VIVE Comfort TP-Z-RISW ZONING Thermostat
Getting to know your `Zone Thermostat
- LCD
- Glow in the Dark Light Button
- Temperature Setpoint Keys
- Remote Name
- Operation Keys
Zone Thermostats
The remote should be mounted or placed approximately 4 to 5 feet above the floor. Select an area with average temperature and good air circulation.
Do not mount or place thermostats in following locations:
- Close to hot or cold air ducts
- That are in direct sunlight
- With an outside wall behind the thermostat
- In areas that do not require conditioning
- Where there are dead spots or drafts (in corners or behind doors)
- Where appliances could radiate heat
- Do not set it next to or on hot appliances
- Do not put it in your pocket or hold in your hands for a long period of time.
- Body heat will distort the temperature reading.
Wireless Range
Range between a zone thermostat and a master thermostat is approximately 100 feet with no obstructions and approximately 50 feet in standard residential metal, brick, and concrete construction
MOUNTING OPTIONS
Wall Mount – Permanent
- Remove the thermostat from the subbase
- Mount subbase to the wall
Wall Mount – Removeable
- Mount T-bracket on the Wall
- Slide the thermostat over the mounted T-bracket.
Desk or Counter Option
- Slide the T-bracket up into the slot holders
- T-bracket will stop on the top of the slot holders
INSTALLING BATTERIES
Installing Batteries for Temporary Wall Mount or Table Placement
- Use the finger tab on the back of the remote to remove the battery door.
- Once you have removed the door from the back of the remote, insert 2 AA Alkaline batteries and replace the battery door.
Inserting Batteries for Permanent Wall Mount
- Remove the thermostat from the subbase. It is held on the subbase by a plastic tab on the bottom of the remote sensor. Push in with a small at head screwdriver to remove it from the subbase.
- Once you have removed it from the subbase, insert 2 AA Alkaline batteries
- Attach the thermostat to the subbase by aligning the two top tabs and then close as shown
ESTABLISHING COMMUNICATION
Remember
Our Wireless Zoning System contains selectable wireless communication. Each component has a jumper switch labeled FSK and ASK. Default setting: FSK. All components must be set to the same position for wireless communication. This selectable communication option is available to you in case you have a device you are pairing with that only has the ASK option.
Connecting to Master Zone Thermostat
- The Remote Zone Thermostat must be configured to “ZONING” in the first Tech Setup Step. See next page.
- In the next Tech Setup Step, you select the Zone Number that the Remote Zone Thermostat will be used to measure/control. (See page 7 for steps to enter Tech Setup.) This will be Zones 2-5. (The Master
- Thermostat is always Zone 1)
- Then set the Master Thermostat Zone number to match the Remote Zone Thermostat. See the Installation Manual, Tech Setup Step “Zone Remote Thermostat”.
- With both Remote Zone Thermostat and set to the same zone in their setup steps, press and hold the light button on the zone thermostat until the Wireless Icon flashes, approximately 3 seconds.
- The Master Thermostat should now show the temperature of the Remote Zone Thermostat, the Zone number it’s configured for(Example-2), and it’s name. If it hasn’t been named yet, it will show
This zone thermostat has a technician setup menu for easy installer configuration. To set up the remote for your particular application
- Press and hold the LIGHT button for 3 seconds. This 3 second delay is designed so that homeowners do not accidentally access the installer settings
- Configure the installer options as desired using the table below.
- Use the key to move to the next tech setup step.
- Use the key to make adjustments to the settings.
System Select | Zone Selection | Remote Name | Show Set |
This step configures this device to connect to a wireless THERMOSTAT or a wireless ZONING system master thermostat.
Change setting to zoning for this application. |
This step links the device to the Master Thermostat, for the Zone # you wish to control.
Select the same zone # on this ZONE THERMOSTAT that you select on the Master thermostat (see page 6). While they are both showing the same zone #, press and hold the light button on the ZONE thermostat to link. |
This step selects a name for the zone thermostat. This name will also appear on the Master Thermostat when it is displaying the zone’s status. | ZONING
Enabling this feature will allow the zone remote to control the SYSTEM mode, FAN mode, and setpoint temperature of the zone.
Disabeling it will turn all control of that zone over to the master thermostat. |
LCD Will Show
Adjustment Options
Factory Default Settings
Room Temperature Calibration | F° or C° | Low-Temperature Setpoint Limit | High-Temperature Setpoint Limit |
This feature allows the installer to change the calibration of the room temperature display. For example, if the thermostat reads 70° and you would like it to read 72° then select
+2. |
This feature sets the display temperature to read either Fahrenheit or Celsius. | This feature allows you to set a minimum cool setpoint value. The setpoint temperature cannot be lowered below this value. | This feature allows you to set a maximum heat setpoint value. The setpoint temperature cannot be raised above this value. |
. |
|||
LCD Will Show
Adjustment Options
Factory Default Settings
Specifications
- The display range of temperature 32ºF to 99ºF (0ºC to 37ºC)
- The control range of temperature 44ºF to 90ºF (7ºC to 32ºC)
- Display accuracy ± 1ºF
- Power source Battery power from 2 AA Alkaline batteries
- Operating temperature 32ºF to +105ºF (0º to +41ºC)
- Operating humidity 90% non-condensing maximum
- Dimensions of thermostat 2.75”W x 4.5 ”H x 1.375”D
- Frequency 916 MHz
- Reading Temperature Every 60 seconds
TP-Z-RISW
(For use with TP-Z-955W Zoning Thermostat)
Congratulations on purchasing our Wireless Zoning Syste m.
This Zone Thermostat was designed to the highest reliability and ease of use standards. Thank you for choosing our quality products.
VIVE
- VIVE Comfort
- P.O. Box 3377
- Springfield, MO 65804
- Toll-Free: 1-800-776-1635
- Web: www.vivecomfort.com
- Hours of Operation: M-F 9AM – 6PM Eastern
REFERENCE
DOWNLOAD MANUAL
VIVE Comfort TP-Z-RISW ZONING Thermostat INSTALLATION MANUAL
VIVE Comfort TP-Z-RISW ZONING Thermostat INSTALLATION MANUAL
Leave a Reply