Tekmar 532_Q Non-Programmable Thermostat
NOTICE
The information contained herein is not intended to replace the full product installation and safety information available or the experience of a trained product installer. You are required to thoroughly read all installation instructions and product safety information before beginning the installation of this product.
Location
Remove Mounting Base
Installation to Wall
Installation to Gang Box
Wiring
Switch Settings
Switch | On Position | Off Position |
1 | Schedule On | Schedule Off |
2 | Scenes On | Scenes Off |
3 | Locked | Unlocked |
User Interface
Settings
The following settings are essential to the successful operation of the heating system.
PressTogether
- Press and hold down both the buttons for 3 seconds to change from one step to the next.
- Release both buttons once the step has been reached.
- Press the the button to change the setting, if available.
- Press AND hold down both thebuttons for 3 seconds to go to the next step, OR
- After 15 seconds of no button activity, the display goes back to normal operation.
Setting |
The following settings are available when the thermostat is locked or unlocked. |
MODE
Select heat or off. |
SET ROOM
Set the room temperature while in the occupied time period. Available when a room sensor is connected. |
SET ROOM
Set the room temperature while in the unoccupied time period. Available when a room sensor is connected and a schedule or scenes are selected. |
SET ROOM AWAY
Set the room temperature while in the away scene. Available when a room sensor is connected and a schedule or scenes are selected. |
SET FLOOR
Set the floor temperature while in the occupied time period. Available when an auxiliary floor sensor is connected. |
SET FLOOR
Set the floor temperature while in the unoccupied time period. Available when an auxil- iary floor sensor is connected and the schedule or scenes switch settings are on. “Off” is the factory default when there are both room air and floor temperature sensors. |
LIGHT
Select when the display backlight should operate. Auto operates the backlight for 30 seconds after a keystroke. |
UNITS
Select the temperature units. |
TYPE AND SOFTWARE VERSION
Device Type number. Hold the button to view the software version and view any system overrides. |
ADDRESS
The tekmarNet® address is shown in the large number field. The address and “Auto” are alternated when using automatic addressing. |
SCHEDULE The thermostat can follow a shared network schedule. Select to follow either schedule master 1, 2, 3 or 4. Requires tekmarNet. |
Setting |
The following settings are available when the thermostat is unlocked. |
SET LIMIT ROOM MAX
Set the max room temperature limit while in the occupied time period. Available when a room sensor is connected. |
SET LIMIT ROOM MAX
Set the max room temperature limit while in the unoccupied time period. Available when a room sensor is connected and a schedule or scenes are selected. |
SET LIMIT ROOM MIN
Set the min room temperature limit for both occupied and unoccupied time periods. Available when a room sensor is connected and schedules or scenes are selected. |
SET FLOOR MAX
Set the max floor temperature in order to protect the floor covering. Available when an auxiliary floor sensor is connected. Suggested settings: Tile = 90°F (32°C), Wood Floor = 85°F (29°C) |
SENSOR 1
Select the type of sensor connected to auxiliary input 1. Available when a sensor is automatically detected. |
SENSOR 2
Select the type of sensor connected to auxiliary input 2. Available when a sensor is automatically detected. |
ROOM SENSOR
Select when the built-in room temperature sensor is on or off. The built-in room sensor can only be disabled when an auxiliary room or floor sensor is connected. |
AIR GROUP
Select if this thermostat should be included in an air group to interlock heating and cooling for the group. Requires tekmarNet. |
W PUMP
During a heat call, select whether the tN4 system control’s pump should turn on or be off to allow a zone group pump per manifold. Requires tekmarNet. |
W DELAY
During a heat call, select whether the tN4 system control’s pump should be delayed by 3 minutes to allow manifold thermal actuator zone valves to open. Requires tekmarNet. |
For a full list of settings and operational details, please refer to the Thermostat Installation and Operation Manual 532_D which is available from www.tekmarControls.com