SALUS IT500 Internet thermostat
Introduction
The iT500 controls your heating and hot water from anywhere via your smartphone or laptop. Your pc and laptop connects to the system using existing broadband connection. The system is wireless so it’s easy to instal.
FEATURES:
- Access and control your heating and hot water via the internet
- Compatible with your PC or smartphone – they connect to the system using your existing broadband connection
- Touch sensor panel
- The internal system uses 868 MHz for robust communication
- 3 system configurations:
- One central heating zone only
- Two central heating zones (optional iT300 remote sensor required for second zone)
- One central heating zone plus hot water
- ECO & HOLIDAY mode
- Free iT500 Plus app to download
Box contains:
- iT500TR thermostat
- iT500RX receiver (a wireless receiver that will connect to your boiler.
- It is suitable for combination and system boiler).
- iTG500 Internet gateway – connects via a short cable to your broadband internet router.
The gateway enables internet access and control of your system.
Product compliance
This product complies with the following EU Directives: Electromagnetic Compatibility 2014/30/EU, Low Voltage Directive 2014/35/EU, Directive 2014/53/EU and 2011/65/EU. Full information is available on the website www.saluslegal.com
Safety information
Use in accordance with national and EU regulations. Use the device only as intended, keeping it in a dry condition. The product is for indoor use only. Installation must be carried out by a qualified person in accordance with national and EU regulations.
Technical specification
- Supply:
- iT500 – 2 x AA Batteries
- iT300 – 2 x AAA Batteries
- iT500RX – 230 V AC 50Hz
- Rating Max:
- CH1: 16 A resistive, 5 A inductive
- CH2: 5 A resistive, 3 A inductive
- Temperature range: 5°C – 35°C (in step 0,5°C)
- Frost protection temperature: 5°C – 9°C (in step 0,5°C)
- Hysteresis: 1°C
- Storage temperature: -20°C to 60°C
- Protection degree IP: IP 30
Connecting the gateway to your existing router
Inserting the batteries in the iT500 Thermostat
- Remove the battery cover from the base of the iT500 Thermostat.
- Make a note of the serial number printed inside the base of the iT500 Thermostat.
- With the unit face down, insert the first battery supplied into the right hand side of the base of the iT500 Thermostat.
Note: You can make a note of your STA number here for future reference: - Insert the second battery supplied into the left hand side of the base of the iT500 Thermostat.
- Ensure the batteries are fitted securely in the base of the iT500 Thermostat.
- Replace the battery cover to the base of the iT500 Thermostat.
iT500 Plus application
Download the iT500 Plus app, create an account and register your device. Follow the on screen instructions to complete all the steps.
Features available only on the App:
- HOLIDAY mode
- Antifrost temperature changing
- Energy saving mode (set the lowest schedule temp.)
- Simplified schedule setup
Note: You can add a few iT500 thermostat to one account.
LCD icon description
- Settings indicator
- Internet indicator
- RF signal indicator
- Low battery status
- Holiday indicator
- Button lock indicator
- Temperature unit
- Temperature indicator
- Hot water heating in continuous mode
- Hot water override
- Automatic mode
- Antifrost mode
- Hot water heating
- Hot water indicator
- Cooling mode indicator (zone 2)
- Zone 2 indicator
- Heat mode indicator (zone 2)
- Cooling mode indicator (zone 1)
- Zone 1 indicator
- Heat mode indicator (zone 1)
- Program number indicator
- Clock display
- Day of the week
Installation of wall bracket docking (optional)
For best results mount iT500 1.5m from ground level.
- Attach the wall mounting bracket to a suitable wall using the fittings supplied and the built in level.
- After first ensuring that the bracket is secure, clip the iT500 into place by aligning the recess on the back of the unit to the bracket and clipping into place.
- Once clipped into place, ensure the unit is securely seated on the bracket.
Desk mount option iT500
For the desk mounted option, simply clip the clear stand supplied separately into the back of the unit.
iT500RX receiver switch functions
- AUTO – receiver operate in automatic mode (works according to thermostat or app)
- MANUAL – receiver operate according to the switch located below
- OFF – receiver is disabled
- CH – in manual mode, zone 1 are turned ON
- AUX – in manual mode, zone 2 are turned ON
- CH/AUX – in manual mode, zone 1 and zone 2 (or HW) are turned ON
iT500RX terminals description
Terminal name | Function | |
L,N | 230V AC power supply | |
CH (zone 1) |
NC | Normally closed terminal |
NO | Normally open terminal | |
COM | Common Terminal | |
AUX (zone 2)
or |
NC | Normally closed terminal |
NO | Normally open terminal | |
COM | Common Terminal |
Wiring diagrams for single heating zone
Wiring diagram for 2 heating zones +
Installation of iT500RX receiver
Note: Always shut off the AC mains supply before installing or working on any components.
- Loosen the screws at the bottom of the receiver unit and unclip the
- Fit the back of the receiver unit to the wall using the fittings supplied. Then wire up the receiver using proper diagram.
- Clip the front of the unit back and securely screw the front of the receiver in place
Fitting the wall bracket and mounting the iT300
Note: iT300 purchased separately. Can only be used if your system supports second central heating zone
- Insert the 2x AAA batteries supplied in the battery case under the cover on the back of iT300 unit.
- Attach the wall mounting bracket to a suitable wall using the fittings supplied.
- Align the grooves on the back of the iT300 unit and slide onto the bracket.
Setting up the iT500 thermostat
After powering up iT500 for the first time the display will go through the following sequence.
Pairing iT500 with iT500RX receiver
- Using a paper clip, insert into the hole marked SYNC at the bottom of iT500RX receiver.
- The bottom switch will show a constant red light when iT500RX receiver is ready to pair. Now go to iT500 thermostat.
- Press the power button to highlight the display.
- Press and holdand buttons for 3 sec.
- Press button to launch pairing process.
- Pairing process can take up to 10 minutes.
- When iT500RX receiver and iT500 thermostat are paired then the light will be green. Press to return to the home screen.
FAILSAFE MODE: In the event of RF signal loss, your system will be switched on for 4 minutes, then off for 11 minutes. If you want to disable FAILSAFE MODE when RF link has been lost then move the slide switch on iT500RX to either the Manual or Off position.
Pairing the iT300 to the thermostat
Note: iT300 purchased separately. Can only be used if your system supports second central heating zone.
- To pair iT300 to the receiver, insert a paperclip or similar object into the hole on the left hand side of iT300 for 2 seconds.
- A red light will flash in the top right hand corner of the iT300.
- Press the power button to highlight the display.
- Press and hold and buttons for 3 sec.
- Press button to launch pairing process.
- Pairing process can take up to 10 minutes.
- iT500 has successfully paired with iT300 when the antenna stops flashing. Press to return to the home screen.
Note: Please note the red LED on the iT300 will continue to flash and eventually timeout.
Selecting your system configuration
This menu should only be entered by the installer as changes can have a detrimental effect on your heating system.
At any time press for return to the previous step or hold for 5 seconds to return to the home screen.
The countries marked with * do not observe Daylight Saving Time. For details please see below.
DST (Daylight Saving Time) ON will automatically change your time from summer to winter.
Setting the time and date
When connected to the internet, the iT500 will set time and date automatically. However this can also be set manually.
Operating modes
Setting the temperature
Note: If you set the temperature in AUTO mode (temporary override) the setpoint temperature won’t be changed until the next program starts.
Lock Function
To enable or disable lock function press and hold buttons together.
Program schedule for heating zone
You can easily set your schedule via iT500 Plus app . If you want to set schedules directly by the iT500 thermostat, please follow the instruction below.
In iT500 thermostat you can define 6 schedule programs per day. You can set different temperature level for each program. While programming specific time interval you must be aware that you are about to set at what time the program will start. For example, if you set program 1 for 6:00 (AM) it means the program is going to run at 6:00 (AM) and will running till the time set for next program. Example of 4 temperature levels for 6 schedule programs:
Note: When you set program schedule, necessarily set all 6 programs. I.e. if you want to set 2 temperature levels, you need to set first temperature level for 1 to 5 program and set second temperature level only for program 6.
Program schedule for hot water system
Note: In the program schedule for the hot water system (HW) you can set 3 scheduled programs per day. For each HW program, you must define the time of start and the time of the end.
REFERENCE
Download Manual:
SALUS IT500 Internet thermostat Quick Guide
OTHER MANUALS
SALUS IT500 Internet thermostat User Manual
Leave a Reply