Warmup-Tempo-Digital-Programmable-Thermostat-Installation-Guide-FEATURED

Warmup Tempo Digital Programmable Thermostat Operating Guide

Warmup-logo - Copy

Warmup Tempo Digital Programmable Thermostat 

Warmup-Tempo-Digital-Programmable-Thermostat-Installation-Guide-PRODUCT

Introduction

The Tempo has been designed with simplicity in mind and is highly intuitive in its programming. The sliders and simple rotary control make setting of the thermostat quick and easy.

Warmup-Tempo- Digital-Programmable- Thermostat -Operating -Guide-FIG-1

  1.  Rotary Control (Turn clockwise to increase and anti-clockwise to decrease.)
  2. Main Button
  3. Program Slide control (only used during programming)
  4. Mode Slide control
  5. Reset Button
  6.  Replaceable CR2032 batteryWarmup-Tempo- Digital-Programmable- Thermostat -Operating -Guide-FIG-2
 

1.

 

Normally shows the current temperature in the room. This can be either the floor temperature or the air temperature. (See icon 4).

When you are setting a program or manual temperature this icon will Temporarily show the set temperature.

 

2.

 

During programmed operation, this thermometer will show whether the thermostat is at “Comfort” Warmup-Tempo-Digital-Programmable-Thermostat-Installation-Guide-FIG-5or “Setback”Warmup-Tempo-Digital-Programmable-Thermostat-Installation-Guide-FIG-6 temperature. The icon Warmup-Tempo-Digital-Programmable-Thermostat-Installation-Guide-FIG-7will be displayed when “Comfort -1/ -2 is the target temperature. (Only used with the Fil Pilote)

3.  

This Warmup-Tempo-Digital-Programmable-Thermostat-Installation-Guide-FIG-8icon is displayed when the heating is on.

4. These icons show the type of temperature regulation being used. FloorWarmup-Tempo-Digital-Programmable-Thermostat-Installation-Guide-FIG-9 Sensor Air SensorWarmup-Tempo-Digital-Programmable-Thermostat-Installation-Guide-FIG-10

Regulator (This mode should only be used in special situations, please contact Warmup for additional information).

5. These icons show the mode in which your thermostat is being used:

 

Program mode will run the scheduled program

Warmup-Tempo-Digital-Programmable-Thermostat-Installation-Guide-FIG-11Manual mode will hold a fixed temperature

Frost Protection will not allow the temperature to fall below 5°C      Standby mode

NOTE: When the thermostat displays both the manual and comfort icon the thermostat is in a manual override and will

hold a fixed temperature until the next scheduled program period.

6. These icons show which time of day is being programmed.

 

Warmup-Tempo- Digital-Programmable- Thermostat -Operating -Guide-FIG-6

 

Morning                                      Day                                             Evening                                              Night

7. This area shows the current time and day of the week.
8. These are error icons (see troubleshooting section) or special command icons:

 

Floor sensor error Overheat limit has been reached  Warmup-Tempo- Digital-Programmable- Thermostat -Operating -Guide-FIG-7There is no mains power

Battery is low

Getting started
In order to program the Tempo thermostat all you need to do is slide the Program Slide control from the top position to the bottom position, customizing the program along the way.
If you make a mistake, return the Program Slide control to the previous position and start again. In order to change a setting value, turn the Rotary Control. Pressing the Main Button will accept the value and move you on to the next value that needs setting. The Tempo thermostat has a number of “Installer Settings”. If your thermostat has been installed correctly and is working then it is unlikely that you will need to change these again. For additional details see “Installer settings” section. Your thermostat can be set so that the programming is done for “all days the same”, “weekday and weekend” or “7 day”. To change this setting, see the “set time/day” section.

Programming the thermostat

To program your thermostat all you need to do is move the Program Slide control on the right-hand side of your thermostat from top to bottom. The table below will explain what you can do at each step.

Set Time /Day Warmup-Tempo-Digital-Programmable-Thermostat-Installation-Guide-FIG-14 Turn the Rotary Control to change the current clock time. Once the clock time has been set, press the Main Button, you will now be able to set the day of  the week. Turn the Rotary Control to select the correct day.

 

Your thermostat will by default allow you to set a weekday and weekend program (5-2d). If you would like to set “all days the same” (1d) or “7 day” programs (7d) then hold the Main Button for 5 seconds whilst in the set time/ day slide position. Once in this mode, turning the Rotary Control will allow   you change this setting. Push the Main Button or move the Program Slide to accept the value.

 

Once you have set the time and day, move the Program Slide to the next position to accept the value.

SET TIMING Warmup-Tempo-Digital-Programmable-Thermostat-Installation-Guide-FIG-15 When in any of these positions you can set the start time for “morning” (1), ”day” (2), ”evening” (3) and “night “ (4) periods.

The “morning” and “evening” periods will follow the comfort temperature, “day” and “night” periods will follow the setback temperature.

 

Using the Rotary Control, select the start time and press the Main Button to move to the next day.

 

If you hold the Main Button for 3 seconds it will copy the start time to the next day.

 

Tip – If you want to set the thermostat so that it is keeping the comfort temperature all day and only setback at night, then just set the “day” start time equal to the “evening” start time.

 

Set Temperatures

 

Warmup-Tempo-Digital-Programmable-Thermostat-Installation-Guide-FIG-16

 

Here you can set the temperature which will be used for the comfort and setback temperatures.

Done Warmup-Tempo-Digital-Programmable-Thermostat-Installation-Guide-FIG-17 Move the Program Slide control to the lowest position in order to start your thermostat. Heating will not occur if the Program Slide control is not in this position.

Selecting your mode
Your thermostat can be set to run a program, hold a fixed temperature, and efficiently protect your home from freezing or standby. You can select these modes by moving the Mode Slide control on the bottom of your thermostat

Standby Warmup-Tempo-Digital-Programmable-Thermostat-Installation-Guide-FIG-18 The thermostat will not come  on.

 

NOTE: The thermostat is still connected to the mains electricity supply and your heating system is not isolated. Always isolate from the mains before undertaking any maintenance.

Frost Protection Warmup-Tempo-Digital-Programmable-Thermostat-Installation-Guide-FIG-19

 

 

The thermostat will not let the temperature fall below 41°F (5°C).

Manual Warmup-Tempo-Digital-Programmable-Thermostat-Installation-Guide-FIG-20  

The thermostat will hold a fixed temperature. Just turn the Rotary Control to change the temperature.

Auto Warmup-Tempo-Digital-Programmable-Thermostat-Installation-Guide-FIG-21 In this position your thermostat will run the program you have set.     If you would like to Temporarily adjust the temperature, just turn the

Rotary Control. At the start of the next heating period, your thermostat will automatically resume your programming schedule.

Installer settings

These are settings that should be set by the installer of the thermostat and are unlikely to need to be changed again during the product’s life. To enter the installer setting mode, remove the thermostat from the wall plate. Press and hold the Main Button and, using a pointed device, press and release the Reset Button on the back of the thermostat. After 5 seconds release the Main Button on the front of the thermostat.
Once in the installer setting mode, you can turn the Rotary Control to change your selection and press the Main Button to accept your setting and proceed to the next step. Once you have completed all the steps you will automatically exit the installer setting mode.

Installer Step Setting Configured Default Value LCD Example
1. Change clock format (12hr/24hr) “12” Warmup-Tempo- Digital-Programmable- Thermostat -Operating -Guide-FIG-7
2. Change unit of measurement (Degree C/F) °F
3. Change sensor used to target temperature (Floor/ Air/ Regulator)

 

Note: In regulator mode the thermostat will run for a set number of minutes in a 10 minute cycle.

Floor Warmup-Tempo- Digital-Programmable- Thermostat -Operating -Guide-FIG-8
4. Set Floor Sensor Type

 

If you already have a sensor installed a sensor for a different model thermostat you can use this setting to change the sensor value and allow the thermostat to function. The possible options are NTC 10K (probe supplied with the Tempo) NTC 12K (probe supplied by Warmup with previous models of thermostat).

Note: Warmup can only validate the thermostats performance when used with  a Warmup probe supplied with the Tempo.

10K Warmup-Tempo- Digital-Programmable- Thermostat -Operating -Guide-FIG-9
5. Decide whether the thermostat uses Adaptive Learning to pre heat the room for your schedule. On Warmup-Tempo- Digital-Programmable- Thermostat -Operating -Guide-FIG-10
6. Set Overheat limit to protect your

floor.

 

Please note, the Tempo will only allow you to set a temperature 2°C/4°F lower than the Overheat limit

30°F  

Warmup-Tempo- Digital-Programmable- Thermostat -Operating -Guide-FIG-12

7. Set an offset value to calibrate the temperature reading of your thermostat sensors 0°F  

Warmup-Tempo- Digital-Programmable- Thermostat -Operating -Guide-FIG-13

  Error messages / Troubleshooting

The thermostat is not controlling the temperature Ensure that the Program Slide is in the run position (lowest point) and that the Mode Slide control (bottom) is in the manual or program positions.
Floor sensor error If you see the floor sensor error icon Warmup-Tempo-Digital-Programmable-Thermostat-Installation-Guide-FIG-28or “ – – “ on the screen it means that your thermostat has been unable to detect the temperature of the floor. Please contact Warmup.
Overheat If you see the Warmup-Tempo-Digital-Programmable-Thermostat-Installation-Guide-FIG-29overheat this means that your floor has become too hot and the heating has been suspended. Please contact Warmup.
Low battery The low battery icon Warmup-Tempo-Digital-Programmable-Thermostat-Installation-Guide-FIG-30will display when the battery needs to be replaced. The thermostat must be connected to the mains electricity supply in order to work, it is not designed to be used with an intermittent power supply.  If the battery is not installed then your thermostat will not be able to maintain the clock time if power is lost.
Heating starts too early If your heating is coming on too early, then this may be because the Adaptive Learning function is turned on. This function allows your thermostat to learn how long it will take to heat up to ensure it is the correct temperature at the start of the comfort periods.

See the “installer settings” section of this guide.

Incorrect calibration Your thermostat should not need any calibration, however, if you would like to apply an

offset to the temperature settings see the “installer settings” section.

No mains electricity If you see the no mains power icon Warmup-Tempo-Digital-Programmable-Thermostat-Installation-Guide-FIG-31this means that the thermostat is not receiving power.  Check that the thermostat logic module is properly installed on the power module and that the mains electricity supply is connected.
Regulator mode (Reg) is displayed In this mode your thermostat will come on for a set number of minutes in a 10 minute cycle. The thermostat will not use the temperature for control. Please contact Warmup for additional details.
HI or LO is displayed The thermostat will display “HI” if the ambient temperature exceeds 122°F (50°C) and “LO” when the ambient temperature falls below 32°F (0°C).

Warranty

Warmup Inc warrants this product, to be free from defects in the workmanship or materials, under normal use and service, for a period of three (3) years from the date of purchase by the consumer. If at any time during the warranty period, the product is determined to be defective, Warmup shall repair or replace it, at Warmup’s option.If the product is defective, please either,

  1. return it, with a bill of sale or other dated proof of purchase, to the place from which you purchased it, or
  2. contact Warmup. Warmup will determine whether the product should be returned, or replaced.

This warranty does not cover removal or reinstallation costs, and shall not apply if it is shown by Warmup that the defect or malfunction was caused by damage that occurred while the product was in the possession of a consumer. Warmup’s sole responsibility shall be to repair or replace the product within the terms stated above. WARMUP SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. THIS WARRANTY IS THE ONLY EXPRESS WARRANTY WARMUP MADE ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE THREE-YEAR DURATION OF THIS WARRANTY. This warranty does not affect your statutory rights.
PLEASE REGISTER YOUR WARMUP PRODUCT AT: www.warmup.com (USA) or www.warmup.ca (CANADA)

Customer care
For any questions regarding product installation or operation, please contact Warmup at:

Warmup Inc
52 Federal Road
Unit 1F
Danbury, CT 06810

USA
T: 888-927-6333
F: 888-927-4721
[email protected] www.warmup.com

Canada
T: 888-5-WARMUP (92-7687)
F: +1-888-927-4721 [email protected] www.warmup.ca

REFERENCE

Download Manual

Warmup Tempo Digital Programmable Thermostat Operating Guide

OTHER MANUALS

Warmup Tempo Digital Programmable Thermostat Installation Guide

Warmup Tempo Digital Programmable Thermostat Product Specifications

Warmup-logo - Copy

Warmup Tempo Digital Programmable Thermostat Operating Guide

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *