renewed within 5 seconds |
°C indicator | On |
Clock | 12:00 |
AM/PM indicator | AM |
Program | Default factory setting |
Setpoint Temperature | Default factory setting |
Program Number indicator | 1 |
SET indicator | Off |
PROG indicator | Off |
Frost Protection indicator | Off |
Heat indicator | Off |
Low-Battery Warning indicator | Off, to be renewed within 5 seconds |
Output Relay | Off |
Program | Weekday (M to F) | Weekend (SA to SU) |
1 | Time: 6:00am | Time: 8:00am |
Setpoint Temp: 21.0°C | Setpoint Temp: 21.0°C | |
2 | Time: 8:00am | Time: 10:00am |
Setpoint Temp: 14.0°C | Setpoint Temp: 19.0°C | |
3 | Time: 12:00pm | Time: 12:00pm |
Setpoint Temp: 14.0°C | Setpoint Temp: 19.0°C | |
4 | Time: 2:00pm | Time: 2:00pm |
Setpoint Temp: 14.0°C | Setpoint Temp: 19.0°C | |
5 | Time: 6:00pm | Time: 6:00pm |
Setpoint Temp: 21.0°C | Setpoint Temp: 21.0°C | |
6 | Time: 10:00pm | Time: 10:00pm |
Setpoint Temp: 14.0°C | Setpoint Temp: 14.0°C |
DIP Switch Settings
The DIP switches are found on the rear of your thermostat and can be used to change the span (temperature accuracy) of your thermostat from the default +/-0.5°C to +/-0.25°C and the programmes 5-2 or 24h. Changing the Span DIP Switch (2) may cause your boiler to operate more frequently. The DIP switches are located on the back of the thermostat.
LCD Functions
Pair the RT510BC and RXBC605
Please make sure that the thermostat and the receiver are paired. In order to do this you can use the Pairing or the testing procedure. The Testing procedure will allow you to check if the devices are communicating between them. The Pairing procedure will allow you to set up communication between them.
Pairing procedure
Note: For ending the pairing process you have two options. You can either wait for 10 min until the pairing process will automatically end or you can follow the steps below.
Testing procedure
Installer Mode
For any advanced settings please access the Installer Mode. Here you will have the possibility to adjust your frost setpoint, to set the temperature offset and also to choose from two temperature increments. Please follow the steps below in order to modify the installer parameters.
dxx | Function | Parameter | Description | Default value |
d01 | Temperature display increments | 0.1 or 0.5°C | Select temperature display increments | 0.5°C |
d02 | Temperature offset | +/-3.0°C | Calibrate your thermostat temperature | 0.0°C |
d03 | Frost setpoint | 5.0-17.0°C | Set the Frost Point temperature | 5.0°C |
Operations
The RT510BC is configured and adjusted by the use of a minimal number of user controls, and an intuitive user interface. The Backlight Liquid Crystal Display (LCD) gives a highly visible, easily readable indication of the programmable thermostat status.
Setting the time
Programming the RT510BC
You can create personalized programs for your thermostat. You have the option to choose between a 5-2 days program or a daily one by using the DIP Switches.
RT510BC | |
5-2 Days Programme | 24h Programme |
Weekdays
6 sets of time/channel Weekends 6 sets of time/channel Total: 12 settings/week |
24h
6 sets of time/channel
Total: 42 settings/week |
Repeat the steps above for programs 2-6. After you have done all the changes, please press SET to confirm all your choices and to return to the Main Screen.
Note: Don’t forget to move the DIP Switch to 24h in order to have the individual program active. After that please follow the same instructions as for the 5-2 days programme.
Functions
Review the Setpoint temperature
When no button is pressed, your thermostat is showing the actual temperature of the room. To review the setpoint (desired) temperature follow the steps below:
Temporary Override
When the temporary override is active, the setpoint temperature will be changed until the next program starts.
Note: To exit the temporary override procedure, you can wait for 3 seconds until the set temperature stops flashing or you can press on the SET button once.
Permanent Override
Note: To exit the temporary override procedure, you can wait for 3 seconds until the set temperature stops flashing or you can press on the SET button once.
Boost Function
Boost function can be activated when your thermostat is in Normal Mode, in Temporary or Permanent Override. You cannot set the Boost when in Frost or Holiday Mode. With Boost mode activated you can override, temporary override or permanently override the thermostat by setting the period of time and also by changing the Setpoint temperature.
See below the explanations for the Boost Mode settings that are available for each of the modes set on the thermostat. Please follow the one that suits you needs:
Boost Function in Normal Mode
Note: RT510BC will work in Boost Mode for up to 9 hours, set on the desired temperature. After the Boost time is over, the thermostat will return to Normal Mode and will follow the schedule created by you.
Boost Function in Permanent Override Mode
Note: RT510BC will work in Boost Mode for up to 9 hours, set on the desired temperature. After the Boost time is over, the thermostat will return to the Permanent Override Mode.
Boost Function in Temporary Override Mode
Note: RT510BC will work in Boost Mode for up to 9 hours, set on the desired temperature. After the Boost time is over, the thermostat will return to Normal Mode, following the schedule set by you.
Boost Function in Frost/Holiday Mode
Note: When Frost/Holiday Mode are activated, the Boost function will be canceled. Also, you cannot activate the Boost function when the thermostat is set in Frost or Holiday Mode.
Frost Function
Frost function allows you to turn the Frost protection ON or OFF. The frost setpoint temperature is preset at 5°C. You can change the frost setpoint temperature by modifying the Installer Mode parameters, d03. If the room temperature is lower than the Frost setpoint then the thermostat will automatically change to Frost mode ON. Follow the steps below for setting up the Frost Mode.
Holiday Function
Holiday function will turn off the relay, blocking your thermostat from sending any call for heat. If room temperature is lower than the frost setpoint, then Frost Mode will be activated.
Follow the steps below in order to set the Holiday Mode.
Other Functions
Backlight
The backlight of the RT510BC is switched on automatically whenever any of the keys are pressed. The backlight will remain illuminated for approximately 5 seconds after the last key press, except if you are changing settings within the Clock, Programme or Temporary Override modes. In this case, the backlight will remain illuminated throughout the setting change process. The backlight will not illuminate if the RT510BC battery is low.
Battery Status
The RT510BC checks the battery voltage frequently during normal operation. If the battery voltage is sensed as being low (this is normally when the battery voltage falls to a level of around 2.6V), the low battery indicator will be displayed on the screen. You should replace the batteries as soon as possible to prevent any possible operating problems. When you want to change the batteries your device will use the internal memory to backup your settings. You have 30 sec to change the batteries before losing your settings.
Sleep Mode
By pressing both the UP and DOWN keys together, the RT510BC will enter SLEEP mode. In this mode, all the RT510BC functions will be paused to save battery power, with the exception of the clock which will continue to run in the background.
While in SLEEP mode:
- The LCD display will be blank.
- All output from the Control Unit will be turned off immediately. Press any key to wake up the RT510BC and cancel SLEEP mode.
Reset Function
The Reset Button is provided as a way to restore the programmable thermostat to its default factory settings. Pressing this button will delete any previously entered settings. This should only be done by your installer.
Technical Information
Model | RT510BC |
Type | Electronic programmable thermostat, designed for Volt Free and AC
heating applications |
Programming Modes | User selectable for 5/2 and Individual day options |
Program Number | 1-6 Selectable |
Modes | Holiday, Boost, Program and Frost |
Override | Permanent and temporary |
Frost Protection | 5ºC Adjustable (5-17°C) |
Power Source | 230V AC 50Hz for RXRT510 and 2xAA batteries for RT510BC |
Temperature Scale | 5 to 35ºC |
Device Parameters
Operating Temperature |
See page 9
0 to 40ºC |
Storage Temperature | -20 to 60ºC |
Warranty
SALUS Controls warrants that this product will be free from any defect in materials or workmanship, and shall perform in accordance with its specification, for a period of two years from the date of installation. SALUS Controls sole liability for breach of this warranty will be (at its option) to repair or replace the defective product.
- Customer Name: ……………………………………………
- Customer Address: …………………………………………
- Post Code: ……………………………………………………..
- Tel No: ………………………………………………………….
- Email: ……………………………………………………………
- Company Name: …………………………………………….
- Tel No: …………………………………………………………
- Email: …………………………………………………………..
- Installation Date: …………………………………………..
- Installer Name: ……………………………………………..
- Installer Signature: ……………………………………..
SALUS Controls PLC
SALUS House
Dodworth Business Park South, Whinby Road, Dodworth, Barnsley S75 3SP, UK.
Sales:
- T: +44 (0) 1226 323961
- E: s[email protected]
Technical:
- T: +44 (0) 1226 323961
- E: [email protected]
- www.salus-controls.com
SALUS Controls is a member of the Computime Group
Maintaining a policy of continuous product development, SALUS Controls plc reserves the right to change specifications, design, and materials of products listed in this brochure without prior notice.
For the latest PFD Instruction Manual, go to www.salus-manuals.com
References:
Download Manual
Salus RT510BC Electronic Room Thermostat Installation Guide
OTHER MANUAL
Salus RT510BC Electronic Room Thermostat Quick Guide
Salus RT510BC Electronic Room Thermostat Specification Sheet
Leave a Reply