INTRODUCTION

Your new 44-850 is a feature-rich touchscreen thermostat has been manufactured using the highest quality components and design currently available. When properly installed and configured by a professional heating and air conditioning contractor, the 44-850 will provide years of dependable operation The 44-850 has been designed to be an attractive, highly reliable and easy-to-use thermostat. By taking time to read and understand this User Manual, you can take advantage of the many features offered in this premium product Although great care has been taken in the preparation of this manual, Smart Temp takes no responsibility for errors or omissions contained herein. It is the responsibility of the installer to ensure that this thermostat and the equipment connected to it operate in a safe and efficient manner.

USING THE TOUCHSCREEN DISPLAY

To simplify use, the 44-850 only displays information relevant to the current mode of operation. When adjustments are required, the thermostat will display additional information or functional icons. Based on the thermostat configuration, some information and icons may not be displayed. The illustration below shows all the LCD segments and icons along with abbreviated definitions

Smarttemp- 44-850- Touchscreen- Thermostat- 1

TYPICAL DISPLAY

  • Day of the week
  • Time of day
  • Calendar
  • Space temperature
  • Fan selection
  • Program period (programmable mode only)
  • Mode of operation
  • Set temperatureSmarttemp- 44-850- Touchscreen- Thermostat- 2

SETTING THE DAY, TIME AND CALENDAR
Touch the display to bring on the backlight then touch and hold the clock with your finger. The thermostat will beep. The hour will flash. Touch the UP or DOWN arrow to change the hour making sure that AM or PM are correct. Touch the clock again and the minutes will flash. Touch the UP or DOWN arrow and change the minutes and then touch the clock. The calendar day will flash. Touch the UP or DOWN arrow to change the day then touch the clock. The day of the month will flash. Touch the UP or DOWN arrow to change the day of the month and then touch the clock. The year will flash. Touch the UP or DOWN arrow to change the year and then touch the clock. After a few moments, the thermostat will return to its operating mode.Smarttemp- 44-850- Touchscreen- Thermostat- 3

BASIC FUNCTIONS

MODE CONFIGURATIONS
Your contractor can configure the thermostat with different mode selections based on user preference and/or equipment type. Mode configurations can be as follows:

CONVENTIONAL HEATING AND COOLING EQUIPMENT (GAS/ELECTRIC)

  • Manual Changeover (Heat/Cool/Off)
  • Auto Changeover (Heat/Cool/Auto/Off)
  • Heat Only (Heat/Off)
  • Cool Only (Cool/Off)

HEAT PUMP AND FOSSIL FUEL EQUIPMENT

  • Manual Changeover (Heat/Cool/*E.Heat/Off)
  • Auto Changeover (Heat/Cool/Auto/*E.Heat/Off)
  • Heat Only (Heat/*E.Heat/Off)
  • Cool Only (Cool/Off)

MODE SELECTION
To select a mode of operation, simply touch the Mode box on the screen. Based on the equipment and thermostat configuration, mode selection can be as follows

  • Off – The thermostat will not call for heating or cooling.
  • Heat – The thermostat will only call for heating.
  • Cool – The thermostat will only call for cooling.
  • Auto – The thermostat will call for both heating and cooling.
  • E. Heat – Thermostat only controls emergency heat when configured for heat pump or fossil fuel equipment.Smarttemp- 44-850- Touchscreen- Thermostat- 4

FAN SELECTION
Touch the Fan box on the screen to select Automatic or Always On fan mode. In Automatic mode, the fan operates with a heating or cooling call. If set to Always On, the fan will run continuously. If the thermostat is turned Off while the fan is set to Always On, the fan will continue to run until it is placed in the Automatic mode

PROGRAMMABLE FAN (OPTION)
If your thermostat has been configured for Programmable Fan, you can change the fan mode for each scheduled program event. For example, you might wish to have Always On for the morning schedule and Automatic for the Day schedule. Each time the thermostat changes schedules, the selected fan mode will automatically be implemented. (See Page 18 for further details)Smarttemp- 44-850- Touchscreen- Thermostat- 5

Manual Heat/Cool Mode
In manual changeover mode, only the heating or cooling temperature setting will be displayed. To change the setting, simply touch the temperature displayed on the screen. Depending on the mode, either Heat Set or Cool Set will flash. Touch the UP or DOWN arrow to change the setting. Touch the temperature display again or wait 10 seconds and the thermostat will return to its operating mode. The new set temperature will be displayed.Smarttemp- 44-850- Touchscreen- Thermostat- 6

Auto Mode
In auto changeover mode, the heating and cooling temperature setting alternate on the screen. To change the settings, simply touch the temperature displayed on the screen. Cool Set will flash three times and then Heat Set will flash three times To change the cooling setting, touch the UP or DOWN arrow to change the setting when Cool Set is flashing. To change the heating setting, touch the UP or DOWN arrow to change the setting when Heat Set is flashing. Touch the temperature display and the thermostat will return to its operating mode, or simply wait for 10 seconds to auto exit set point adjustment. The new heating and cooling temperatures will alternately be displayedSmarttemp- 44-850- Touchscreen- Thermostat- 7

PROGRAMMING

7-DAY SCHEDULE (4 OR 2 DAILY EVENTS)
Your installer can configure the 44-850 with two programming options for 7-day scheduling. You can elect to have 4 daily events (Morning, Day, Evening, Night) or 2 daily event (Day, Night) for each day of the week. You can program both heating and cooling temperatures for each scheduled event when the thermostat is in the Auto (auto changeover) or manual changeover (Heat, Cool) mode. The thermostat can not be programmed in the Off mode. If the thermostat is configured for heat only or cool only, then only that mode can be programmed. Simply touch Mode to select Auto, Heat or Cool. At any time you wish to exit programming mode touch and hold the lower right of the display (where the mode would normally be shown). Your installer can configure the 44-850 with two programming options for 7-day scheduling. You can elect to have 4 daily events (Morning, Day, Evening, Night) or 2 daily event (Day, Night) for each day of the weekSmarttemp- 44-850- Touchscreen- Thermostat- 8

DAILY EVENTS
Press and hold Program. Mon (Monday) along with the UP and DOWN arrows will appear on the screen.Smarttemp- 44-850- Touchscreen- Thermostat- 9

  • Touch Program again and the Morning start time will appear. The hour and AM or PM will flash.
  • Touch the UP or DOWN arrow to change the Morning start time hour. The factory default is 6:00 AM.
  • Touch Program again and the minutes will flash. Touch the UP or DOWN arrow to change the minutes which can be adjusted in 10 minute increments
  • Touch Program again and the Morning Cool Set temperature will be displayed and flash Smarttemp- 44-850- Touchscreen- Thermostat- 10
  • UP or DOWN arrow to change the cooling temperature. The factory default if 25° for the morning schedule.
  • Touch Program again and the Morning Heat Set temperature will be displayed and flash.
  • Touch the UP or DOWN arrow to change the heating temperature. The factory default is 21
  • Touch Program again and the Day start time will appear. The hour will flash along with AM or PM.Smarttemp- 44-850- Touchscreen- Thermostat- 10
  • Follow the same steps as in the Morning sequence. The factory defaults for the Day event are 8:00 AM, Cool Set 25°, Heat Set 16° F.
  • After setting the Day Heat Set temperature, touch Program again and the Evening start time will appear. Follow the same steps. The factory defaults for the Evening event are  6:00 PM, Cool Set 24°, Heat Set 21° F.
  • After setting the Evening Heat Set temperature, touch Program again and the Night start time will appear. Follow the same steps. The factory defaults for the Night event are 10:00 PM, Cool Set 25°, Heat Set 16°.
  • Touch Program again and the word cpy (copy) will appear. If you want to copy the Monday schedule to consecutive days of the week, touch the UP arrow to add additional days. Each day that you select will flash. For example, you might want to copy the Monday schedule to Tuesday and Wednesday. Once Tue and Wed are flashing, touch Program and cpy will flash confirming that the Monday schedule is being copied to Tuesday and Wednesday. The thermostat will then advance to Thu (Thursday).
  • If you elect to have a different schedule for each day of the week, simply touch Program when cpy appears. The thermostat will automatically advance to the next day
  • If you elect to have a different schedule for each day of the week, simply touch Program when cpy appears. The thermostat will automatically advance to the next day.Smarttemp- 44-850- Touchscreen- Thermostat- 12

2 DAILY EVENTS
Seven day scheduling for 2 daily events uses the same programming steps as 4 daily events other than you only have to program Day and Night. Once programming is completed, the thermostat will resume normal operation in 10 seconds.

PROGRAMMABLE FAN
If your installer has configured the 44-850 with the Programmable Fan Option, you will be able to select Automatic or Always On fan with each programmed event. When programming the thermostat, the Programmable Fan Option will appear at the end of each programming event. When the word Automatic begins to flash, touch the UP arrow to change to Always On or simply touch Program to maintain Automatic fan operation for the program period. Just like Temporary Temperature Override, the fan mode can be changed simply by touching Fan. The program event will flash confirming the Programmable Fan mode is in override. To resume normal operation, touch Program. Hold will appear. Touch Hold and the thermostat will resume programmed operation Automatic fan mode allows the equipment fan to run whenever there is a call for heating or cooling. Always On fan mode allows the fan to run continuously with or without a call for heating or cooling.

OVERRIDES

When the 44-850 is configured for programmable operation, there are two types of temperature overrides available

TEMPORARY TEMPERATURE OVERRIDE ( 2 Hours Fixed)
Temporary Temperature Override is designed to allow you to adjust the heating or cooling temperature without affecting the programmed temperatures. For example, if you want to change the heating temperature, simply touch the displayed temperature. When Heat Set flashes, touch the UP or DOWN arrows to adjust the setting. The thermostat will resume normal operation in 10 seconds and display the new heating temperature. The program period (Morning, Day, Evening, Night) or (Day, Night) will flash continuously to provide confirmation that the temperature has been changed. The new heating temperature will remain active for 2 hours, after this period it will be deleted and will return to your programmed temperature schedule. To manually cancel Temporary Override, touch Program until Hold appears and then touch Hold. The thermostat will resume normal programmed operation and the override period will stop flashingSmarttemp- 44-850- Touchscreen- Thermostat- 13

PERMANENT HOLD
There may be times when a permanent override is required such as during a vacation or holiday period. To place the thermostat in Permanent Hold, simply touch Program and the word Hold will appear. Next, touch the displayed temperature. While Set Heat or Set Cool are flashing, touch the UP or DOWN arrow to adjust the permanent hold temperature(s) that you want to maintain. Whenever you want the thermostat to resume normal programmed operation, simply touch Hold. Program will again appear and the thermostat will resume programmed operation.

OTHER OPTIONS AND FEATURES

ADAPTIVE RECOVERY OPTION
If your thermostat has been configured for programmable operation, your installer can add the Adaptive Recovery Option. Adaptive Recovery compares the space temperature deviation from the set temperature for the next scheduled event and rate of recovery history to bring the equipment on and reach the next temperature setting at the scheduled event start time. Example: If you program a heating temperature to be 21 degrees at 6:00 PM, Adaptive Recovery will calculate when to bring the equipment on so that the temperature will be 21 degrees at 6:00 PM.

CLEAN SCREEN
It is recommended that the touch screen be cleaned periodically. Use a slightly moistened clean, nonabrasive cloth. Touch the screen until the LCD lights up. Touch the Clean Screen window. All normal operating functions will be hidden and locked. The thermostat will count down from 15 seconds while you clean the screen. If more time is required, simply touch the Clean Screen box againSmarttemp- 44-850- Touchscreen- Thermostat- 14

LOW BATTERY INDICATION
Your thermostat uses two AA batteries to keep the time-of-day clock running in case of a power failure. In some applications, battery power is also used to control the heating and air conditioning equipment. When the Low Battery icon appears on the screen the back light is disables, you should change the batteries immediately. If the batteries are not changed and the batteries become weaker, the display will blank completely and the beeper will chirp every minute (Between 8:00am and 9:00 pm only) to remind you to change the batteries.Smarttemp- 44-850- Touchscreen- Thermostat- 15

CHANGING THE BATTERIES

Press in on the battery access compartment, it will pop out a small way. Slide the drawer out. Install two AA ALKALINE batteries matching the + (Positive) and – (Negative) orientation. Push the battery compartment in until it clicks shut. When the batteries are properly installed, the touchscreen display will resume normal operation with no loss of programming. If the batteries are swapped out quickly (less then 5 minutes) the current time will remain unaffected.

NOTE: Use fresh Alkaline batteries only. Do not use rechargeable, super heavy duty or any other type of battery other than Alkaline or erratic operation may resultSmarttemp- 44-850- Touchscreen- Thermostat- 16

SMART TEMP

www.thermostat.com.au

REFERENCE:

DOWNLOAD MANUALS:

Smarttemp 44-850 Touchscreen Thermostat User Manual

OTHER MANUALS:

Smarttemp 44-850 Touchscreen Thermostat Installer Manual

Smarttemp logo

Smarttemp 44-850 Touchscreen Thermostat User Manual


Posted

in

by

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *

To respond on your own website, enter the URL of your response which should contain a link to this post’s permalink URL. Your response will then appear (possibly after moderation) on this page. Want to update or remove your response? Update or delete your post and re-enter your post’s URL again. (Find out more about Webmentions.)