  • On replacement installations, mount the new thermostat in place of the old one if possible.
  • Locate the thermostat on an inside wall, about 5 ft. (1.5m) above the floor, and in a room that is used often.
  • Do not install it where there are unusual heating conditions, such as: in direct sunlight; near a lamp, radio, television, radiator register, or fireplace; near hot water pipes in a wall; near a stove on the other side of a wall
  • Do not locate in unusual cooling conditions, such as: on a wall separating an unheated room; or in a draft from a stairwell, door, or window.
  • On new Installations, follow the guidelines listed below.
  • Do not locate in a damp area. This can lead to corrosion that will shorten thermostat life.
  • Do not locate where air circulation is poor, such as: in a corner or an alcove; or behind an open door.
  • Do not install the unit until all construction work and painting has been completed.
  • This thermostat does not require levelingRitetemp -6010 -non-programmable -Thermostat - 1

Label Wires to Old Unit

  • Switch electricity to the furnace and air conditioner OFF; then proceed with the following steps.
  • Remove cover from old thermostat. Most are snap-on types and simply pull off. Some have locking screws on the side or front. These must be loosened.
  • Note the letters printed near the terminals.
  •  Carefully attach labels (enclosed) to each wire. Label the wires one at a time. You must have all the wires labeled before you proceed.

Remove old unit

  • Remove the wires from the terminals of the old thermostat.
  • Make sure the wires do not fall back inside the wall.
  • Wind them around a pencil to keep them from falling.
  • Remove the old thermostat from the wall. Fill wall opening with fiber glass insulation to prevent draftsRitetemp -6010 -non-programmable -Thermostat - 2

Mount the 6010

  •  Separate front from back of unit. Grasp the front of the unit and the back of the unit and pull apart. The thermostat body away from the base.Ritetemp -6010 -non-programmable -Thermostat - 3
  •  Hold the base against the wall, with the wires coming through the opening below the terminal block.
  • Position the base for best appearance
  •  Attach the base to the wall with the two screws provided.
  • If you are mounting the base to sheet rock or if you are using the old mounting holes, use the plastic anchors provided.
  • Drill a 3/16-in.(4.8mm) hole for the insert at each screw location, then mount the base.Ritetemp -6010 -non-programmable -Thermostat - 4

Gas-Electric Selection

  • If you have Electric Heat or a Heat Pump you must place the Gas/Electric jumper in the ELECT position (thermostat controls the Fan).
  • If you have Gas Heat the Gas/Electric Jumper should be in the GAS position (furnace controls the Fan ).Ritetemp -6010 -non-programmable -Thermostat - 5

Install Batteries

  • The 6010 requires batteries to operate your system. Switch MODE switch to OFF and the FAN switch to AUTO.
  • Insert 2 AA alkaline batteries according to the polarity noted in the compartment.Ritetemp -6010 -non-programmable -Thermostat - 6

NOTE: Replace the batteries once a year or when this low battery indicator appears on the right side of the unit

Power Options

  • The 6010 can run on batteries only. (2AA Alkaline)
  • The batteries will last well over 1 year. If the batteries are not replaced the thermostat will stop working.
  • The 6010 can run on the C wire if available.
  • As shown in the wiring diagrams, The C wire is the other side of the 24VAC heating transformer. If the C wire is used, the batteries are not needed.

Wire Connections

Make sure your wires are labeled. This is necessary to determine which step-by-step wiring diagram you should use. This may require you to find the ‘other end’ connection for each wire on your heating or air conditioning equipment and read the label there. If you have a Zoned Heating/Cooling system with multiple thermostats, please refer to our website at www.ritetemp-thermostats.com for installation notes or call 1-877-505-2353

Before you Connect Wires

  • Please refer back to these guidelines for safe and secure wire connections.
  •  Take care not to damage the labels for each wire in handling.
  •  Strip insulation 3/8 in. (9.5mm) from wire ends.
  •  Connect labeled wires only to a terminal with corresponding letter.
  •  Bend the wire slightly, insert the wire under the contact plate and tighten the screw down onto the wire.Ritetemp -6010 -non-programmable -Thermostat - 7

WIRE LABEL LIST

  • R – Single source power for heat/cool (R connected to
  • RC and RH using the jumper wire)
  • RH or R – Heating Power
  • RC – Cooling Power
  • W – Heating return
  • G – Fan return
  • Y – Compressor return
  • H – Humidifier (built into the furnace)
  • W2 – 2nd stage heat in NORMAL, auxiliary heat in PUMP mode.
  • A – For 3 wire zoned heating systems
  • C – AC power for the thermostat if available
  • O – Damper control (Zoned heating) or heat pump changeover valve (powered in COOL)
  • B – Damper control (Zoned heating) or heat pump changeover valve (powered in HEAT) NOTE: Do not connect both O and B on a heat pump. Connect O to O & tape off B.
  • X – Tape off X
  • E – Tape off E

What Wires Do You Have?
The Wire Label List shows wire labels used on Ritetemp thermostats. Please determine what wires you have and select the correct wiring diagram to “go to” on pages 8-9. If you have a HEAT PUMP select a wiring diagram on pg 9.Ritetemp -6010 -non-programmable -Thermostat - 8 Ritetemp -6010 -non-programmable -Thermostat - 9

Wire Connections
When you have finished connecting the wires attach control unit to wall unit. Hook the top of the body onto the base, swing the body down, and snap the body onto the base.Ritetemp -6010 -non-programmable -Thermostat - 10

Check Unit

To check Fan: (If you connected the G wire)

  •  Switch Mode to OFF during fan test.
  •  Switch the FAN switch to the ON position. Verify air is blowing from vents.
  •  After test, return to Fan switch to AUTO, and Mode to HEAT or COOL

To check HEAT mode:

  • Set the mode switch to HEAT. Set the fan switch AUTO.
  •  Adjust the temperature control to raise the target temp to 90o.
  •  Wait 5 min.
  •  Verify that heat is blowing from the system.Ritetemp -6010 -non-programmable -Thermostat - 11

To check COOL mode:

  •  Set the mode switch to COOL.
  •  Adjust the temperature control to 5o below the room temperature.
  • Wait 5 min.
  •  Verify that cool air is blowing from the system.

Congratulations, you have successfully installed your unit. Please proceed to the OPERATING Guide to initialize the new thermostat. REMEMBER, Mode Switch must be in HEAT or COOL to operate.

2 WIRE Heating (GAS MILLIVOLT or 24vac

  • STEP 1 – Connect the R (or RH) wire to the RH terminal on the thermostat. This connects the HeaterRitetemp -6010 -non-programmable -Thermostat - 12
  • Power to the thermostat.
  • STEP 2 – Connect the W wire to the W terminal on the thermostat.
  • This connects the heater control line to the thermostat.Ritetemp -6010 -non-programmable -Thermostat - 13

3 WIRE

  • STEP 1 – Connect the R (or RH) wire to the RH terminal on the thermostat. This connects to the Heater Power .Ritetemp -6010 -non-programmable -Thermostat - 16
  • STEP 2 – Connect the W wire to the W terminal on the thermostat. This connects the heater control line to the thermostat.
  • STEP 3 – Connect the G wire to the G terminal on the thermostat. This connects the Fan to the thermostat.

Ritetemp -6010 -non-programmable -Thermostat - 15

4 WIRE NON_HEAT PUMP

  • STEP 1 – Connect the Y wire to the Y terminal on the thermostat. This connects to the Cooler compressor.Ritetemp -6010 -non-programmable -Thermostat - 18
  • STEP 2 – Connect the RH or R wire to the RH terminal on the thermostat. This connects the Heater/Cooler Power.
  • STEP 3 – Connect the W wire to the W terminal on the thermostat. This connects to the heater control line.
  • STEP 4 – Connect the G wire to the G terminal on the Thermostat. This connects to the Fan.Ritetemp -6010 -non-programmable -Thermostat - 17

Your HVAC system is now connected to the thermostat

5 WIRE NON_HEAT PUMP

  • STEP 1 – Remove the Jumper wire.
  • STEP 2 – Connect the Y wire to the Y terminal on the thermostat. This connects to the Cooler compressor.Ritetemp -6010 -non-programmable -Thermostat - 18
  • STEP 3 – Connect the RH wire to the RH terminal on the thermostat. This connects to the Heater Power .
  • STEP 4 – Connect the RC wire to the RC terminal on the thermostat. This connects to the Cooling Power .
  • STEP 5 – Connect the W wire to the W terminal on the thermostat. This connects to the heater control line.
  • STEP 6 – Connect the G wire to the G terminal on the Thermostat. This connects to the Fan.Ritetemp -6010 -non-programmable -Thermostat - 19

Your HVAC system is now connected to the thermostat.

NORMAL 2 Stage  Heat System

  • STEP 1 – Connect the G wire to the G terminal on the thermostat. This connects the Fan.Ritetemp -6010 -non-programmable -Thermostat - 20
  • STEP 2 – Connect the between W wire to W. This connects the 1st stage heat.
  • STEP 3 – Connect the between W2 wire to W2. This connects the 2nd stage heat.
  • STEP 4 – Connect the R wire to the RH terminal on the Thermostat. This connects to the 24vac power.Ritetemp -6010 -non-programmable -Thermostat - 21

Your HVAC system is now connected to the thermostat. (If the system also has AC, connect it per instructions for RC and Y on pg 14)

HEAT PUMP w/o Auxiliary Heat

  • STEP 1 – Connect the G wire to the G terminal on the thermostat. This connects the Fan.Ritetemp -6010 -non-programmable -Thermostat - 22
  • STEP 2 – Add a jumper wire between W and Y.
  • STEP 3 – Connect the Y wire to the Y terminal on the thermostat. This connects the Compressor.
  • STEP 4 – Connect the O or B wire to the O or B terminal on the thermostat. (If you have both O and B contact Ritetemp or your local HVAC contractor for further help) This connects the change over valve.
  • STEP 5 – Connect the R wire to the RC terminal on the Thermostat. This connects to the 24vac power.Ritetemp -6010 -non-programmable -Thermostat - 23

Your HVAC system is now connected to the thermostat.

HEAT PUMP with Auxiliary Heat

  • STEP 1 – Connect the G wire to the G terminal on the thermostat. This connects the Fan.Ritetemp -6010 -non-programmable -Thermostat - 24
  • STEP 2 – Add a jumper wire between W and Y.
  • STEP 3 – Connect the Y wire to the Y terminal on the thermostat. This connects the Compressor.
  • STEP 4 – Connect the O or B wire to the O or B terminal on the thermostat. (If you have both O and B wires, use the O and tape off the B).
  • This connects the change over valve.
  • STEP 5 – Connect the R wire to the RC terminal on the Thermostat. This connects to the 24vac power.
  • STEP 6 – Connect W or W2 to W2 on the thermostat. This connects the AUX heat.Ritetemp -6010 -non-programmable -Thermostat - 25

6010 Features

The 6010 can be used with most 24 volt gas, oil or electric heating and air conditioning systems, heat pump systems with or without auxiliary heat, Normal 2 Stage systems, Zoned Hot-Water, Zoned Forced air systems, or gas millivolt heating systems. It cannot be used with 120 volt heating systems or. Ask The Home Depot for other thermostats to control those systems. The 6010 is digital. You can program your desired Heat and cool temperature by setting the dial. The unit uses no harmful mercury. A 5-minute minimum off time in COOL protects your air conditioning system from being damaged. Two “AA” batteries (not included) are used to run the thermostat in some installation. “C” wire installations can make batteries last many times longer.Ritetemp -6010 -non-programmable -Thermostat - 26

Ritetemp

REFERENCE

DOWNLOAD MANUAL

Ritetemp 6010 non-programmable Thermostat Installation Guide

OTHER MANUALS:

Ritetemp 6010 non-programmable Thermostat Operational Manual

Ritetemp-LOGO

Ritetemp 6010 non-programmable Thermostat Installation Guide


Posted

in

by

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *