SunStat-LOGO

SunStat 108101 Relay C3 Thermostat

SunStat-108101-Relay-C3-Thermostat

Installation and Operation Manual

Features:

Warning 
Please be aware local codes may require this control to be installed or connected by an electrician.

This device complies with Part 15 of the FCC Rules and with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Warning
Read this manual BEFORE using this equipment. Failure to read and follow all safety and use information can result in death, serious personal injury, property damage, or damage to the equipment. Keep this manual for future reference.

Important Safety Information

This is a safety-alert symbol. The safety-alert symbol is shown alone or used with a signal word (DANGER, WARNING, or CAUTION), a pictorial and/or a safety message to identify hazards. When you see this symbol alone or with a signal word on your equipment or in this manual, be alert to the potential for death or serious personal injury.

This pictorial alerts you to electricity, electrocution, and shock hazards.

Warning
This symbol identifies hazards which, if not avoided, could result in death or serious injury.

Caution
This symbol identifies hazards which, if not avoided, could result in minor or moderate injury.

Notice 
This symbol identifies practices, actions, or failure to act, which could result in property damage or damage to the equipment.

Box Contents

Items Needed

Location

Specifications:

Notice
The Relay C3 is only compatible with the SunStat Connect, Relay C3 Command and Core models. Do not connect to older model SunStat thermostats or relays.

Installation

Warning
Installation must be performed by qualified persons, in accordance with local codes, ANSI/NFPA 70 (NEC Article 424) and CEC Part 1 Section 62 where applicable. Prior to installation, please consult the local codes in order to understand what is acceptable. To the extent this information is not consistent with local codes, the local codes should be followed. Regardless, electrical wiring is required from a circuit breaker or other electrical circuit to the control. It is recommended that an electrician perform these installation steps. Please be aware local codes may require this product to be installed by an electrician.

The following cautions must be observed:

Warning
To prevent the risk of personal injury and/or death, make sure power is not applied to the product until it is fully installed and ready for final testing. All work must be done with power turned off to the circuit being worked on. To reduce the risk of electric shock, do not connect to a circuit operating at more than 150 V to ground.

Power Supply

Pull power supply wiring to the relay location.

Warning
Make sure 120 VAC is supplied to 120 VAC cables and 240 VAC is supplied to 240 VAC cables. Otherwise, dangerous overheating and a fire hazard could result. Do not exceed 15-amps on this control.

Bottom Plate Work

Floor Heating Mat or Cable Power Lead Installation

Rough-in Communication Wiring

Relay C3 Wiring

Before connecting the wires to the back of the relay, detach the front from the base. While holding the base section in one hand, pull the lower half of the front towards you to pivot it away from the base.SunStat 108101 Relay C3 Thermostat-fig-4

Using the wire nuts included with the relay:

Connection to the SunStat thermostat and additional relays are made by inserting the wires into the square openings in the terminal block and tightening the screws on the side.

Warning
Make sure the wire connections are secure by gently tugging on them. Otherwise, arcing could occur, causing dangerous overheating and a possible fire hazard. For added security, overwrap each wire nut connection with electrical tape.

Finish Relay Installation

Notice
Make sure the mortar has had time to fully cure before operating the system for more than a brief test.

LED Operation

LED lights on the SunStat Relay C3 indicate operational status.SunStat 108101 Relay C3 Thermostat-fig-7

Operation

Power Up

Heating Operation
The SunStat Relay C3 provides additional capacity for spaces that are larger than a SunStat Connect, Command or Core thermostat can control. The SunStat Relay C3 energizes the connected heating cable any time the thermostat determines heat is required. When the thermostat signals the relay to operate, the Heat Demand light is on.

GFCI Testing and GFCI Light Operation

Power Off

Troubleshooting Guide

It is strongly recommended that a qualified, licensed electrician install the heating cables and related electrical components. If problems with the system arise, please consult the troubleshooting
guide below.

Warning
Any electrical troubleshooting work should be performed with the power removed from the circuit, unless otherwise noted.SunStat 108101 Relay C3 Thermostat-fig-10

WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm.
For more information: Watts.com/prop65

Limited 3 Year Warranty

Watts Radiant warrants this control (the product) to be free from defect in material and workmanship for a period of (3) years from the date of original purchase from authorized dealers. During this period, Watts Radiant will replace the product or refund the original cost of the product at Watts Radiant’s option, without charge, if the product is proven defective in normal use. Please return the control to your distributor to begin the warranty process. This limited warranty does not cover shipping costs. Nor does it cover a product subjected to misuse or accidental damage. This warranty does not cover the cost of installation, diagnosis, removal or reinstallation, or any material costs or loss of use. This limited warranty is in lieu of all other warranties, obligations, or liabilities expressed or implied by the company. In no event shall Watts Radiant be liable for consequential or incidental damages resulting from installation of this product. Some states or provinces do not allow limitations on how long an implied warranty lasts, or the exclusion or limitation of incidental or consequential damages, so the above exclusions or limitations may not apply to you. This warranty gives you specific legal rights and you may also have other rights that vary from state to state.

Watts Radiant Customer Support

USA Toll-free: (800) 276-2419
USA Fax: (417) 864-8161
WattsRadiant.com
Canada Toll-free: (888) 208-8927
Canada Fax: (905) 332-7068
Watts.ca

SunTouch Customer Support
USA Toll-free: (888) 432-8932
USA Fax: (417) 831-4067
Canada Toll-free: (888) 208-8927
Canada Fax: (905) 332-7068
Latin America Tel: (52) 81-1001-8600
Latin America Fax: (52) 81-8000-7091
SunTouch.com

Reference

Download Manual:

SunStat 108101 Relay C3 Thermostat Installational Manual

OTHER MANUALS

SunStat 108101 Relay C3 Thermostat Product Specifications Guide

SunStat-LOGO

SunStat 108101 Relay C3 Thermostat Installational Manual

Leave a Reply

Your email address will not be published. Required fields are marked *

To respond on your own website, enter the URL of your response which should contain a link to this post's permalink URL. Your response will then appear (possibly after moderation) on this page. Want to update or remove your response? Update or delete your post and re-enter your post's URL again. (Find out more about Webmentions.)