sygonix lgoo

sygonix 1385634 Digital Room Thermostat Operating

sygonix 1385634 Digital Room Thermostat Operating-product

Operating instructions

Digital room thermostat
Item No. 1385634

Introduction

Dear Customer,
thank you for purchasing this product. This product complies with the statutory national and Euro-pean requirements. To maintain this status and to ensure safe operation, you as the user must observe these operating instructions! These operating instructions are part of this product. They contain important notes on commissioning and handling. Also consider this if you pass on the product to any third party. Therefore, retain these operating instructions for refe-rence! All company names and product names are trademarks of their respective owners. All rights reserved.
If there are any technical questions, please contact:
International: www.conrad.de/kontakt
United Kingdom: www.conrad-electronic.co.uk/contact 

Explanation of symbol

sygonix 1385634 Digital Room Thermostat Operating-fig-1The lightning symbol is used when your health is at risk.
sygonix 1385634 Digital Room Thermostat Operating-fig-2This symbol points out particular dangers associated with handling, function or operation.
sygonix 1385634 Digital Room Thermostat Operating-fig-3The arrow symbol indicates special advice and opera-ting information.
sygonix 1385634 Digital Room Thermostat Operating-fig-4Observe the operating instructions!

Intended use

The digital room thermostat serves automatic switching of a connected end device, according to the set or programmed times or the set temperatures. The room thermostat must only be operated with commer-cial batteries of type AAA/Micro. It is intended for indoor use only. Do not use it outdoors. Contact with moisture must be avoided under all circumstances. The safety notes and all other information in these operating instructions always have to be observed! Any use other than that described above can damage the product and may involve additional risks such as short cir-cuit, fire, electric shock, etc. No part of this product must be modified or converted! This product complies with the statutory national and Eu-ropean requirements. All company names and product names are trademarks of their respective owners.

4. Scope of delivery

Up-to-date operating instructions: 

  1. Open www.conrad.com/downloads in a browser or scan the displayed QR code.
  2. Select the document type and language and enter the item number into the search field. After submitting the query you can down-load displayed records.sygonix 1385634 Digital Room Thermostat Operating-fig-5

Feature

Safety information

The guarantee/warranty will expire if damage is in-curred resulting from non-compliance with the oper-ating instructions! We do not assume any liability for consequential damage! We do not assume any liability for property damage and personal injury caused by improper use or non-compli-ance with the safety instructions. In such cases the war-ranty/guarantee is voided.

Persons/Product

Batteries

Read the “Disposal” chapter for instructions on envi-ronmentally sustainable disposal of batteries.

Installation

The room thermostat must only be installed by a qual-ified specialist. Installation must only be performed ac-cording to the applicable local provisions. The room thermostat must not be installed near any windows, doors, heat sources or ventilation openings. Also avoid installation in locations where the device is exposed to direct sunlight. This may falsify the meas-ured room temperature. Keep a distance of approx. 1.5 m for this. Never cover the room thermostat with any other ob-jects. The device is only suitable for vertical wall mounting. We recommend a mounting height starting at approx. 1.5 m. Only install the device on a stable basis, e.g. ma-sonry. Observe the max. connection value of the room ther-mostat; see technical data. The installed relay is poten-tial-free.

The controller must only be installed when powered down. For this, power down the electrical mains supply that is con-nected to the relay of the room thermostat (circuit protection and FI-switch off) and secure it against unauthorized reac-tivation!

Check the mains supply line for voltage-freeness. Ensure that no present electrical or water lines are damaged during installation. The same applies, if only low voltage is to be supplied through the relay, since this may cause short circuit at in-stallation! Remove the battery holder at the bottom of the device. Turn the housing screw at the bottom of the controller out only until the upper shell of the room thermostat can be removed. Do not turn the housing screw out entirely. There is the dan-ger of losing the housing screw and the square nut. Now pull the upper shell of the controller off of the base plate. The base plate is attached on a recessed socket with the two enclosed screws. The base plate has four indentations for attachment for this purpose. Break out the two required attachment openings with a suitable tool. Route the mains line through the mains line opening of the base plate. Attach the base plate on the recessed socket with the two enclosed screws (figure 1). Check for tight fit of the base plate. Strip 5 mm of the cable insulation. Connect the supply line of the end device to the screw terminal NO (1) or NC (3) and COM (2).

The installed relay is potential-free. The connection ex-ample shows the connection to mains voltage 230 V/AC. Observe the maximum contact resilience; see chap-ter “Technical Data” and the operating instructions of the device that is to be controlled via the room thermo-stat, on how to set up the circuits.sygonix 1385634 Digital Room Thermostat Operating-fig-6

Push the upper shell onto the base plate (figure 2). Make sure that the supply lines are not crushed or damaged by this. The upper shell is now attached to the base plate again with the housing screw (figure 3).sygonix 1385634 Digital Room Thermostat Operating-fig-7

The room thermostat must only be operated with the correctly attached and screwed-on upper shell. If the upper shell is missing or wrongly installed, there is a danger to life from electric shock!

Inserting or replacing the batteries

Commissioning and operation

Observe Chapter “Safety information”!

Settings

The thermostat must be on. Push the buttons SET and OK at the same time to get to the setting mode. The relay switches off in setting mode. Change the values with the buttons “+” and “-”. Keep the re-spective button pressed for quick adjustment. If you do not push any button for approx. 60 seconds, the settings made until then are saved and setting mode is left. Push the OK button to save the setting and to leave the set-ting mode.

Setup

To switch to the setup settings, the thermostat must be in the position OFF.sygonix 1385634 Digital Room Thermostat Operating-fig-13

Change the values with the buttons “+” and “-”. Keep the re-spective button pressed for quick adjustment. If you do not push any button for approx. 60 seconds, the settings made until then are saved and setting mode is left. Push the OK and SET buttons for 5 seconds to save the input and switch to OFF mode.sygonix 1385634 Digital Room Thermostat Operating-fig-14 sygonix 1385634 Digital Room Thermostat Operating-fig-15 sygonix 1385634 Digital Room Thermostat Operating-fig-16

Error messages displaysygonix 1385634 Digital Room Thermostat Operating-fig-17

The display flashes when the room temperature drops be-low 0 °C or climbs above 45 °C.

Maintenance and cleaning

Regularly check the technical safety of the device, e.g. for a damaged casing. If you have reason to believe that the device can no longer be operated safely, disconnect it immediately and make sure it is not operated unintentionally.

It must be assumed that safe operation is no longer possible if:

Always observe the following safety information before cleaning or servicing the device:

Live components may be exposed if cover is opened.
The device must be disconnected from all power sourc-es before any servicing or repair work is carried out. Capacitors inside the device may still carry voltage even though they have been disconnected from all power sources. Only qualified experts familiar with the hazards involved and the relevant regulations must perform repairs.

The product requires no servicing apart from replacing the rechargeable battery. Servicing or repair must only be car-ried out by a specialist or specialist workshop. Therefore, never open it (except for the procedures described in these operating instructions for insertion/replacing the batteries). A dry, soft and clean cloth is sufficient for cleaning. Do not put too much pressure on the display; this can cause scratch marks, failures of the display or even destroy the display. Dust can easily be removed with a long-hair, soft and clean brush and a vacuum cleaner. Never use any aggressive cleaning agents, cleaning alcohol or other chemical solutions, since these may damage the casing (discolouration) or even impair function.

Disposal

Technical data

Display range

Legal Notice

This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). All rights including translation reserved. Reproduction by any method, e.g. photocopy, mi-crofilming, or the capture in electronic data processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication represent the technical status at the time of printing.
© Copyright 2016 by Conrad Electronic SE.
V3_0516_02/VTP
Downloaded from www.Manualslib.com manuals search engine

REFERENCE:

DOWNLOAD MANUALS:

sygonix 1385634 Digital Room Thermostat Operating Instructionssygonix lgoo

sygonix 1385634 Digital Room Thermostat Operating Instructions

Leave a Reply

Your email address will not be published. Required fields are marked *

To respond on your own website, enter the URL of your response which should contain a link to this post's permalink URL. Your response will then appear (possibly after moderation) on this page. Want to update or remove your response? Update or delete your post and re-enter your post's URL again. (Find out more about Webmentions.)