Tekmar 532_Q Non-Programmable Thermostat Quick Start Guide

Tekmar-LOGO

Tekmar 532_Q Non-Programmable Thermostat

Tekmar-532_Q-Non-Programmable-Thermostat-PRODUCT

NOTICE
The information contained herein is not intended to replace the full product installation and safety information available or the experience of a trained product installer. You are required to thoroughly read all installation instructions and product safety information before beginning the installation of this product.

Location

Tekmar-532_Q-Non-Programmable-Thermostat-FIG.1

Remove Mounting Base

Tekmar-532_Q-Non-Programmable-Thermostat-FIG.2

Installation to Wall

Tekmar-532_Q-Non-Programmable-Thermostat-FIG.3

Installation to Gang Box

Tekmar-532_Q-Non-Programmable-Thermostat-FIG.4

Wiring

Tekmar-532_Q-Non-Programmable-Thermostat-FIG.5

Switch Settings

Tekmar-532_Q-Non-Programmable-Thermostat-FIG.6

Switch On Position Off Position
1 Schedule On Schedule Off
2 Scenes On Scenes Off
3 Locked Unlocked

User Interface

Tekmar-532_Q-Non-Programmable-Thermostat-FIG.7

Settings

The following settings are essential to the successful operation of the heating system.
PressTekmar-532_Q-Non-Programmable-Thermostat-FIG.8Together

  • Press and hold down both the Tekmar-532_Q-Non-Programmable-Thermostat-FIG.9buttons for 3 seconds to change from one step to the next.
  • Release both buttons once the step has been reached.
  • Press the Tekmar-532_Q-Non-Programmable-Thermostat-FIG.9the button to change the setting, if available.
  • Press AND hold down both theTekmar-532_Q-Non-Programmable-Thermostat-FIG.9buttons for 3 seconds to go to the next step, OR
  • After 15 seconds of no button activity, the display goes back to normal operation.
Setting
The following settings are available when the thermostat is locked or unlocked.
MODE

Select heat or off.

SET ROOMTekmar-532_Q-Non-Programmable-Thermostat-FIG.10

Set the room temperature while in the occupied time period. Available when a room sensor is connected.

SET ROOMTekmar-532_Q-Non-Programmable-Thermostat-FIG.11

Set the room temperature while in the unoccupied time period. Available when a room sensor is connected and a schedule or scenes are selected.

SET ROOM AWAY

Set the room temperature while in the away scene. Available when a room sensor is connected and a schedule or scenes are selected.

SET FLOORTekmar-532_Q-Non-Programmable-Thermostat-FIG.10

Set the floor temperature while in the occupied time period. Available when an auxiliary floor sensor is connected.

SET FLOORTekmar-532_Q-Non-Programmable-Thermostat-FIG.11

Set the floor temperature while in the unoccupied time period. Available when an auxil- iary floor sensor is connected and the schedule or scenes switch settings are on. “Off” is the factory default when there are both room air and floor temperature sensors.

LIGHT

Select when the display backlight should operate. Auto operates the backlight for 30 seconds after a keystroke.

UNITS

Select the temperature units.

TYPE AND SOFTWARE VERSION

Device Type number. Hold the button to view the software version and view any system overrides.

ADDRESS

The tekmarNet® address is shown in the large number field. The address and “Auto” are alternated when using automatic addressing.

SCHEDULE
The thermostat can follow a shared network schedule. Select to follow either schedule master 1, 2, 3 or 4. Requires tekmarNet.
Setting
The following settings are available when the thermostat is unlocked.
SET LIMIT ROOM MAXTekmar-532_Q-Non-Programmable-Thermostat-FIG.10

Set the max room temperature limit while in the occupied time period. Available when a room sensor is connected.

SET LIMIT ROOM MAXTekmar-532_Q-Non-Programmable-Thermostat-FIG.11

Set the max room temperature limit while in the unoccupied time period. Available when a room sensor is connected and a schedule or scenes are selected.

SET LIMIT ROOM MIN

Set the min room temperature limit for both occupied and unoccupied time periods. Available when a room sensor is connected and schedules or scenes are selected.

SET FLOOR MAX

Set the max floor temperature in order to protect the floor covering. Available when an auxiliary floor sensor is connected. Suggested settings: Tile = 90°F (32°C), Wood Floor

= 85°F (29°C)

SENSOR 1

Select the type of sensor connected to auxiliary input 1. Available when a sensor is automatically detected.

SENSOR 2

Select the type of sensor connected to auxiliary input 2. Available when a sensor is automatically detected.

ROOM SENSOR

Select when the built-in room temperature sensor is on or off. The built-in room sensor can only be disabled when an auxiliary room or floor sensor is connected.

AIR GROUP

Select if this thermostat should be included in an air group to interlock heating and cooling for the group. Requires tekmarNet.

W PUMP

During a heat call, select whether the tN4 system control’s pump should turn on or be off to allow a zone group pump per manifold. Requires tekmarNet.

W DELAY

During a heat call, select whether the tN4 system control’s pump should be delayed by 3 minutes to allow manifold thermal actuator zone valves to open. Requires tekmarNet.

For a full list of settings and operational details, please refer to the Thermostat Installation and Operation Manual 532_D which is available from www.tekmarControls.com
Product design, software, and literature are Copyright ©2015 by tekmar Control Systems Ltd., A Watts Water Technologies Company.
Head Office: 5100 Silver Star Road, Vernon, B.C.
Canada V1B 3K4, 250-545-7749, Fax. 250-545-0650
Web Site: www.tekmarControls.com

REFERENCE

DOWNLOAD MANUAL

Tekmar 532_Q Non-Programmable Thermostat Quick Start Guide

Tekmar-LOGO

Tekmar 532_Q Non-Programmable Thermostat Quick Start Guide