Tekmar 518 Thermostat
Location
Remove Mounting Base
Installation to Wall
Installation to Gang Box
Wiring
User Interface
Critical Settings
The following settings are essential to the successful operation of the heating system.
- Press and hold down both the
buttons for 3 seconds to change from one step to the next.
- Release both buttons once the step has been reached.
- Press the
the button to change the setting, if available.
- Press and hold down both the
buttons for 3 seconds to go to the next step, OR
- After 15 seconds of no-button activity, the display goes back to normal operation.
Display | Setting |
User settings. | |
![]() |
MODE Select heat or off. |
|
UNITS Select the temperature units in degrees Fahrenheit or Celsius. |
![]() |
BACKLIGHT
Select when the display backlight should operate. Options are Off Auto, and On. Auto operates the backlight for 30 seconds after a keystroke. |
|
SET FLOOR
Set the floor minimum temperature. Available when an auxiliary floor sensor is connected and the built-in room temperature sensor is on. |
![]() |
TYPE
Device Type number. Hold the button to view the software version. |
![]() |
ESCAPE
Release the |
Display | Setting |
Installer settings. Press the ![]() |
|
|
AUXILIARY SENSOR
Select the type of auxiliary sensor. Available when an auxiliary sensor is automatically detected. NONE = no auxiliary sensor, ROOM = Indoor Sensor, OUT = Outdoor Sensor, FLOR = Slab Sensor |
|
ROOM SENSOR
Select if the built-in room temperature sensor is on or off. The built- in room sensor can only be disabled when an auxiliary room or slab sensor is connected. |
![]() |
FLOOR MAXIMUM
Set the floor maximum temperature in order to protect the floor covering. Suggested settings: Tile = 90°F (32°C), Wood Floor = 85°F (29°C) |
![]() |
ESCAPE
Release the |
For a full list of settings and operational details, please refer to the thermostat Installation and Operation Manual 518_D is available from www.tekmarControls.com
Product design, software, and literature are Copyright ©2013 by tekmar Control Systems Ltd., A Watts Water Technologies Company. Head Office: 5100 Silver Star Road, Vernon, B.C. Canada V1B 3K4, 250-545-7749, Fax. 250-545-0650 Web Site: www.tekmarControls.com
REFERENCE:
Other Manual:
Tekmar 518 Thermostat User Manual
Tekmar 518 Thermostat Installation and Operation Manual
Tekmar 518 Thermostat Specification Sheet
Leave a Reply