SIEMENS REV13 Room Thermostat
REV13.. – the 24-hour room temperature controller for the right temperature at the right time. The REV13… offers you 2 individually selectable and adjustable switching patterns. All factory settings already provide optimal living comfort. You can easily adjust the controller to your individual needs with the user-assisted clear-text display and program selection slider.
Note the following when placing the controller:
Make sure no other influencing factors adversely affect the controller’s temperature sensor (no direct solar radiation and no influence from other heat or refrigeration sources).
DISPLAY
Operating instructions
If the selected operating mode does not support the setting, the time display shows PASS.
Special symbols displayed
The controller display can show the following special symbols:
Is symbol displayed?
- The alarm indicates an error!
- Press the Info button and check the error message (e.g. radio clock signal, radio link to receiver, etc.). Contact a specialist if required.
RED regulation
Siemens Switzerland Ltd. declares that the radio equipment type REV13.. is in compliance with Directive 2014/53/EU. The full text of the EU declaration of Conformity is available at
www.siemens.com/download?A6V10223310.
Is the symbol displayed?
This symbol tells you that you must replace the batteries within the next 3 months.
Insert 2 new alkaline batteries type AAA, 1.5 V as follows:
- Remove the controller from its mounting base; open the battery compartment at the rear; remove the old batteries; insert the new batteries; close the battery compartment and reinsert the controller in its base.
Caution: Time of day and date are retained for 1 minute. (All other settings are fixed and remain unchanged!) - Dispose of the old batteries as per regulations.
Is symbol displayed?
The radio clock symbol only appears if the receiver is set up and activated to receive the time signal from Frankfurt (Germany). A permanent symbol indicates that both time of day and date of the controller are synchronized to the Frankfurt radio clock (DCF77). The symbol blinks if the time signal is not received for more than 1 week
Commissioning the controller and quick start
The controller contains a factory-set switching pattern and temperature values.
For initial commissioning, proceed as follows
![]() |
Remove the controller from its mounting base and pull off the black transit tab from the 2 batteries: The controller turns on automatically. Reinsert the controller in its mounting base. |
![]() |
After startup, a welcome message appears for about 2 minutes. Press any of the buttons to interrupt the running display. Language selection starts with
“ENGLISH“ (factory setting). Press Press or move the slider to confirm your language. |
![]() |
Slider in position 1 (time setting): Press ![]() ![]() Note: You do not need to enter the time of day when the DCF77 receiver for the time signal from Frankfurt (Germany) is fitted. |
![]() |
Slider in position 2 (date: day – month – year): Press ![]() ![]() Note: You do not need to enter the date when the DCF77 receiver for the time signal from Frankfurt (Germany) is fitted. |
RUN | Move the slider to the very right to position RUN (only way to close the cover). |
![]() |
Select the operating mode with the operating mode selector. Factory setting is
. |
Fold the operating instructions again and reinsert them in the mounting base. Turn on display lighting, check error messages or other important information
Turn on display lighting, check error messages or other important information
- Press the Info button once to activate display backlighting. Backlighting goes off automatically after a short time.
- Continuing to press the Info button activates the info display: is lit.
- The controller first shows pending error messages and then important information (e.g. switching programs, etc.).
Change the temperature level in the time switch program, or are you not at home for a while?
- In the time switch program, press this button to change from the current temperature level to the next and back.
- Quickly activate the energy saving temperature when you leave the apartment for a short time to save energy.
- The change appears on the display. It is valid only until the next switching time.
Tips to save energy without sacrificing comfort
- Heat your rooms to max. 21 °C
- Press
to switch to energy saving temperature even if you are absent only briefly
- Air out your rooms briefly, but windows wide open
Select operating mode
Press the operating mode button to select one of 5 modes
Operating modes with time program
The controller offers 2 time programs: and
.
Do you feel too warm / too cold?
Press or
to set the required temperature. The setting is temporary and active only until the next time the controller activates a change
Note: To set your own time programs, refer to section “Enter customized temperatures and switching times“.
Continuous operating modes
The controller offers the continuous operating modes “Continuously Comfort mode” , “Continuously Energy Saving mode“
and “Frost Protection mode“
.
Do you feel too warm / too cold?
Press or
to set the required continuous temperature
Enter time of day and date
![]() |
Slider in position 1 (time setting): Press or to set the correct time of day. |
![]() |
Slider in position 2 (date: day – month – year): Press or to set the date. |
RUN | Reset the slider to the RUN position. |
Note: You do not need to enter the time of day and the date when the DCF77 receiver for the time signal from Frankfurt (Germany) is fitted. The time display shows PASS
Enter customized temperatures and switching times
The controller offers 2 Automatic modes and
that you can set with the program selector slider.
Proceed as follows:
![]() |
Slider in position 3 (start time 1 for Automatic mode with 2 heating phases): Press or to set the required start time. |
![]() |
Slider in position 4 (end time 1 for Automatic mode with 2 heating phases): Press or to set the required end time. |
![]() |
Slider in position 5 (start time 2 for Automatic mode with 2 heating phases): Press or to set the required start time. |
![]() |
Slider in position 6 (end time 2 for Automatic mode with 2 heating phases): Press or to set the required end time. |
![]() |
Slider in position 7 (start time for Automatic mode with 1 heating phase): Press or to set the required end time. |
![]() |
Slider in position 8 (end time for Automatic mode with 1 heating phase): Press or to set the required end time. |
![]() |
Slider in position 9 (comfort temperature for Automatic mode A and B): Press or to set the required comfort temperature. |
![]()
|
Slider in position 10 (energy saving temperature for Automatic mode A and B): Press or to set the required energy saving temperature.
Note: The energy saving temperature in time programs A and B is independent of the energy saving temperature in operating mode “Continuously Energy Saving mode“. |
RUN | Move slider back to the RUN position and close the cover. |
Enter temperature for active remote control
With active remote control, you are free to select the temperature. Activating remote control immediately enables control to the remote operating temperature regardless of the current operating mode. After you switch off remote control, the controller returns to the selected operating mode
Symbol blinks with active remote control
Proceed as follows
![]() |
Slider in position 11 (temperature for active remote control: Press or to set the temperature for active remote control. |
RUN | Move slider back to the RUN position. |
Reset to factory settings
Press
and
together with the operating mode button
for 3 seconds. All temperature and time settings are reset to their default values.
The clock starts at 12:00.
Caution: All customized settings will be lost
Factory settings: Heating | ||
![]()
|
![]() |
20 °C |
![]() |
16 °C | |
![]() |
8 °C | |
![]() |
12 °C |
Factory settings: Switching times | ||||
![]() |
A1 | A2 | A3 | A4 |
06:00 | 08:00 | 17:00 | 22:00 |
![]() |
B1 | B2 |
07:00 | 23:00 |
Activate Party mode
You can activate Party mode only in operating modes and
. In Party mode, the unit controls to any selectable temperature for any selectable time.
In Party mode, symbol is displayed along with the end of Party mode.
Proceed as follows:
- Press
for 3 seconds.
- Press
or
to set the duration of Party mode. Party mode can last a maximum of 9 hours. The entry is confirmed after 20 seconds or when you press
.
- Press
or
to set the required temperature.
- Party mode ends automatically after the party duration ends or when you press
or
.
Notes (e.g. customized settings):
REFERENCE:
DOWNLOAD MANUALS:
SIEMENS REV13 Room thermostat Operating Instruction
OTHER MANUAL:
SIEMENS REV13 Room Thermostat Production Specifications Guide
Leave a Reply