Venstar-logo

Venstar T1000FS Programmable Thermostat

Venstar T1000FS Programmable Thermostat

PREPARATION

REMOVE & REPLACE OLD THERMOSTAT

For best operation, install the thermostat in a junction box that is free from drafts that originate inside the wall.

WIRE CONNECTIONS

If the terminal designations on your old thermostat do not match those on the new thermostat, refer to the chart below, or the wiring diagrams that follow. Venstar T1000FS Programmable Thermostat fig-3

C may not be used on all systems.
O/B is used if your system is a Heat Pump.

Sample Wiring Diagrams

Gas or Electric Heat

5 Wire, 1 Stage Cooling, 1 Stage Gas Heat
Residential Gas or Electric Heat*, Electric Cool, split systems & package units Venstar T1000FS Programmable Thermostat fig-4

* If using first stage electric heat, this option must be selected ON (see page 12, step 6 of Owner’s Manual).

4 Wire, 1 Stage Cooling, 1 Stage Gas Heat
Residential Gas or Electric Heat*, Electric Cool, split systems & package units Venstar T1000FS Programmable Thermostat fig-5

* If using first-stage electric heat, this option must be selected ON (see page 12, step 6 of Owner’s Manual).

6 Wire, 2 Stage Cooling, 1 Stage Gas Heat
Residential two stage cooling with Gas or Electric Heat*. Venstar T1000FS Programmable Thermostat fig-6

* If using first stage electric heat, this option must be selected ON (see page 12, step 6 of Owner’s Manual).

6 Wire, 1 Stage Cooling, 2 Stage Heat
Residential & commercial 1 Stage Cooling, with 2 Stage Gas or Electric Heat* Venstar T1000FS Programmable Thermostat fig-7

* If using first stage electric heat, this option must be selected ON (see page 12, step 6 of Owner’s Manual).

7 Wire, 2 Stage Cooling, 2 Stage Heat
Commercial Gas or Electric Heat *, Electric Cool, split systems & package units including Commercial Heat Pumps **Venstar T1000FS Programmable Thermostat fig-8

If using first stage electric heat, this option must be selected ON (see page 12, step 6 of Owner’s Manual).
** Commercial heat pumps do not have the heat pump turned ON in advanced setup (see page 12, step 4 of Owner’s Manual).

Heat Pump

5 Wire, 1 Stage Cooling, 1 Stage Heat-Heat Pump* with O or b reversing valve**.
Residential Heat Pumps, split systems & package units, with no auxiliary heat.  Venstar T1000FS Programmable Thermostat fig-9

This option must be selected ON during advanced setup (see page 12, step 4 of Owner’s Manual).
This option must be selected O or b during advanced setup (see page 12, step 5 of Owner’s Manual).

6 Wire, 1 Stage Cooling, 2 Stage Heat-Heat Pump* with O or b reversing valve**.
Residential Heat Pumps, split systems & package units, with auxiliary heat.Venstar T1000FS Programmable Thermostat fig-10

* This option must be selected ON during advanced setup (see page 12, step 4 of Owner’s Manual).
** This option must be selected O or b during advanced setup (see page 12, step 5 of Owner’s Manual).

TEST OPERATION

TROUBLESHOOTING

REFERENCE:

Download Manual: 

Venstar T1000FS Programmable Thermostat Installation Instructuion

OTHER MANUALS

Venstar T1000FS Programmable Thermostat Owner Manual

Venstar-logo

Venstar T1000FS Programmable Thermostat Installation Instructuion

Leave a Reply

Your email address will not be published. Required fields are marked *

To respond on your own website, enter the URL of your response which should contain a link to this post's permalink URL. Your response will then appear (possibly after moderation) on this page. Want to update or remove your response? Update or delete your post and re-enter your post's URL again. (Find out more about Webmentions.)