Terneo KT SMART Thermostat

Terneo-KT-SMART-Thermostat-product

Terneo kt thermostat is designed for the organization of snow and ice melting systems, which ensure the safety of people and vehicles, as well as reduce damage to buildings in the winter period. When the readings of the air temperature sensor are within the range of +5…–10 ° (adjustable), the thermostat turns on the load.

IN THE BOX

TECHNICAL DATA

The limits of regulation upper: 0…10 °С

lower: –20…–1 °С

Maximum load current (for category AC-1) 16 А
Rated load capacity (for category AC-1) 3 000 VА
Input voltage 230 V ±10 %
Weight in the complete set 0,18 kg ±10 %
Overall dimensions (w × h × d) 75 × 75 × 39 mm
Temperature sensor NTC thermo-resistor 10 kOhm 25 °C (R10)
The length of the sensor-connected cable 3 m
Number combinations under heat, at least 50 000 cycles
Number of combinations without heating, no less than 20 000 000 cycles
Degree of protection GOST14254 IP20
Measured temperature range –30…+90 °С

IMPORTANT: Before the installation and operation of the device, please read by the end of this ocument. This will help to avoid possible danger, mistakes and misunderstandings.

WIRING

Terneo-KT-SMART-Thermostat-fig-1

Terneo-KT-SMART-Thermostat-fig-2

RELIABILITY OF THE POWER RELAY provides protection against frequent switching in the thermostat. If there was less than 1 minute between relay switching, the relay activation will be delayed, marking the countdown with a flashing dot.

IN THE CASE OF INCORRECT WIRING, is possible failure of the thermostat. Make sure that external sensor and mains voltage are connected correctly.

INSTALLATION

The thermostat is designed for indoor installation. The ingress risk of moisture or liquid into the place of installation must be minimized. When installed in a bathroom, toilet, kitchen, swimming pool the thermostats should be installed at the place out of reach of casual spraying. The ambient temperature during installation must be between -5 .. + 45 °C. The installation height of the thermostat should be in the range 0,4…1,7 m above the floor level. The thermostat is mounted and connected after the installation and load testing. To protect against short-circuit in the load circuit the circuit breaker (CB) has to be installed before installing the thermostat. The circuit breaker is installed in the gap of phase conductor, as shown in Wiring 1. It should be designed for not more than 16 A.

To protect a people against electric shock leakage is installed the SSD (safety shutdown device). This event is obligatory when installing floor heating in wet areas. For working of SSF the heating cable screen must be grounded (connected to the protective conductor PE) or, if there is a two-wire network, it is necessary to make protective neutral earthing. That is to connect the screen to a zero before SSF. In Wiring 1 protective neutral earthing is shown with a dotted line.

The thermostat is mounted in the standard mounting box 60 mm in diameter, with mounting screws.

For installation, vou must

The thermostat terminals are designed for a wire with section not more than 2.5 mm?. To reduce the mechanical loads on the terminals it is desirable to use a soft wire. The ends of the wires must be cleaned and crimped with ferrules with insulation. The wires are tightened in the terminals using a screwdriver with a blade width no more than 3 mm. A screwdriver with a blade width more than 3 mm can cause mechanical damage to the terminals. This may result in the loss of right for warranty. The terminals should be tightened with torque 0,5 N-m.

It is necessary for the temperature controller to switch the current to no more than 2/3 of the maximum current specified in the specification. If the current exceeds this value, the load must be connected through a contactor (magnetic actuator, power relay), which is optimized for this current (Wiring 2). The sections of the wires, which is connected to the thermostat, must be at least: copper 2 × 1,0 mm. The use of aluminum is not desirable.

Mounting the sensor

Terneo-KT-SMART-Thermostat-fig-3

Air temperature sensor should be mounted on the wall or under the edge of the roof in order to ensure its protection from direct sunlight, rain and snow, and ensure the opportunity for easy replacement in the event of a malfunction or damage (Figure 1). If necessary, it is allowed to shorten and expand sensor connecting wires (separate cable not more than 40 m long with a cross-section greater than 0,75 mm ). Power wires should not be placed near connection wire of sensor. otherwise they may cause interference.

WARRANTY TERMS

WARRANTY CARD

Terneo-KT-SMART-Thermostat-fig-4

EXPLOITATION

To view the menu items, hold down the « Terneo-KT-SMART-Thermostat-fig-16 » button for a certain number of seconds (see Table 1). Use « Terneo-KT-SMART-Thermostat-fig-10 » and «Terneo-KT-SMART-Thermostat-fig-11 » to change parameters. Upon first press – the parameter flashes, the second press – it is available for modification. 3 seconds after pressing the thermostat returns to the display of the current temperature. In the waiting mode (when the buttons aren’t currently being used the brightness of the indicator and the screen will be reduced to 30 %.

Preset temperature

(factory settings: upper limit 5 °C; lower limit –10 °C)

To view the upper limit, press the button Terneo-KT-SMART-Thermostat-fig-10and to view the lower limit press – Terneo-KT-SMART-Thermostat-fig-11. Use the Terneo-KT-SMART-Thermostat-fig-10orTerneo-KT-SMART-Thermostat-fig-11 buttons to change the flashing value. If the temperature of the sensor is within the set limits, the heater will turn on and the red indicator will light up.

Switching to sleep mode

Button blocking

(child and public protection)

Table 1: FUNCTION MENU

Terneo-KT-SMART-Thermostat-fig-17

POSSIBLE PROBLEMS, CAUSES AND WAYS TO OVERCOME THEM

While load is running, the screen shows «ЗНЕ»

While the load is running, the screen displays «OTerneo-KT-SMART-Thermostat-fig-19»

Load is off, screen and indicator are off

The load does not work, theTerneo-KT-SMART-Thermostat-fig-20 flashes on the screen

Every 5 seconds the screen displays «Ert»

ADDITIONAL INFORMATION

Таble 2: RESISTANCE OF EXTERNAL TEMPERATURE SENSOR at different ambient temperatures

Terneo-KT-SMART-Thermostat-fig-21

SAFETY INSTRUCTIONS

vс25_220926

Low Voltage Directive: 2014/35/EU
EMC Directive: 2014/30/EU

Terneo-KT-SMART-Thermostat-fig-15

Contacts

Manufacturer and vendor: DS ELECTRONICS, LTD

SERVICE CENTER CONTACT

Reference

Download Manual:

Terneo KT SMART Thermostat Installation Manual

Terneo-logo

Terneo KT SMART Thermostat Installation Manual

Leave a Reply

Your email address will not be published. Required fields are marked *

To respond on your own website, enter the URL of your response which should contain a link to this post's permalink URL. Your response will then appear (possibly after moderation) on this page. Want to update or remove your response? Update or delete your post and re-enter your post's URL again. (Find out more about Webmentions.)