Trane-TAYSTAT 570-Electric-Thermostat-product

Trane TAYSTAT 570 Electric Thermostat Owner Guide

TRANE-LOGO

Trane TAYSTAT 570 Electric Thermostat

Trane-TAYSTAT 570-Electric-Thermostat-product

FEATURES

The Trane Co. sells comfort systems. Comfort is achieved by matching the correct equipment and controls. This thermostat is designed to provide maximum comfort for your needs. Some of the basic offerings are:

  • Simple and easy to use. TheTrane-TAYSTAT 570-Electric-Thermostat-fig.1keys make it easy for you to change your temperature setting.
  • Large digital display. You can easily read the current room temperature at a glance.
  • No need for batteries. Batteries are not required because your temperature settings are held permanently in memory.

SETTINGS

Setting SYSTEM and FAN Switches
System and fan settings are controlled by using SYSTEM and FAN switches located on the bottom of the thermostat case

First set the SYSTEM switch

  • Cool: Normal setting for months when your home needs cooling (air conditioning). The digital display shows a snowflakeTrane-TAYSTAT 570-Electric-Thermostat-fig.2 when cooling is on.
  • Off: Both heating and cooling are off.
  • Heat: Normal setting for months when your home needs heating. The digital display shows a flameTrane-TAYSTAT 570-Electric-Thermostat-fig.3 when the heating is on.
  • Em. Ht.: Switch to this setting when your home needs heat, but your equipment needs servicing or is not working properly. In this mode, the thermostat controls only the backup heat. The heat pump is off.Trane-TAYSTAT 570-Electric-Thermostat-fig.4

Then set the FAN switch:

Auto: Normal setting for most homes. Some systems may delay the fan from turning on and off with the equipment.
On: The fan runs continuously. Use for improved air circulation and air quality.Trane-TAYSTAT 570-Electric-Thermostat-fig.5

Emergency Heat
The Emergency Heat feature allows you to Òturn onÓ the electric heat section of the system by moving the system switch to the Em. Ht. position. The indicatorTrane-TAYSTAT 570-Electric-Thermostat-fig.6 flashes and points to Em Ht when the system is in emergency heat mode. The Trane-TAYSTAT 570-Electric-Thermostat-fig.6indicator may also point to Aux Ht if the system calls for additional backup heating.Trane-TAYSTAT 570-Electric-Thermostat-fig.7

Auxiliary Heat
The auxiliary heaters assist the heat pump under normal conditions when low outdoor temperature occurs. TheTrane-TAYSTAT 570-Electric-Thermostat-fig.6 indicator points to Aux Ht when the auxiliary heating equipment operates.

Displaying Temperature Setting

The temperature setting and the room temperature display separately. The Trane-TAYSTAT 570-Electric-Thermostat-fig.6 indicator points to Set when the temperature setting displays, and to Room when the room temperature displays. The thermostat displays room temperature unless Trane-TAYSTAT 570-Electric-Thermostat-fig.1 is pressed.

  • To display the temperature setting on the digital display, press either the Trane-TAYSTAT 570-Electric-Thermostat-fig.1 key once.Trane-TAYSTAT 570-Electric-Thermostat-fig.8

Changing Temperature Setting

  • To lower the temperature setting, press theTrane-TAYSTAT 570-Electric-Thermostat-fig.6 key. When in the heating mode, lowering the temperature at night or during the day can lower your energy costs.Trane-TAYSTAT 570-Electric-Thermostat-fig.9
  • To raise the temperature setting, press the Trane-TAYSTAT 570-Electric-Thermostat-fig.6 key. When in the cooling mode, raising the temperature before you leave for work or school also lowers your energy costs.Trane-TAYSTAT 570-Electric-Thermostat-fig.10

CAUTION
Equipment Damage Hazard. Can cause permanent damage to the compressor or other equipment. To avoid possible equipment damage, do not operate the cooling when the outside temperature is below 50°F (10°C). See equipment manufacturer instructions. To avoid possible compressor damage, allow the compressor to remain off for five minutes before restarting.

TROUBLESHOOTING

Symptom Action
Heating or Cooling will not come on. Check that the SYSTEM switch on the thermostat is set to Heat or Cool. Check if the circuit breaker is tripped—reset the circuit breaker.

Check if the fuse is blown—replace the fuse. Check for air movement at the register.

Check power to the heating or cooling equipment.

Temperature setting is too warm or cool. Adjust the temperature by pressing either the ▲ or ▼ key.

WARRANTY

LIMITED WARRANTY

Low Voltage Room Thermostats
This warranty is extended by American Standard Inc., to the original purchaser and to any succeeding owner of the real property to which the Thermostat is originally affixed, and applies to products purchased and retained for use within the U.S.A. and Canada. If any part of your Thermostat fails because of a manufacturing defect within one year from the date of the original purchase, Warrantor will furnish, without charge, a new thermostat. Any local transportation, related service labor and diagnosis calls are not included. This warranty does not cover the failure of your Thermostat if it is damaged while in your possession or if the failure is caused by unreasonable use. In no event shall Warrantor be liable for incidental or consequential damages. In no event shall any implied warranty of merchandise or fitness for use exceed the terms of the limited warranty stated above. Some states do not allow limitations on how long an implied warranty lasts or do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Parts will be provided by our factory organization or an authorized service organization in your area. All you need to do is look us up in the Yellow Pages or write to the address given below. If you wish further help or information concerning this warranty, contact:

  • American Standard Inc.
  • Troup Highway Tyler, TX 75711-9010
  • Attention: Manager, After Sales Support

CUSTOMER ASSISTANCE

If, after reading this guide, you have any questions concerning the operation of your thermostat, please call the Thermostat Customer Assistance Helpline at 1-877-880-3381, Monday-Friday, 7:00 am-5:30 p.m., Central time. For service, contact your local heating and cooling contractor.

REFERENCE:

DOWNLOAD MANUAL:

Trane TAYSTAT 570 Electric Thermostat Owner Guide

TRANE-LOGO

Trane TAYSTAT 570 Electric Thermostat Owner Guide


Posted

in

by

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *