Honeywell

Honeywell CT1500 Timer Thermostat 

Honeywell-CT1500-Timer-Thermostat 

INSTALLATION MANUAL

CT1500-24 V gas or oil heat.
CT1501-24 V gas or oil heat/ cool.
CT1502-24 V central electric heat/ cool or single stage heat pump without auxiliary heat.
CT1503-750 millivolt heat.
NOT FOR USE ON LINE VOLTAGE (120 V) SYSTEMS.
Any questions concerning the application of this thermostat should be directed to Honeywell Consumer Services at 1-800-468-1502, Monday-Friday 7:30 a.m.-5:00 p.m., Central time.

THERMOSTAT FEATURES

Front of thermostat.

Honeywell-CT1500-Timer-Thermostatfig-1

Cover removed

Honeywell-CT1500-Timer-Thermostatfig-2

PREPARATION

Check thermostat and wall plate suitability for your heating or heating/cooling system. Refer to Table 1.

Honeywell-CT1500-Timer-Thermostatfig-26

Thermostat must be mounted on wallplate or subbase included in package to assure operation.

Assemble tools required, as illustrated.

Honeywell-CT1500-Timer-Thermostatfig-3

If wallplate or subbase is mounted on a vertical outlet box (check old installation), order 196393A Cover Plate and Adapter Ring (see appro­priate figure under step 4). Call Honeywell Consumer Services (1-800-468-1502) for ordering information, Monday-Friday, 7:30 a.m. to 5:00 p.m. Central time.
Test to make certain that your heating and cooling systems are working. If either one does not work, contact your local heating/air conditioning dealer.
NOTE: Do not operate cooling system if outdoor temperature is below 50° F [10° C].
Turn off power to the heating/cooling system at the main fuse panel.

UNPACK THERMOSTAT

REMOVE OLD THERMOSTAT

One or two extra wires?
If you are replacing a Honeywell Chronotherm thermostat, you may find one or two wires that go to the clock terminals on the Chronotherm thermostat wiring wallplate. Do not allow them to touch, or you may damage your transformer. Disconnect the wires, and wrap them separately, using electrical tape. Do not wrap them together. Place the wires where they will not interfere with the operation of the new thermostat. Record the colors and terminal designation labels of the rest of the wires.

MOUNT WALLPLATE OR SUBBASE

WIRE WALLPLATE OR SUBBASE

NOTE: All wiring must comply with local electrical codes and ordinances.
Refer to illustration and strip thermostat wire insulation as necessary.

Honeywell-CT1500-Timer-Thermostatfig-12For CT1500 heating-onlyHoneywell-CT1500-Timer-Thermostatfig-13

For CT1501 heating/cooling
Connect the wires to matching terminals on the subbase.

Honeywell-CT1500-Timer-Thermostatfig-14

NOTE: If there are four wires, connect wire marked R to terminal RH and add a jumper wire to connect to RC. If RC is left uncon­nected, the air conditioner will not turn on. The 4-wire drawing on this page shows how to jumper RC to RH. Str ip the insulation off the wire where it connects to the terminals. Fir mly tighten screws.Honeywell-CT1500-Timer-Thermostatfig-15

If the labels do not agree with the terminal designations on your new subbase:

TABLE 2-TERMINAL DESIGNATIONS.

OLD SUBBASE TERMINAL  

CONTROL FUNCTION

R or RH Heating transformer power to control circuit.
RC Cooling transformer power to control circuit
w Heating relay or valve.
y Cooling relay.
G Fan relay.
B Heating changeover valve or damper control circuit.
0 Cooling changeover valve or damper control circuit.
p

Heat pump compressor control circuit.

For CT1502 heating/coolingHoneywell-CT1500-Timer-Thermostatfig-16Honeywell-CT1500-Timer-Thermostatfig-17

  1. POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REOUIRED
  2. IF COMPRESSOR IS CONNECTED TO OLD THERMOSTAT’S r TERMINAL WITH A JUMPER To ·w-, USE NEW THERMOSTAT’S  p” TERMINAL FOR COMPRESSOR. IF OLD THERMOSTAT HAS ONE WIRE TO •y• A O ONE TO “W-, USI: •y- AND -W” ON EW THERMOSTAT: DO NOT USE “P- IMPORT A T- IF OLD THERMOSTAT USES A W2 (AUXJLJARY OR EMERGENCY HEAT) TERMI AL, THIS THERMOSTAT MAY NOT BE USED THIS THERMOSTAT IS NOT DESIGNED TO CONTROL AUXILIARY HEAT.

Connect the wires to matching terminals on the subbase. Firmly tighten screws. Push excess wire back into wall, and plug hole in wall with nonflammable insulation to prevent drafts from affecting thermostat operation.

For CT1503 750-millivolt heating 
Connect either wire to R terminal and the other wire to W terminal. Firmly tighten screws.
Push excess wire back into wall, and plug hole in wall with nonflammable insulation to prevent drafts from affecting thermostat operation. Honeywell-CT1500-Timer-Thermostatfig-18

MOUNT THE THERMOSTAT

Note the tabs on the top inside edge of the thermostat base. These fit the slots molded into the top of the wallplate or subbase.
Hang the thermostat base on the wallplate or subbase as shown in illustration.
Insert the two captive mounting screws located in the bottom corners of the thermo­stat base (see illustration); firmly tighten.
IMPORTANT Do NOT cycle heating system until Step 7 is completed. Honeywell-CT1500-Timer-Thermostatfig-19

SET HEAT ANTICIPATOR LEVER

NOTE: Not applicable on CT1503 millivolt model.

If current rating is still unavailable, proceed as follows:

IMPORTANT Most hot water systems require a setting of 1.3 times the valve current rating.

INSTALL TIMER BATTERIES

SET TIMER

ATTACH THERMOSTAT COVER

CHECK OUT THERMOSTAT OPERATION AND SET TEMPERATURE CONTROL LEVERS 
The two levers on top of the thermostat control the low and high temperature for energy savings and comfort control, as shown in illustration. Honeywell-CT1500-Timer-Thermostatfig-25

CAUTION Do NOT check operation by shorting across terminals of relay or valve coil; this will burn out the thermostat heat anticipator, which will void the warranty.

Heating-only System

Important: If thermostat fails any test. refer to trouble­shooting guide in owner’s manual.

Heating/Cooling System

IIMPORTANT To avoid compressor damage, do not operate the cooling system if outdoor temperature is below 50 ° F [10° C]. Refer to manufacturer’s recommendations.

IMPORTANT If thermostat fails any test, refer to trouble­shooting guide in owner’s manual.

For heating season:

For cooling season:

IF YOU HAVE QUESTIONS REGARDING THE INSTALLATION OF THE HONEYWELL FUEL SA VER TH ER MOST AT, PLEASE CALL OUR TOLL­FREE CONSUMER SERVICES GROUP NUMBER AT 1-800-468-1502, MONDAY-FRIDAY, 7:30 AM. 5:00 PM CENTRAL TIME.

Residential and Building Controls Division Honeywell Inc.
1985 Douglas Drive No. Golden Valley, MN 55422

Re idential and Building Controls Division
Honeywell Limited-Honeywell Limitee 740 Ellesmere Road
Scarborough, Ontario
MlP 2V9

Reference

Download Manual:

Honeywell CT1500 Timer Thermostat Installation Manual

OTHER MANUALS

Honeywell CT1500 Timer Thermostat Owners Manual

Honeywell

Honeywell CT1500 Timer Thermostat Installation Manual

Leave a Reply

Your email address will not be published. Required fields are marked *

To respond on your own website, enter the URL of your response which should contain a link to this post's permalink URL. Your response will then appear (possibly after moderation) on this page. Want to update or remove your response? Update or delete your post and re-enter your post's URL again. (Find out more about Webmentions.)