Warmup OCC2 Thermostat
Introduction
Getting started
Buttons
A:![]() |
B: | C: | D:![]() |
Pin button adjust of clock | On/off | Reset to factory setting | Adjustment down |
E: | F: | G: |
OK –
accept |
Adjustment up | Display |
Display symbols
H: | I: | J: | K: |
Clock function | Manual mode | Time and temperature | Day number |
L: | M: | N: |
Heating on | %
Monitoring of switch-on time |
4-event symbol
|
Setting the thermostat into operation
The first time power is connected the clock and day will be flashing and must be set. If you need to adjust the time of the thermostat at a later date, insert a pin into the hole for setting of time and day. The adjustment must be made for summer and winter time.
2. Daily use of the thermostat
4-event clock mode
The day has been split into 4 events describing a typical day. When the thermostat is in 4-event mode it will automatically adjust the temperature according to the required temperature to the required time. As standard the thermostat has 5 days with 4 events, and 2 days with 2 events. Programming see 3.
Programming
4-event time and temperature
For each event, the start time and required temperature must be set. For example, in the morning you wish the heating to start at 07:00 and the temperature to rise to 25°C. Press OK ( ) button for 3 seconds and the start time is displayed. Change this to 07:00 with the UP (
) or DOWN (
) button. Press OK (
) to confirm.
The temperature is now displayed. Change this to 25°C with the UP ( ) or DOWN (
) button.
Press OK ( ) button to confirm. This action can now be repeated for the second event. These settings will be valid with days 1-5 showing on the display. To program days 6 and 7, repeat the above. Days 6 and 7 are usually Saturday and Sunday, and only have two events.
The temperature can be set within the range of +5 to +40°C. It is also possible to select the heating OFF at that event by reducing the setting to 5°C, and then pressing the ( ) once more.
Reset to factory setting
Press the pin button for 3 secs. and the thermostat returns to factory settings. Time and day is also reset and must be set according to “Setting the thermostat into operation”.
Factory settings
4-event time and temperature | |||||
Day 1-5 | Time | Temperature | |||
OCC2-1991
w/floor sensor |
OCC2-1999
w/room sensor |
||||
![]() |
06:00 | 25˚C | 20˚C | ||
![]() |
08:00 | 20˚C | 15˚C | ||
![]() |
16:00 | 27˚C | 22˚C | ||
![]() |
22:30 | 20˚C | 15˚C | ||
Day 6-7 | |||||
![]() |
08:00 | 27˚C | 22˚C | ||
![]() |
23:00 | 20˚C | 15˚C | ||
Hi-Low temp. | 55˚C / 5˚C | 28˚C / 15˚C | |||
4-event sequence | 5:2 | ||||
Scale | 24 H / ˚C | ||||
Adaptive control | ON |
6. Failure codes
E0 = Internal failure, replace thermostat
E1 = Built-in sensor short-circuit or disconnected, replace thermostat
E2 = External sensor short-circuit or disconnected