Suntouch 500850 Command Programmable Touchscreen Thermostat Specification
Programmable Touchscreen Thermostat
This all-in-one thermostat includes a built-in relay to control 120 or 240 VAC floor heating systems and a GFCI to improve safety. By default, the SunStat Command controls the floor temperature. It can optionally limit the floor temperature to prevent the space from overheating or be configured to control the space through air temperature alone.
Specifications
Literature | IOM-ST-Command, ES-ST-Command |
Operation Voltage | 120/240 VAC, 60 Hz, 3 watts |
Maximum Load | 15 amps resistive |
Maximum Power | 1800 watts at 120 VAC
3600 watts at 240 VAC |
GFCI | Class A (5 milliamp trip) |
Dimensions | 4-5/8″ H x 2-19/20″ W x 1-13/20″ D (118 x 75 x 42 mm) |
Enclosure | White PVC plastic, NEMA type 1 |
Ambient conditions | 32 to 86°F (0 to 30°C), <90% RH non-condensing |
Floor Sensor | Thermistor, 10k NTC type, 300 V jacketed cable, 15′ long |
Features
- Floor and air sensing control
- Touchscreen display with multiple color themes
- Thin profile with removable, paintable beauty ring
- 7-day programmable schedules
- Energy use monitoring
- Comprehensive help screens
- Home automation system tie-in
- Temporary hold setting
ATTENTION
This Engineering Sheet is not intended to provide full installation instructions and safety information. In order to avoid property damage or injury, please refer to the complete installation manual and product safety information provided with the product.
SunStat Command Application Examples
Typical Wiring for SunStat Command with one mat or cable (120/240 VAC).
Dedicated 120 or 240 VAC, 20-amp (maximum) circuit (maximum 15 amp load through SunStat control)
Typical Wiring for SunStat Command with multiple mats or cables (120/240 VAC).
Dedicated 120 or 240 VAC, 20-amp (maximum) circuit (maximum 15 amp load through SunStat control)
Electrical Wiring Diagram for SunStat Command with SunStat Relay C3 (120/240 VAC). Up to 10 SunStat Relay C3’s can be connected to expand the area controlled by a single SunStat Command.
Dedicated 120 or 240 VAC, 20-amp (maximum) circuit (maximum 15 amp load through SunStat control)
USA: T: (888) 432-8932 • F: (417) 831-4067 • SunTouch.com Canada: T: (905) 332-4090 • F: (905) 332-7068
Latin America: T: (52) 81-1001-8600 • SunTouch.com
© 2019 SunTouch
REFERENCE:
Download Manual
Suntouch 500850 Command Programmable Touchscreen Thermostat Specification Guide
Suntouch 500850 Command Programmable Touchscreen Thermostat Specification Guide
Leave a Reply